DELLA 048-OPAC-9B Portable Air Conditioner
Product Usage Instructions
Parts Details
The product includes various parts such as the control panel, air outlet,
temperature display, carrying handle, air filter, drain outlets, power plugs,
etc. Refer to the manual for detailed information on each part.
Installation Guide
-
Picking an Installation Location
Choose a suitable location for installation away from flames, gas appliances, or electric heaters. Ensure proper ventilation around the unit. -
Connecting the Exhaust Hose
Connect the exhaust hose to the designated outlet on the unit securely to ensure proper air circulation. -
Extending the Window Slider Kit
Adjust the window slider kit to fit your window size properly to prevent air leaks. -
Attaching the Exhaust Hose to the Unit
Attach the exhaust hose to the unit following the instructions provided in the manual for a secure connection. -
Connecting the Exhaust Hose to the Window
Depending on your window type (vertical or horizontal), use the foam seal provided to attach the exhaust hose securely to the window for efficient operation. -
Control Panel
The control panel features various buttons with functions like Power ON/OFF, Mode selection, Sleep mode activation, temperature adjustment, fan speed control, timer settings, and oscillation control. Refer to the manual for detailed instructions on each function. -
Remote Control
The remote control allows you to operate the air conditioner from a distance. It includes buttons for Power, Mode selection, Fan speed control, Swing mode, temperature adjustment, timer settings, and Sleep mode. Follow the manual for battery replacement instructions. -
Operation Instructions
To power ON/OFF the air conditioner, use either the Power button on the unit or the Power button on the remote control.
Frequently Asked Questions (FAQ)
-
Q: How do I clean the air filter?
A: To clean the air filter, carefully remove it from the unit and wash it with mild soap and water. Allow it to dry completely before reattaching it. -
Q: What should I do if the unit displays an error code?
A: In case of an error code, refer to the user manual for troubleshooting steps. If the issue persists, contact customer support for assistance.
This manual contains the information you need to install and use your product. Keep this manual for future reference.
Warning and Safety
Read this guide before installing and using this appliance. Failure to follow the safety instructions may result in property damage, serious injury, or death.
-
DANGER
Indicates an imminently hazardous situation that, if not avoided, will result in death, serious injury, or serious property damage. -
WARNING
Indicates a potentially hazardous situation that, if not avoided, will result in death, serious injury, or serious property damage. -
CAUTION
Indicates a potentially hazardous situation that, if not avoided, will result in minor to moderate injury. It may also be used to indicate unsafe practices.
DANGER
- In the case of the appliance emitting smoke or a burning smell, shut down the appliance and disconnect from the power supply immediately.
- This appliance uses R32 refrigerant. Handle the air conditioner with care and check if there is any refrigerant leakage. In the case of refrigerant leakage, shut down the appliance and disconnect from the power supply. Contact a qualified technician for inspection. Refrigerant can be toxic and flammable. Rapid evaporation of refrigerant may cause frostbite, cardiac arrhythmia, and/or skin irritation.
WARNING
- This appliance must be plugged directly into a wall power socket. Do not connect this appliance to a power strip, extension cord, surge protector, timers, or direct breaker.
- Ensure the voltage and current rating of the power supply corresponds to that on the product specification.
- Make sure the appliance is connected to a properly grounded power outlet only.
- Do not use the appliance with a damaged cord or plug, or after the appliance malfunctions, has been dropped, or dais maged in any manner.
- This appliance is designed to be used indoors only. Do not use this appliance outdoors or expose it to outdoor elements such as rain, snow, sunlight, wind, or extreme temperatures.
- Do not place or use the appliance in the bathroom, laundry area, or places that might come into contact with water.
- Do not use this appliance near flammable substances such as alcohol, gasoline, paint, etc. Or pressurized containers such as spray cans.
- Repairs should be carried out by a professional or qualified technician only. Incorrect repair could expose the user to potential electric shock or other kinds of hazards.
- Do not place the appliance in contact with water. The electrical insulation could be damaged and thus cause electric shock.
- Do not bend, tug, pull, or compress the power cord to prevent damaging the power cord.
CAUTION
- Do not run the power cord under the carpet or cover the cord with throw rugs, runners, or similar covering. Arrange the cord away from high high-traffic area to prevent tripping over it.
- Only use this appliance as described in this manual.
- Do not obstruct the air inlet or outlet.
- Do not use abrasive solvents to clean this appliance.
- Proper adult supervision is required when using this appliance when there are children, persons with reduced physical, sensory, or mental capabilities, or pets present.
- Do not leave the appliance operating unattended.
- Do not touch any moving parts when the air conditioner is in operation.
