AICKSN Central Reverse Osmosis Water Filtration Systems Installation Guide

August 3, 2024
AICKSN

AICKSN Central Reverse Osmosis Water Filtration Systems

Product Information

Product Specifications

  • 800G: Rated voltage: 110-220V 50-60Hz, Output voltage: 24V / 5A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/2 3/4 to 3/8, Water outlet pipe size: 3/4 to 1/2 3/4 to 3/8
  • 1200G: Rated voltage: 110-220V 50-60Hz, Output voltage: 24V / 5A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/2 3/4 to 3/8, Water outlet pipe size: 3/4 to 1/2 3/4 to 3/8
  • 2000G: Rated voltage: 110-220V 50-60Hz, Output voltage: 36V / 7A, Water inlet pressure: 0.15-0.4Mpa, Water inlet requirement: Municipal water, Water inlet temperature: 5-45, Water inlet pipe size: 3/4 to 1/2 3/4 to 3/8, Water outlet pipe size: 3/4 to 1/2 3/4 to 3/8

Product Usage Instructions

Installation Instructions

  1. Read the Instruction Manual thoroughly before starting the installation process.
  2. Follow the provided installation diagram for the proper placement of components.
  3. Connect the necessary pipes and valves according to the specified sizes and instructions.
  4. Ensure all connections are secure and leak-free before turning on the system.

Special Note
Please read the Instruction Manual repeatedly before using this water purifier, and strictly follow the requirements in the manual for installation, use, and maintenance. If the user fails to install, use, and maintain as required and causes an accident, our company will not bear any responsibility for this.

FAQ

  • Q: How often should I change the filters in the system?
    A: The ACF filters should be changed every 6-12 months, and the RO membranes should be replaced every 2-3 years as recommended in the manual.

  • Q: What is the warranty period for this product?
    A: Please refer to the Warranty Service section in the manual for details on the warranty coverage and duration provided by the manufacturer.

Introduction

Thank you for choosing AICKSN Reverse Osmosis Water Systems. You now own a superb Reverse Osmosis (RO) system that adopts the international advanced reverse osmosis membrane (RO membrane) as the core, With multi-stage pretreatment filtering, the filtering accuracy reaches 0.0001 micron, effectively reducing most contaminants, organic and inorganic compounds, unwanted taste and odor from tap water. It is designed to transform your tap water into distilled water. The entire water production process is fully automatic.

System includes

800G 1200G 2000G
RO host 1pc RO host 1pc RO host 1pc
RO membrane 2pc RO membrane 2pc RO membrane 2pc
ACF filter 2pc ACF filter 2pc ACF filter 2pc
Parts kit 1pc Parts kit 1pc Parts kit 1pc
user manual 1 user manual 1 user manual 1
Stainless steel faucet 1pc Stainless steel faucet 1pc Stainless steel faucet

1pc
3/8” PE pipe 4m| 3/8” PE pipe 4m| 3/8” PE pipe 4m
1/4” pe pipe 2m| 1/4” pe pipe 2m| 1/4” pe pipe 2m
| Straight valve 1pc| Straight valve 1pc
Adaptor 1pc| Adaptor 1pc| Adaptor 1pc
Hose connector (3/4” to 3/8”) 2pc| Hose connector (3/4” to 3/8”) 2pc| Hose connector (3/4” to 3/8”) 2pc
Three-way ball valve 1pc| Three-way ball valve 1pc| Three-way ball valve 1pc
L-shaped elbow 2pc| L-shaped elbow 2pc| L-shaped elbow 2pc
Red buckle 2pc| Red buckle 2pc| Red buckle 2pc
| 3/4” straight connector 1pc| 3/4” straight connector 1pc
Silicone oil 1 pack| Silicone oil 1 pack| Silicone oil 1 pack

Product specification

| 800G| 1200G| 2000G
---|---|---|---
Rated voltage| 110-220V 50-60Hz| 110-220V 50-60Hz| 110-220V 50-60Hz
Output voltage| 24V / 5A| 24V / 5A| 36V / 7A
Water inlet pressure| 0.15-0.4Mpa| 0.15-0.4Mpa| 0.15-0.4Mpa
Water inlet requirement| Municipal water| Municipal water| Municipal water
Water inlet temperature| 5-45℃| 5-45℃| 5-45℃
Water inlet pipe size| 3/4” to 1/2”

3/4” to 3/8”

| 3/4” to 1/2”

3/4” to 3/8”

| 3/4” to 1/2”

3/4” to 3/8”

Water outlet pipe size| 3/4” to 1/2”

3/4” to 3/8”

| 3/4” to 1/2”

