AICKSN-RO-200 RO 200G Reverse Osmosis Water Systems User Guide
- August 3, 2024
- AICKSN
Table of Contents
- Introduction
- Product functions
- Filter Service Life
- Installation diagram of pure water machine
- Purification flow chart
- Technical parameters
- Accessory Package
- Component description drawing
- Electrical schematic diagram
- Installation instructions
- Set up machine
- Special Note
- TROUBLE SHOOTING
- WARRANTY SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AICKSN-RO-200 RO 200G Reverse Osmosis Water Systems User Guide
Introduction
Thank you for choosing AICKSN Reverse Osmosis Water Systems. You now own a
superb Reverse Osmosis (RO) system that adopts the international advanced
reverse osmosis membrane (RO membrane) as the core, and With multi-stage
pretreatment filtering, the filtering accuracy reaches 0.0001
micron,effectively reducing most contaminants, organic and inorganic compound,
unwanted taste and odor from tap water. It is designed to transform your tap
water into distill water.
The entire water production process is fully automatic.
Product functions
- Reverse osmosis membrane separation system: The combined core of this machine adopts a new household RO membrane separation technology that incorporates the latest scientific and technological achievements, which can efficiently remove harmful substances, retain water molecules and dissolve cyanide, and te effluent quality is better .
- Low noise: The imported original parts of this machine have low chatter noise, small spreading, long service life and reliable operation quality.
- With high pressure flushing reverse osmosis membrane kinetic energy (automatic flushing type and microcomputer control series, with automatic strong washing function), which can effectively extend the life of RO glue.
- Automatic control of the water production process (the raw water and the molten iron stop, and the water bucket is full).
Filter Service Life
- 1st Stage PPF filter : Recommend changing every 3~6 months.
- 2nd Stage Carbon block filter: Recommend changing every 9~12 months.
- 3rd Stage Hollow fiber UF Membrane: Recommend changing every 24~27 months.
- 4th Stage RO Membrane : Recommend changing every 24~36 months.
- 5TH Inline carbon filter: Recommend changing every 18~24 months.
Electrical schematic diagram
Installation diagram of pure water machine
Put the module shell holder into the module housing cover , then urn the membrane cove anticlockwise , tear off the bag of reverse osmosis membrane and put the membrane into the module housing
(Counter clockwise Clockwise tight)
Put the module shell holder into the module housing cover , then urn the
membrane cove anticlockwise , tear off the bag of reverse osmosis membrane and
put the membrane into the module housing
- First open the membrane bag and open the membrane cover.
- Insert the O-ring end of the reverse osmosis membrane into the membrane shell and push the membrane to the bottom
- Finally screw on the diaphragm cover
Note: the reverse osmosis membrane must be inserted to the bottom
Purification flow chart
- PP cotton filter
- ACF carbon filter
- Ultrafiltration
- Solenoid valve
- Booster pump
- RO
- Post carbon filter
Technical parameters
Input power supply : 110-220 V / 50-60 Hz
Output power supply : 24 V / 3A
Inlet water pressure : 0 . 15-0 . 4mpa
Inlet water temperature : 5-45 degrees
Inlet water quality : s 1000ppm
Inlet pipe diameter : 1 / 4″
Outlet pipe diameter : 1 / 4″
Waste water pipe diameter : 1 / 4 ”
Water production : 1.1L / min
Flushing method : manual flushing [ once every 30-60 days )
Pure wastewater ratio : can be adjusted manually
Accessory Package
- 3 water inlet PE pipe 1 / 4 ” : 2m
- 2 branch PE pipe 1 / 4 ” : 3M
- Inlet three-way ball valve : 1 set
- Stainless steel tap : 1
- Gooseneck hanging piece : 1
- Reverse osmosis membrane : 1
- Module shell wrench : 1
- Transformer : 1
- 2 points direct : 1
- Tank: 1
Component description drawing
Pressure gauge Function Fault diagnos is When the machine works normally , the pressure is between 0.55 Mpa and 0.7 Mpa , and the reverse osmosis membrane is blocked or the waste water ratio is not coordinated. which is less than 0.5 mpa-0 Mpa
- Replace the pump when the pump loses pressure
- Replace the filter element if the first two filter elements are blocked
- Whether the inlet water pressure is insufficient , the water inlet requirement is 0 .15mpa-0 .4mpa High quality silicone foot pad to prevent wet corrosion of support frame
Level 4 : Reverse osmosis membrane
The filtration precision reaches 0.0001 um it can intercept heavy metals ,
soluble solids , bacteria , viruses , heat sources and otherharmful impurities
in water . Only water molecules and dissolvedoxygen are retained , and the
effective interception rate is more than 95%.
