Asurity ULTRACP-22 Condensate Pump Ultra Instruction Manual
- June 1, 2024
- Asurity
Table of Contents
Asurity ULTRACP-22 Condensate Pump Ultra
Specifications
- Rated Voltage: ULTRACP-22: 120 Volts/60Hz, ULTRACP-22-230: 230 Volts/60 Hz
- Rated Current Draw: ULTRACP-22: 1.9 Amps, ULTRACP-22-230: 1.0 Amps
- Head Height: 22 ft. maximum
- Flow Rate at Zero Head: ULTRACP-22: 1.6 GPM, ULTRACP-22-230: 1.0 GPM
- Product Weight: 5 lbs.
- Inlet Height from Base: 4.4 in.
Product Information
- This Condensate Pump Ultra is designed to automatically remove condensate water collected from appliances like air conditioners and de-humidifiers. It features a built-in tank that collects water and pumps it to a remote location for disposal when the water level reaches a certain point.
- The pump can lift water up to 22 ft. and includes a check valve to prevent water from flowing back into the tank. LED indicator lights display Power Available, Motor Running, and High Water (Alarm) Conditions. An overflow safety switch can be connected to turn off the appliance in case of a high water condition.
Product Usage Instructions
Installation
- Ensure power is disconnected before moving, adjusting, or servicing the pump.
- Avoid using the pump in the presence of spraying or standing water to prevent electric shock.
- Mount the pump away from heat sources or wiring to avoid fire hazards.
- If unsure about installation, consult a professional before proceeding.
Operation
- Ensure the pump is properly connected to the appliance and power source.
- Monitor the LED indicator lights to check the pump status.
- If an overflow condition is detected, investigate and address the cause promptly.
- Regularly check and maintain the pump to ensure proper functioning.
Frequently Asked Questions (FAQ)
-
Q: What should I do if the pump does not switch on automatically?
A: Check the power connection and ensure the tank has sufficient water level to trigger the switch. -
Q: How often should I clean the pump?
A: It is recommended to clean the pump regularly, at least once every few months, to prevent clogs and maintain efficiency.
INTRODUCTION
SAFETY INFORMATION
Please read, understand, and follow all safety instructions. Failure to follow
instructions may result in property damage, serious injury, or death.
DANGER
ALWAYS disconnect power prior to moving, adjusting, or servicing pump or
attached systems. DO NOT use this pump in the presence of spraying or standing
water. Failure to do so could result in a fatal electric shock.
WARNING: FIRE AND EXPLOSION HAZARD
- DO NOT use this pump to move flammable or explosive liquids.
- DO NOT use this pump in explosive or flammable environments. Carbon monoxide hazard. Ensure that pump is mounted away from heat exchanger or wiring. If you are unsure of any items in this manual, please consult a professional and DO NOT attempt to install this product.
CALIFORNIA PROPOSITION 65
- This product may contain chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling this product.
CAUTION: FLOOD RISK
- Personal injury or property damage can result from an inoperative pump. If a flood has occurred, DO NOT walk in wet area until all power has been turned off. Check with local electric company or a qualified electrician before disconnecting any electrical service prior to pump removal.
WARNING
- Supply voltage and frequency must match what is shown on pump nameplate. Source voltages lower than the rated supply can reduce performance and cause pump to overheat.
- Pump must be level and should be mounted to or placed on a solid surface or floor.
- DO NOT cover pump air vents. Pump is air cooled. DO NOT cover vent holes located on top or sides of the pump housing. Pump may be operated continuously as long as air vents are not covered.
- Pump should be stored indoors. The chosen location should be clean and dry.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WATER TEMPERATURE RATING (NOT TESTED FOR HOT WATER)
- Continuous duty 140˚F
- Max inlet temperature 160˚F
- Not suitable for contact with steam or gases that exceed 160˚F
GENERAL INFORMATION
This pump is designed to automatically remove the condensate water that
collects from appliances such as air conditioners and de-humidifiers. The pump
has a built-in tank that collects water from the appliance. When water
collected reaches sufficient level inside pump tank, pump switches on and
pumps water to a remote location for disposal. When tank is sufficiently
empty, pump automatically switches off. Pump is capable of lifting water up to
22 ft. and is equipped with a check valve that prevents water from flowing
back into tank when pump shuts off. The pump utilizes LED lights that show the
status of Power Available, Motor Running, and High Water (Alarm) Conditions.
Pump is also equipped with a switch that activates when water in tank reaches
an overflow condition. The overflow safety switch may be connected to turn off
the appliance if high water condition occurs.
FEATURES
PACKAGE CONTENTS
SPECIFICATIONS
**INSTALLATION
**
MOUNTING OPTIONS
-
A. PLACE ON FLOOR
Determine condensate pump location. -
B. ATTACH TO WALL
Attach condensate pump with screws (8 in. between mounting tabs). -
OPTION: REVERSE TOP IF NECESSARY
Pump top may be rotated 180˚ to allow access to pump outlet or power connection.
LEVEL UNIT
- Ensure that condensate pump is level.
OUTLET CONNECTIONS
INSTALL OUTLET TUBE CONNECTION
- Attach plastic tubing to check valve and secure with hose clamp. Route tubing up and away from condensate pump (avoid compressing or kinking tubing).
INLET CONNECTIONS
INSTALL INLET TUBE CONNECTIONS
- Install condensate drain tubing into one of the four inlet holes, making sure tubing is straight.
- If installing to a humidifier, a “P” trap should be used.
INLET COVERS
INSTALL INLET COVERS
- Insert inlet covers in remaining condensate pump inlet holes.
SAFETY SWITCH CONNECTION
- Connect overflow safety switch terminals as shown in wiring diagram.
WARNING : RISK OF ELECTRIC SHOCK
Ensure that power to appliance and pump is shut off before attempting this
step! Failure to follow these warnings will void the warranty and could result
in a fatal electric shock.
ELECTRICAL CONNECTION
WARNING: RISK OF ELECTRIC SHOCK
- This pump is supplied with a grounding conductor and grounding-type attachment plug.To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. This pump must be properly connected to power following the National Electric Code (NEC). Failure to follow these warnings will void warranty and could result in a fatal electric shock. A green LED will indicate if power is available.
- This pump is supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
Plug Note : Removal of the wall side electrical plug may be permissible if:
- The power leads, after plug removal, are connected directly within an approved junction or conduit box, as judged by the local authority having jurisdiction.
- The modification is performed by a qualified technician.
- The modification meets code compliant requirements according to the local authority.
This modification does not void the factory warranty. Final installations
should always be inspected and approved by the local authority according to
the requirements set forth by
the same local authority.
OPERATION
TESTING FLOAT
Manually fill the tank with water. An amber LED will indicate pump is
operating.
TESTING OVERFLOW SWITCH (IF CONNECTED)
Manually overfill tank with water. If overflow safety switch is wired
correctly, appliance will shut down, condensate pump will pump out water, and
a red LED will illuminate.
LED INDICATOR STATUS
MAINTENANCE AND DISASSEMBLY
ALWAYS disconnect power before performing maintenance. Pump and deck may be
removed from tank by pushing tabs located on tank sides away from deck while
lifting on pump cover.
Periodically inspect the condensate pump tank to ensure it is free of
accumulated dirt or sludge. DO NOT use solvent cleaners. Clean tank with soap
and warm water only. Check valve may be removed for cleaning or replacement by
unscrewing with a 5/8” wrench.
Clean inlet and outlet piping. Reassemble system and check for correct operation.
TROUBLESHOOTING
www.diversitech.com | 800.995.2222
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>