Product Specification
Model | 048-OPAC-9B |
---|---|
Rated Voltage | 115 V |
Frequency | 60 Hz |
Cooling Capacity | 14000 BTU / h |
Recommended Room Size | Up to 550 sq. ft |
Dehumidification | 68 Pint / Day |
Noise Level | 54 – 56 dB |
Refrigerant Type, Charge | R32, 13.76 oz |
Dimension | 17.3″ x 13.2″x 26.2″ |
Net Weight | 62.8 lb |
Operation Temperature | 61°F – 90°F (Cooling Mode) 41°F – 81°F (Heating Mode) |
Parts Details
Installation Guide
Picking an installation location
- The air conditioner must be placed on a flat ground.
- Keep the air conditioner at least 50 cm or 19.7″ away from any wall or obstacles.
- Do not place the air conditioner in the laundry room or near any open ignition sources such as open flames, gas appliances, or electric heaters.
Connecting the exhaust hose
Connect the exhaust hose to the hose connector and window kit adapter.
Extending the window slider kit
- Adjust the length of the window slider kit according to your window, and then secure the position with the provided screws.
Attaching the exhaust hose to the unit
- Slide the hose connector to the air exhaust on the unit, and attach the window kit adapter to the window slider kit.
Connecting the exhaust hose to the window
- Attach foam seal to the window sash and the window frame.
- Place the window slider kit between the window sash and window frame.
- The exhaust duct should be kept to a minimum length and as straight as possible.
- Stretching or bending the duct excessively will decrease cooling efficiency.
Control Panel
Remote Control
Icon
| Button Name|
Function
---|---|---
POWER| Power Button| Power ON / OFF the air conditioner
MODE| Mode Button| Change the operation mode setting
SPEED| Speed Button| Control the fan speed
SWING| Swing Button| Enable the air outlet to oscillate
– TEMP/HRS +| Increase/Decrease Button| Adjust temperature/timer setting
TIMER| Timer Button| Enable shut down/turn on timer
SLEEP| Sleep Button| Enable sleep mode
°C/°F| Unit Button| Changing display unit between °C and °F
Changing the Remote Control Battery
- Remove the back cover and insert 2 new AAA 1.5v batteries. (not included)
- Re-install the back cover to the remote control.
WARNING
- Do not use rechargeable batteries.
- Replace the old batteries with new ones of the same type.
- Do not dispose battieries as unsorted municipal waste.
Operation Instructions
Power ON/OFF
- Press on the control panel or press POWER on the remote control to turn on the unit.
- Press on the control panel or press POWER on the remote control again to turn off the unit.
Cool Mode
- Press on the control panel or MODE on the remote control to select cool mode.
- the indicator will light up on the control panel.
- Press on the control panel or – + on the remote control to adjust the temperature setting.
- Temperature can be set from 16°C – 32°C / 61°F – 90°F.
- Press on the control panel or SPEED on the remote control to adjust fan speed.
Dry Mode
- Press on the control panel or MODE on the remote control to select dry mode.
- the indicator will light up on the control panel.
Fan Mode
- Press on the control panel or SPEED on the remote control to select fan mode.
- the indicator will light up on the control panel.
- Press on the control panel or SPEED on the remote control to adjust fan speed.
Heat Mode
- Press on the OL panel or on the remote control to select cool mode.
- the indicator will light up on the control panel.
- Press on the control panel or – + on the remote control to adjust the temperature setting. Temperature can be set from 61°F – 90°F.
- Press on the OL panel or SPEED on the remote control to adjust fan speed.
Oscillation Function
- Press on the OL panel or SWING on the remote control to enable vent oscillation.
- The vents on the air conditioner will oscillate side to side.
- Press on the OL panel or SWING on the remote control again to disable the vent oscillation.
Turn ON Timer
- Make sure the air conditioner is OFF.
- Press on the control panel or TIMER on the remote control to begin setting turn on timer.
- Press on the control panel or – + on the remote control to set the desired time.
- Leave the setting for 5 seconds, the air conditioner will start the timer automatically.
- Set the timer to 00 or manually turn ON the unit to cancel the timer setting.
Shut OFF Timer
- Make sure the air conditioner is ON.
- Press on the control panel or TIMER on the remote control to begin setting the shut-off timer.
- Press on the control panel or – + on the remote control to set the desired time.
- Leave the setting for 5 seconds, the air conditioner will start the timer automatically.
- Set the timer to 00 or manually turn OFF the unit to cancel the timer setting.
Changing Temperature Unit
- Press °C/°Fon the remote control to change the temperature unit between degree Celsius and degree Fahrenheit.
Sleep Mode
- Press on the control panel or SLEEP the remote control to enable sleep mode.
- In cool mode, the air conditioner will increase temperature by 2°F after 1 hour, and then another 2°F after the 2nd hour. Then the air conditioner will keep the temperature constant for 10 hours.