Level 1 : PPF polypropylene fiber filter element
Function : it is made of food grade polypropylene fiber material
byspecial process , which can intercept sediment , rust , suspended solids .
colloid . etc in water.
Level 2 : sintered activated carbon
Function : Made from sintered coconut shell activated carbon ,
itcahleffectively adsorb residual chlorine , organic matter , peculiarsmell ,
macromolecular impurities and decolorize in water.
Level 3 : ultrafiltration membrane
The filtration precision is 0.01 um . it can intercept bacteria,viruses , heat
sources and other harmful impurities in water Water molecules and dissolved
oxygen are retained , and the effective interception rate is more than 95%
Electrical schematic diagram
Installation instructions
- Close the main water inlet valve of the tap water and open the parts package of this pure water machine. Wrap the external thread of the 1/4″ water inlet ball valve on the raw material tape and connect it to the side hole of the water inlet tee, then wrap the external thread of the water inlet tee on the raw material tape and connect to the reserved 1/2″ The tap water pipe joint.
- Because this machine uses membrane separation technology, waste water will be discharged during the water production process. A small hole (6mm) is reserved in the sewer to facilitate the insertion of the drainage pipe. After installation, it needs to be sealed with silicone to prevent water leakage
- Tap a small 12mm hole in a suitable place on the water bucket, and then install the goose neck faucet (matched with the pressure storage bucket). The goose neck faucet can also be fixed on the wall with a plastic hanger.
- Check the host is installed on the table or under the sink to determine how many holes to drill for the water pipe (the following is for reference only, and the actual installation should depend on the actual situation).
(1)The matching model of RO host and pressure storage bucket: If the host and pressure storage bucket are installed under the cabinet, there is no need to drill another; if the host is installed on the table and the pressure bucket is installed under the cabinet, drill 4 6mm holes are connected to the water inlet pipe, the pressure barrel water pipe, the pure water pipe and the drain pipe respectively.
(2)RO main pipe and pipeline machine supporting models. Both the main machine and pipeline machine are installed on the platform. At this time,3 6mm holes should be drilled to pass through the inlet pipe, drain pipe and overflow pipe (line machine).
(3)under the sink. At this time, 4 6mm holes should be drilled to connect the water inlet, the pressure bucket water pipe, the drain pipe, and the drain pipe.
(4)After the pipe is connected to the drill hole, silica gel is required to prevent water seepage.
(5)Connect the pressure tank to the pressure tank ball valve, and connect the 1/4″ water pipe joint.
(6)Put a pipe plug on the 1/4″ PE water pipe nozzle and connect the water pipe.
Set up machine
Set up machine
After confirming that the waterway connection is correct, you must also
confirm:
- Whether the power socket has electricity
- Is there a water supply from Then enter the debugging of this machine, the method is as follows:
- Open the main tap water inlet valve, and open the water inlet ball valve (the valve handle is in a line with the valve body), close the pressure bucket ball valve, and open the goose neck faucet. 2. Insert the power trace head into the power socket.
At this time, the high-pressure pump starts. After a while, it starts to drain from the waste water outlet, and enters the state of fresh water after 1.5 minutes. Also, after waiting for a period of time, there is water flowing from the goose neck faucet.
