AICKSN RO400G Central Reverse Osmosis Water Filtration Systems User Manual
- June 2, 2024
- AICKSN
Table of Contents
- AICKSN RO400G Central Reverse Osmosis Water Filtration Systems
- Product Specifications
- Product Usage Instructions
- Introduction
- System includes
- Product specification
- Installation instruction
- Component description drawing
- Special Note
- TROUBLE SHOOTING
- WARRANTY SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AICKSN RO400G Central Reverse Osmosis Water Filtration Systems
Product Specifications
- 400G: Rated voltage: 110-220V 50-60Hz, Output voltage: 24V / 3A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/4, Water outlet pipe size: 3/4 to 1/4, Rated flow: 1/4 1L/M
- 600G: Rated voltage: 110-220V 50-60Hz, Output voltage: 24V / 3A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/4, Water outlet pipe size: 3/4 to 1/4, Rated flow: 1/4 1.5L/M
- 1000G: Rated voltage: 110-220V 50-60Hz, Output voltage: 24V / 3A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/4, Water outlet pipe size: 3/4 to 1/4, Rated flow: 1/4 2L/M
Product Usage Instructions
Installation Instructions:
Follow the steps below for installation:
- Refer to the installation instructions provided in the user manual.
- Ensure all components are included in the package.
- Install the RO host and membranes according to the provided flow chart.
- Connect the necessary pipes and valves as indicated in the diagram.
- Adjust the wastewater control valve based on the provided guidelines.
Filter Service Life:
It is recommended to change the filters as follows:
- 1st Stage PP filter: Every 5~8 months
- 2nd Stage ACF filter: Every 6~12 months
- 3rd Stage RO Membrane: Every 2~3 years
- 4th Stage Post carbon filter: Every 6~12 months
Purification Flow Chart:
Follow the flow chart provided in the user manual for proper purification
process.
Troubleshooting:
If you encounter any issues with the system, refer to the troubleshooting
section in the manual for guidance.
FAQ:
-
Q: How often should I change the RO membrane?
A: The RO membrane should be changed every 2-3 years for optimal performance. -
Q: What is the water inlet pressure requirement?
A: The water inlet pressure should be between 0.15-0.4Mpa for effective filtration.
INSTALLATION & SERVICE MANUAL
(AICKSN Central Reverse Osmosis Water Filtration Systems )
- U.S. AICKSN Technology Co.,Ltd.
- Address:250 w clifton st tampa,FL.33614
- Fujian Aicksn Environmental Technology Co., Ltd.
- Tel: 0086 0592-5776975 0086 0592-5569172
- Email: www.aicksn.com
- National Unified Hotline: 400-615-5998
(Commercial Central Filtration System Manual Instruction)
Introduction
Thank you for choosing AICKSN Reverse Osmosis Water Systems. You now own a superb Reverse Osmosis (RO) system that adopts the international advanced reverse osmosis membrane (RO membrane) as the core, and With multi-stage pretreatment filtering, the filtering accuracy reaches 0.0001 micron, effectively reducing most contaminants, organic and inorganic compound, unwanted taste and odor from tap water. It is designed to transform your tap water into distill water. The entire water production process is fully automatic.
System includes
400G | 600G | 1000G |
---|---|---|
RO host 1pc | RO host 1pc | RO host 1pc |
RO membrane 1pc | RO membrane 1pc | RO membrane 1pc |
PP cotton filter 1pc | PP cotton filter 1pc | PP cotton filter 1pc |
ACF filter 1pc | ACF filter 1pc | ACF filter 1pc |
CB carbon filter 1pc | CB carbon filter 1pc | CB carbon filter 1pc |
Parts kit 1pc | Parts kit 1pc | Parts kit 1pc |
User manual 1pc | User manual 1pc | User manual 1pc |
Stainless steel faucet 1pc | Stainless steel faucet 1pc | Stainless steel faucet |
1pc
3/8” PE pipe 2m| 3/8” PE pipe 2m| 3/8” PE pipe 2m
1/4” pe pipe 4m| 1/4” pe pipe 4m| 1/4” pe pipe 4m
Three way ball valve 1pc| Three way ball valve 1pc| Three way ball valve 1pc
Adaptor 1pc| Adaptor 1pc| Adaptor 1pc
Hose connector (3/4” to 3/8”) 1pc| Hose connector (3/4” to 3/8”) 1pc| Hose
connector (3/4” to 1/2”) 2pc
Hose connector (3/4” to 1/4”) 1pc| Hose connector (3/4” to 1/4”) 1pc|
L-shaped elbow 2pc| L-shaped elbow 2pc| L-shaped elbow 2pc
Red buckle 2pc| Red buckle 2pc| Red buckle 2pc
Silicone oil 1 pack| Silicone oil 1 pack| Silicone oil 1 pack
Product specification
| 400G| 600G| 1000G
---|---|---|---
Rated voltage| 110-220V 50-60Hz| 110-220V 50-60Hz| 110-220V 50-60Hz
Output voltage| 24V / 3A| 24V / 3A| 24V / 3A
Water inlet pressure| 0.15-0.4Mpa| 0.15-0.4Mpa| 0.15-0.4Mpa
Water inlet requirement| Municipal water| Municipal water| Municipal water
Water inlet temperature| 5-45℃| 5-45℃| 5-45℃
Water inlet pipe size| 3/4” to 1/4”| 3/4” to 1/4”| 3/4” to 1/4”
Water outlet pipe size| 3/4” to 1/4”
3/4” to 3/8”| 3/4” to 1/4”
3/4” to 3/8”| 3/4” to 1/4”
3/4” to 3/8”
Wastewater pipe size| 1/4”| 1/4”| 1/4”
Rated flow≥| 1L/M| 1.5L/M| 2L/M
Flushing method| Automatic flushing| Automatic flushing| Automatic flushing
Wastewater ratio| Manual adjustable| Manual adjustable| Manual adjustable
Filter Service Life
- 1st Stage PP filter : Recommend changing every 5~8months.
- 2nd Stage ACF filter: Recommend changing every 6~12 months.
- 3rd Stage RO Membrane : Recommend changing every 2~3 years.
- 4th Stage Post carbon filter : Recommend changing every 6~12 months
Installation instruction
-
Preparations before installation
Confirm the installation position of the water purifier, the power supply, and the concentrated underwater water pipe [The installation should depend on the time situation] Confirm that all accessories required for installation are complete. [Refer to the packing list for details] Close the water inlet valve before installation. -
Installation steps:
-
Connect the filter to the corresponding connector of the host;
-
Connect the RO membrane wastewater pipe into the wastewater inlet under the accessories box
-
Connect the 1/4” PE pipe to the host wastewater, and connect the other end of the 1/4” PE pipe to the sewer pipe.
Machine debugging:
After confirming that the water connection is correct, open the water inlet
three-way ball valve [confirm whether there is tap water supply], and plug it
in power supply [confirm whether the socket has electricity], at this time the
high-pressure pump starts, the waste water outlet starts to drain, after
entering the water production state, there will be a small amount of white
protective liquid when the water purifier tap is turned on for the first time,
and the water will be kept for 3-10 minutes until there is no white protective
liquid. The TDS data will be slightly higher when the pure water machine is
used for the first time, and it is necessary to continue to discharge the
water to make the machine produce water flow to about 50-100 liters.
Purification flow chart
Component description drawing
Back of component description drawing
Special Note
Please read the “Instruction Manual” repeatedly before using this water purifier, and strictly follow the requirements in the manual for installation, use and maintenance. If the user fails to install, use and maintain as required and cause an accident, our company will not bear any responsibility for this.
- The main connecting parts of this machine are plastic products. The user must always observe its integrity during use to ensure safe use. When the user goes out for a long time or does not use the machine, be sure to close the water inlet valve, disconnect the power supply, and discharge all the pure water from the pressure tank.
- The machine should not be placed in an excessively humid place, otherwise it will cause spots on some metal parts of the machine.
- The recommended replacement cycle of various filter elements in this machine is calculated by referring to the average index of tap water in the scope of use that meets the national standard. If the water quality at the user’s actual use differs greatly from the average index, there will be a significant difference between the actual use state and the estimated period (such as premature clogging of the filter element, premature failure, etc.). At this time, filter elements replace should be based on the actual use state.
- The estimation of the life cycle is based on ordinary household water. Users with a large water consumption such as units will quickly reach the total water intake. Please replace the filter as soon as possible.
TROUBLE SHOOTING
NOTE: Turn off the system before servicing.
PROBLEM | POSSILE CAUSE | SULUTION |
---|---|---|
The machine does not start | The power is not turned on | Check the power supply |
or the power plug
The high voltage switch cannot be reset| Measure its resistance after
releasing the pressure and replace it
Transformer burns out| Measure its output voltage and replace it
The computer box has no output voltage| Measure its output voltage and replace
it
The high-pressure pump works normally but cannot produce water| Pressure loss
of high-pressure pump| Measure the outlet pressure of the pump and replace it
The four-sided valve is faulty and cannot enter water(there is no pure water
or wastewater)| Replace the four-sided valve
The pre-filter is blocked| Observe the pure water and waste water, and replace
the pre-filter
RO membrane is blocked| Clean or replace RO membrane
PROBLEM| POSSILE CAUSE| SULUTION|
---|---|---|---
The pressure bucket is full, but the pure water cannot flow out| The pressure
bucket is released| Inflate to the pressure bucket, pressure of the empty
bucket is 0.5~0.7KG|
Inline carbon filter is blocked| Replace it|
| The pressure of the| |
| high-pressure pump is less than 3KG, pure water tank| Measure the water
pump|
| pressure cannot reach the| outlet pressure and replace it|
The machine does not stop when the pressure tank is full| high-pressure
setting pressure| |
The high voltage cannot be taken off, and the power cannot be cut off| Replace
the high voltage switch|
| The computer box is faulty| Measure whether the|
| and the water pump power| computer box has output|
| cannot be turned off| voltage and replace it|
The machine shuts down but the waste water does not stop| The solenoid valve
fails to effectively cut off the water| Observe the waste water and change the
four-sided valve|
Check valve to relieve pressure (waste water flow is small)| Observe the waste
water and replace the check valve|
| High-voltage switch failure| Replace the high-voltage|
| | switch|
The machine repeatedly jumps off after the water
is full
| The system has pressure relief phenomenon| Check the pure water pipe- line
after the check valve|
The pre-filter is blocked| Replace the pre-filter|
RO membrane is blocked| Clean or replace RO membrane|
|
Insufficient pure water| The waste water ratio is too conductive| Replace
waste water ratio|
Insufficient high-pressure pump pressure| Measure the pump outlet pressure|
WARRANTY SERVICE
- The warranty period starts from the date of issuing the invoice.
- Warranty period: The whole machine is guaranteed for two years, and the consumables are not within the scope of the warranty.
- Please keep the warranty card properly. The warranty requires the purchase invoice and warranty card to take effect.
- If there is no invoice, the machine number is altered, the user disassembles and replaces the machine by himself, the operation not in accordance with the instructions and all man-made damage are not covered by the warranty.
- If your machine appears abnormal, please unplug it immediately, turn off the water source and contact with us at www.aicksn.com or email your request to tech@aicksn.com
References
- Water Treatment Equipment Manufacturer, Ro System/Water Filter System/Water Softer Supplier | AICKSN
Read User Manual Online (PDF format)