Automatic Defrost
At low room temperature, frost may build up at the evaporator during
operation. The unit will automatically start defrosting and the power
indicator will blink. The defrost control sequence is as follows:
- When the unit operates in cooling or drying mode, and the ambient temperature sensor detects the evaporator coil temperature is below 30°F, the compressor will stop operating for 10 minutes or with the coil temperature raised to 44°F. After that, the unit will restart the cool mode operation.
- When the unit operates in dry mode, once the coil temperature sensor detects the temperature of the evaporator is below 104°F and the differential temperature between coil temperature and room temperature is below 66°F after the compressor operation for 20 minutes, the unit starts defrosting for 5 minutes and the power indicator blinks.
Overload Protection
In the event of power loss, there is a 3-minute delay to protect the
compressor before it restarts.
Grounding
- This product must be properly grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
- For additional safety, the power cord features an integrated circuit breaker. Test and reset the buttons provided on the plug.
- The circuit breaker should be tested periodically by pressing the TEST button. If it does not cause the circuit breaker to trip or if the RESET button will not stay engaged, unplug the unit immediately and contact your service technician.
WARNING
- Improper connection can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded.
- Do not modify the plug provided with the product.
Water Drainage
-
When the internal water tank is full the digital display will show an “FL” error code.
-
Carefully move the air conditioner to a drain location, then remove the bottom drain plug and drain the water.
-
After draining, re-install the drain plug and restart the air conditioner.
-
For continued drainage during dry mode, remove the upper drain plug and insert a drain hose into the outlet.
-
Place the other end of the hose to a drain area.
Attention
- Do not submerge the end of the hose into the water to prevent an airlock.
Care and Maintenance
CAUTION
- Before cleaning the unit, you must shut down the machine and cut off the power supply.
- Never flush the air conditioner with water.
Clean the Unit
- Clean the heater with a soft dry cloth or a damped cloth with neutral detergent.
NOTE:
- Do not flush the machine with water.
- Do not use volatile liquids such as thinner or alcohol to prevent damaging the unit.
Clean the Air Filter
- Remove the air filters from the air conditioner.
- Clean the air filters with a vacuum cleaner or with warm water with a mild neutral detergent.
- Make sure the air filters are dry and then re-install them to the air conditioner.
Storage
If you will not be using the unit for an extended period, it is best to clean
and dry out the unit completely.
- Unplug the unit from the power outlet and detadetachaust hose and window sliding kit from the unit.
- Drain the remaining water from the unit.
- Clean and dry the air filter.
- Re-install the cleaned air filter at its position.
- Store the unit in a dry indoor location. The unit must be kept in an upright position.
Attention
The evaporator of the unit must be dried out before storage to prevent
molds by leaving the machine in a dry open area or turning on the machine with
low-speed fan mode.
Troubleshooting
Problem
|
Possible Causes
---|---
The appliance is nonoperational
| Power failure/plug pulled out
Power breaker tripped
Full water tank
Outside of operation temperature
The appliance is working at a reduced capacity| Obstruction on the vent
Dirty air filter
Room is too big / window and/or door are open
The exhaust hose is not properly attached
Water Leak| Full water tank
Noise or Vibration| The appliance is placed on uneven ground
Error Code
Code
|
Meaning
---|---
00/E0| Communication fault between main PCB and display PCB
E1| Ambient temperature sensor failure
E2| Coil temperature sensor failure
Ft| Full water tank
Disposal Guideline
This appliance contains refrigerant and other potentially hazardous materials. When disposing of the appliance, follow all federal, state, and local regulations. DO NOT dispose of this product as normal household waste or unsorted municipal waste.
When disposing of this appliance, you have the following options:
- Dispose of this appliance at a designated municipal electronic waste collection facility.
- When buying a new appliance, the retailer will take the old appliance.
- The manufacturer may take back the old appliance.
- Sell the appliance to a certified scrap metal dealer.
FCC STATEMENT
- Model: 048-OPAC-9B
- ID: 2ANDL-WBR3
FCC Caution
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, under part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates users and can radiate radio frequency
energy and, if not installed and used by the instructions, may cause harmful
interference to radio communications, However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to a radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
IC Warning
This device complies with Industry Canada’s license-exempt RSSs. Operation is
subject to the following two conditions:
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
www.dellahome.com. manufacturer@dellahome.com 800-863-4143 6:00a.m. – 4:00 p.m. PST Monday – Friday ©Della All rights reserved.
- Under copyright law, this document may not be printed, translated, reproduced, or distributed, in whole or in part without written permission from DELLA.
- Every effort has been made to ensure that the information in this document is accurate, DELLA is not responsible for printing or clerical errors.
All trademarks, logos, and brand names are the property of their respective companies. Mention of third-party products or service names is for identification and informational purposes only. Use of these names, brands, and trademarks does not imply endorsement. DELLA assumes no responsibility for the performance or use of these products.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>