After 10-20 minutes, open the pressure barrel ball and pour water into the pressure barrel. When using this product for the first time, the pure water that enters the pressure storage tank must be discharged twice before it can be used after it is full.
Note:
(1)When using this water purifier for the first time, there may be a small amount of black water when you turn on the goose neck faucet to drain the water. Please continue to rinse.
(2)The TDS test data may be slightly higher when the water purifier is used for the first time, please continue to rinse.
Special Note
Please read the “Instruction Manual” repeatedly before using this water purifier, and strictly follow the requirements in the manual for installation, use and maintenance. If the user fails to install, use and maintain as required and cause an accident, our company will not bear any responsibility for this.
- The main connecting parts of this machine are plastic products. The user must always observe its integrity during use to ensure safe use. When the user goes out for a long time or does not use the machine, be sure to close the water inlet valve, disconnect the power supply, and discharge all the pure water from the pressure tank.
- The machine should not be placed in an excessively humid place, otherwise it will cause spots on some metal parts of the machine.
- The recommended replacement cycle of various filter elements in this machine is calculated by referring to the average index of tap water in the scope of use that meets the national standard. If the water quality at the user’s actual use differs greatly from the average index, there will be a significant difference between the actual use state and the estimated period (such as premature clogging of the filter element, premature failure, etc.). At this time, filter elements replace should be based on the actual use state.
- The estimation of the life cycle is based on ordinary household water. Users with a large water consumption such as units will quickly reach the total water intake. Please replace the filter as soon as possible.
TROUBLE SHOOTING
NOTE: Turn off the system before servicing.
PROBLEM | POSSILE CAUSE | SULUTION |
---|---|---|
The machine does not start | The power is not turned on | Check the power supply |
or the power plug
Low pressure of raw water or water cut off| Check raw water pressure
The low-voltage switch fails and cannot be connected to the power supply|
Measure the resistance after connecting the raw watered replace it
The high voltage switch cannot be reset| Measure its resistance after
releasing the pressure and replace it
Transformer burns out| Measure its output voltage and replace it
The computer box has no output voltage| Measure its output voltage and replace
it
The high-pressure pump works normally but cannotproduce water| Pressure loss
of high-pressure pump| Measure the outlet pressure of the pump and replace it
---|---|---
The inlet solenoid valve (four-sided valve) is faulty and cannot enter water
(there is no pure water or wastewater)| Replace the inlet solenoid valve
(four-sided valve)
The pre-filter is blocked| Observe the pure water and waste water, and replace
the pre-filter
Check valve is blocked (waste water but no pure water)| replace check valve
The automatic flushing solenoid valve fails and cannot be effectively closed
(it is always in flushing state, and the waste water is large)| Observe the
wastewater flow rate and replace the auto- mastic flushing solenoid valve
(refer to microcomputer type)
The computer box is faulty and the flushing solenoid valve cannot be closed
(always in the flushing state)| Measure the input voltage of the flushing
solenoid valve. Replace the computer box (refer to the microcomputer box)
RO membrane is blocked| Clean or replace Remembrance
WARRANTY SERVICE
- The warranty period starts from the date of issuing the invoice.
- Warranty period: The whole machine is guaranteed for two years, and the consumables are not within the scope of the warranty.
- Please keep the warranty card properly. The warranty requires the purchase invoice and warranty card to take effect.
- If there is no invoice, the machine number is altered, the user disassembles and replaces the machine by himself, the operation not in accordance with the instructions and all man-made damage are not covered by the warranty.
- If your machine appears abnormal, please unplug it immediately, turn off the water source and contact with us at www.aicksn.com or email your request to tech@aicksn.com
U.S. AICKSN Technology Co.,Ltd.
Address: 250 w clifton st tampa,FL.33614 Aicksn (Fujian) Environmental
Protection Technology Co., Ltd
Tel: 0086 0592-5776975 0086 0592-5569172
Email:www.aicksn.com
National Unified Hotline:
400-615-5998
References
- Water Treatment Equipment Manufacturer, Ro System/Water Filter System/Water Softer Supplier | AICKSN
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>