3/4” to 3/8”

| 3/4” to 1/2”

3/4” to 3/8”

Wastewater pipe size| 1/4”| 1/4”| 1/4”
Rated flow≥| 1.7L/M| 2.2L/M| 4.2L/M
Flushing method| Automatic flushing| Automatic flushing| Automatic flushing
Wastewater ratio| Manual adjustable| Manual adjustable| Manual adjustable

Filter Service Life

  • 1st Stage ACF filter: Recommend changing every 6~12 months.
  • 2nd Stage ACF filter: Recommend changing every 6~12 months.
  • 3rd Stage RO Membrane: Recommend changing every 2~3 years.
  • 4th Stage RO Membrane: Recommend changing every 2~3 years.

Installation instruction

  1. Preparations before installation
    • Confirm the installation position of the water purifier, the power supply, and the concentrated underwater water pipe [The installation should depend on the time situation]
    • Confirm that all accessories required for installation are complete. [Refer to the packing list for details] Close the water inlet valve before installation.
  2. Installation steps:
  3. Connect the filter to the corresponding connector of the host;
  4. Connect two RO membrane wastewater pipes in parallel to the three-way inlet; 2.3 Connect the 1/4” PE pipe to the host wastewater outlet, and connect the other end of the 1/4” PE pipe to the sewer pipe.

Machine debugging:
After confirming that the water connection is correct, open the water inlet three-way ball valve [confirm whether there is a tap water supply], and plug it into the power supply [confirm whether the socket has electricity], at this time the high-pressure pump starts, the wastewater outlet starts to drain, after entering the water production state, there will be a small amount of white protective liquid when the water purifier tap is turned on for the first time, and the water will be kept for 3-10 minutes until there is no white protective liquid. The TDS data will be slightly higher when the pure water machine is used for the first time, and it is necessary to continue to discharge the water to make the machine produce a water flow of about 50-100 liters.

Purification flow chart

AICKSN-Central-Reverse-Osmosis-Water-Filtration-Systems-Fig-
\(2\)

Component description drawing

AICKSN-Central-Reverse-Osmosis-Water-Filtration-Systems-Fig-
\(3\) AICKSN-Central-Reverse-Osmosis-
Water-Filtration-Systems-Fig- \(5\)

Special Note

Please read the “Instruction Manual” repeatedly before using this water purifier, and strictly follow the requirements in the manual for installation, use, and maintenance. If the user fails to install, use, and maintain as required and causes an accident, our company will not bear any responsibility for this.

  1. The main connecting parts of this machine are plastic products. The user must always observe its integrity during use to ensure safe use. When the user goes out for a long time or does not use the machine, be sure to close the water inlet valve, disconnect the power supply, and discharge all the pure water from the pressure tank.
  2. The machine should not be placed in an excessively humid place, otherwise it will cause spots on some metal parts of the machine.
  3. The recommended replacement cycle of various filter elements in this machine is calculated by referring to the average index of tap water in the scope of use that meets the national standard. If the water quality at the user’s actual use differs greatly from the average index, there will be a significant difference between the actual use state and the estimated period (such as premature clogging of the filter element, premature failure, etc.). At this time, filter element replacement should be based on the actual use state.
  4. The estimation of the life cycle is based on ordinary household water. Users with a large water consumption such as units will quickly reach the total water intake. Please replace the filter as soon as possible.

TROUBLESHOOTING

NOTE: Turn off the system before servicing.

AICKSN-Central-Reverse-Osmosis-Water-Filtration-Systems-Fig-
\(6\) AICKSN-Central-Reverse-Osmosis-
Water-Filtration-Systems-Fig- \(7\)

WARRANTY SERVICE

  1. The warranty period starts from the date of issuing the invoice.
  2. Warranty period: The whole machine is guaranteed for two years, and the consumables are not within the scope of the warranty.
  3. Please keep the warranty card properly. The warranty requires the purchase invoice and warranty card to take effect.
  4. If there is no invoice, the machine number is altered, the user disassembles and replaces the machine by himself, the operation is not per the instruc-tions and all man-made damage is not covered by the warranty.
  5. If your machine appears abnormal, please unplug it immediately, turn off the water source, and contact us at www.aicksn.com or email your request to tech@aicksn.com.

U.S. AICKSN Technology Co., Ltd.

  • Address: 250 W. Clifton st Tampa, FL.33614 Fujian Aicksn Environmental Technology Co., Ltd.
  • Tel: 0086 0592-5776975, 0086 0592-5569172
  • Email: www.aicksn.com
  • National Unified Hotline: 400-615-5998

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals