DELLA 48-OPAC Portable Air Conditioner User Manual
- June 14, 2024
- DELLA
Table of Contents
PORTABLE AIR CONDITIONER Model# 048-OPAC-5H/6H
User Manual
CAUTION! WARNING: Read all instructions before use this device.
NOTICE:
If your package is missing parts or you are having issues with assembly,
please call Della directly at
800-863-4143.
The Della customer service team will address any questions or cancems you may
have.
Have this manual open and ready for reference.
Product appearance and color may vary from pictures.
Keep the manual properly for future reference.
CUSTOMER SERVICE:
800-863-4143
DOAM – 6:00PM PST (Monday – Friday)
Email: manufacturer@dellausa.com
www.dellahome.com
BEFORE YOU BEGIN
1.1 PRODUCT DESCRIPTION
Our powerful portable air conditioners are great cooling solutions for single
rooms, creating a comfortable atmosphere in your space. It also has
ventilation and dehumidifying functions for circulating air and removal of
moisture. They’re self-contained systems that do not require any permanent
installation allowing you to move to the space in which it is most needed.
They’re commonly used in kitchens, temporary-resided, computer rooms, garages,
and many other places where installation of Air-conditioner Outdoor unites is
limited.
The environmentally friendly R32 is used as the refrigerant. R32 has no
damaging influence on the ozone layer (ODP), a negligible greenhouse effect
(GWP) and is available worldwide. Because of its efficient energy properties,
R32 is highly suitable as a coolant for this application. Special precautions
must be taken into consideration due to the coolant’s high flammability.
1.2 SYMBOLS FROM THE UNIT AND USER MANUAL
warning| This unit uses a flammable refrigerant.
If refrigerant leaks and comes in contact with fire or heating part, it will
create harmful gas and there is risk of fire.
---|---
| Read the USER MANUAL carefully before operation.
****| Further information is available in the USER MANUAL, SERVICE MANUAL,
and the like.
| Service personnel are required to carefully read the USER MANUAL and
SERVICE MANUAL before operation.
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
-
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
-
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. -
The unit is designed only for use with R32 gas as the designated refrigerant.
-
The refrigerant loop is sealed. Only a qualified technician should attempt to service it!
-
Do not discharge the refrigerant into the atmosphere.
-
R32 gas is flammable and heavier than air.
-
It collects first in low areas but can be circulated by the fans.
-
If R32 gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
-
The R32 gas used in the unit has no odor.
-
The lack of smell does not indicate a lack of escaped gas.
-
If a leak is detected, immediately evacuate all persons from the area, ventilate the room and contact the local fire department to advise them that an R32 gas leak has occurred.
-
Do not let any persons back into the room until the qualified service technician has arrived, and that technician advises that it is safe to return to the room.
-
No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.
-
Component parts are designed for R32 gas and are nonflammable and non-sparking. Component parts shall only be replaced with identical repair parts.
FAILURE TO ABIDE BY THESE WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
FOR YOUR SAFETY
Your safety is the most important thing we’re concerned about! Your safety is the most important thing we concerned!
WARNING| Please read this manual carefully and fully understand it
before operating your appliance.
---|---
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons
or property:
- If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be disconnected from its power source during service.
- Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
- Do not operate with wet hands. Prevent water from spilling onto the unit.
- Do not immerse or expose the unit to rain, moisture or any other liquid.
- Do not leave the unit running unattended. Do not tilt or turn over the unit.
- Do not unplug while the unit is operating.
- Do not unplug by pulling on the power cord.
- Do not use an extension cord or an adapter plug.
- Do not put objects on the unit.
- Do not climb or sit on the unit.
- Do not insert fingers or other objects into the air outlet.
- Do not touch the air inlet or the aluminum fins of the unit.
- Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
- Do not clean the appliance with any chemicals.
- Ensure the unit is far away from fire, inflammable, or explosive objects.
- The unit shall be installed in accordance with national wiring regulations.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
- The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Do not piece or burn, even after use.
- Be aware that refrigerants may not contain an odor.
- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 4 m².
- Compliance with national gas regulations shall be observed.
- Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
WARNING| Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry, recognized assessment
specification.
---|---
WARNING| Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.
If you don’t understand something or need help, please contact the dealer
services.
NOTES:
■ The unit shall be installed in accordance with national wiring regulations.
■ Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
■ The appliance shall be stored in a room without continuously operation
sources (for example: open flames, an operating gas appliance, or an operating
electric heater).
■ The appliance shall be stored so as to prevent mechanical damage from
occurring.
■ Do not piece or burn, even after use.
■ Be aware that refrigerants may not contain an odor.
■ Pipework shall be protected from physical damage and shall not be installed
in an unventilated space, if that space is smaller than 4 m².
■ Compliance with national gas regulations shall be observed.
■ Keep any required ventilation openings clear of obstruction.
■ The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
■ Ensure the unit is far away from fire, flammable, or explosive objects.
WARNING: Any person who is involved with working on or breaking into a
refrigerant circuit should hold a currently valid certificate from an
industry- accredited assessment authority, which authorizes their competence
to handle refrigerants safely in accordance with industry standards and
recognized assessment specifications.
WARNING: Servicing shall only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the assistance of
other skilled personne! shall be carried out under the supervision of the
person competent In the use of flammable refrigerants.
If you don’t understand something or need help, please contact the dealer
services.
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing an
appliance with R32.
2.2.1 Checks to the area
Before beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For
repair to the refrigerating system, the following precautions shall be
complied before conducting work on the system.
2.2.2 Work procedure
Work shall be performed under a controlled procedure to minimize the risk of
flammable gas or vapor being present while the work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of the work being carried out. Work in confined spaces shall be
avoided. The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable
material.
2.2.4 Checking for the presence of refrigerant
The area shall be checked with an appropriate refrigerant detector before and
during work, to ensure the technician is aware of potentially flammable
atmospheres. Ensure that the leak detection equipment being used is suitable
for use with flammable refrigerants, i.e., no sparking, adequately sealed, or
intrinsically safe.
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available
on hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging
area.
2.2.6 No ignition sources
No person carrying out work concerning a refrigeration system that involves
exposing any pipe work that contains or has contained flammable refrigerant
shall use any sources of ignition in such a manner that it may lead to the
risk of fire or explosion. All possible ignition sources, including cigarette
smoking, should be kept sufficiently far away from the site of installation,
repair, removal, and disposal, during which flammable refrigerant can be
released into the surrounding space. Prior to work taking place, the area
around the equipment is to be surveyed to make sure that there are no
flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried out.
The ventilation should safely disperse any released refrigerant and preferably
expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times the manufacturer’s
maintenance and service guidelines shall be followed. If in doubt, consult the
manufacturer’s technical department for assistance.
The following checks shall be applied to installations using flammable
refrigerants:
- The charge size is in accordance with the room size within which the refrigerant-containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
- Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
- Refrigeration pipes or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant-containing components, unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance of electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise the safety, then no electrical supply shall be connected to the
circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of the
equipment so all parties are advised.
Initial safety checks shall include:
- those capacitors are discharged: this shall be done in a safe manner to avoid the possibility of sparking;
- that there are no live electrical components and wiring that are exposed while charging, recovering or purging the system;
- that there is continuity of ground bonding.
WARNING!
Install the unit in rooms which exceed 4 m².
Do not install the unit in a place where inflammable gas may leak.
NOTE!
The manufacture may provide other suitable example or may provide additional
information about the refrigerant odor.
PRODUCT OVERVIEW
3.1 PRODUCT DIAGRAM
1 | Control panel |
---|---|
2 | Air outlet with adjustable louver |
3 | Handle |
4 | Air inlet with air filter |
5 | Caster |
6 | Drainage Hole |
7 | Air Exhaust |
Note: The appearance is only for reference. Please see the real product for detailed information.
- FEATURES
✓ High Capacity in a compact size with cooling, dehumidifying, heating, and fan function.
✓ Temperature setting and display
✓ LED Digital display
✓ Electronic control with built-in timer, sleep mode
✓ Self-evaporating system for better efficiency
✓ Auto shut off when tank full
✓ Automatic restart in the event of power outage
✓ Auto defrosting function at low ambient temperatures
✓ Remote control
✓ 2- speed fan
✓ Casters for easy mobility
INSTALLATION
-
UNPACKING
● Unpack the carton and take the appliance and accessories out.
● Check the device after unpacking for any damage or scratches on it.
● Accessories:
■ 1. Exhaust hose
■ 2. Hose connector
■ 3. Window kit adapter
■ 4. Remote control
■ 5. Drainage pipe
■ 6. Window Kit -
Choose your location
• If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up.
• Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation.
• Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
• Never install the unit where it could be subject to: ➢ Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
➢ Direct sunlight
➢ Mechanical vibration or shock
➢ Excessive dust
➢ Lack of ventilation, such as cabinet or bookcase
➢ Uneven surface
WARNING!
Install the unit in rooms which exceed 4 m².
Do not install the unit in a place where inflammable gas may leak.
NOTE!
The manufacture may provide other suitable example or may provide additional information about the refrigerant odor. -
ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can escape the room which comes from the appliance and contains waste heat and moisture.
Do not replace or extend the exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low back pressure.
Step 1: Connect the hose connector to one end of the exhaust hose.
Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
Step 3: Extend the adjustable window kit the length of your window.
Connect the exhaust hose to the window kit.
Step 4: Close your window to secure the kit in place. It needs to hold the
windows kit firmly in place, secure the window kit with duct tape if required.
It is recommended that the gap between the adapter and the sides of the window
should be sealed off for maximum efficiency. Step 5: Attach the hose connector
to the exhaust air outlet of unit. Step 6: Adjust the length of the flexible
exhaust , to make sure the distance between the unit and the window will be
more than 70cm, and the height from the exhaust hose to the floor will be more
than 90cm. And avoid bends in the hose. Then place AC near an electrical
outlet. Step 7: Adjust the louver at the air outlet, and
then switch on the unit.
OPERATION
- CONTROL PANEL AND DISPLAY
1 | POWER | Press to switch the machine on or off. |
---|---|---|
2 | MODE | Press to switch the operation mode among Cool, dry, fan and heat. |
3 | SPEED | Press to switch the fan speed between HIGH and LOW |
4 | TIMER/WIFI | Sets a time for the unit to automatically start or stop. |
Long press this button to start the network
configuration or disconnect the WIFI.
5| LOCK| Long press to turn on/off the child lock function
6| SLEEP| Press to turn on/off sleep mode.
7| KNOB| Turn left and right to adjust the temperature (61℉−90℉) or timer
setting.
Information on the App “DELLA+”
The “DELLA+” app is available for android and iOS.
Scan the corresponding QR code to get directly to the download.
https://a.smart321.com/dellahomeandroid
Information on How to Use the App
This appliance allows you to operate the appliance via your home network. A
prerequisite is a permanent WIFI connection to your router and the free app
“DELLA+”.
- Install the “DELLA+” app. Create a user account.
- Activate the WIFI function in the settings of your appliance.
- Place the appliance at a distance of about 5 meters from your router.
- Long press the “timer” button to start the network configuration, and when the WIFI indicator flashes, you can connect the WIFI.
After 3 minutes, the status will be canceled if there is no network
configuration, and the indicator light is off. If you need to reconnect the
WIFI, long press the “timer” button for 5 Second to start the network
configuration, and the WIFI indicator flashes again.
WIFI Connected
-
Method 1
Connected via Bluetooth
Open the Bluetooth of your mobile phone or other devices.
When the WIFI indicator flashes, open the “DELLA+” APP, and the unit will be connected via Bluetooth automatically. -
Method 2
When the WIFI indicator flashes, select “Add Device”- “Large Home Appliances”-“Portable Air Conditioner”, and follow the instructions on the display.
Check the status of the WIFI indicator and choose the correct status.
If the WIFI indicator flashes rapidly, it can be connected directly.
If the WIFI indicator flashes slowly, press “Go to Connect” to connect the WIFI named “SmartLife-XXXX”, then back to the APP, the WIFI will connect ok.
Remarks:
Once the appliance has been successfully connected, the WIFI lamp lights up.
Now you can operate the appliance using the app.
Press and hold the Timer button for about 5 seconds, the appliance will
disconnect, and the WIFI lamp lights turn off.
5.2 REMOTE CONTROL 5.3 SETTINGS
5.3.1 Start-up and Shutdown
Press POWER to turn on the unit.
Press MODE button to select the desired operation mode.
Press POWER again to turn off the power.
5.3.2 Operation mode
The unit has four operation modes: Cool, dehumidifier, fan, sleep.
The unit working temperature under cooling mode is 61℉-95℉.
The unit working temperature under heating mode is 41℉-81℉.
A. Cooling your room
Select the cool mode to lower the temperature in your room.
Press MODE button repeatedly until the COOL indicator lights up.
Press Up/Down button to adjust the temperature which is displayed on the
screen.
The temperature can be set between 61℉ and 90℉.
Press SPEED button repeatedly until the desired fan speed indicator lights up.
To control the direction of the air flow horizontally, please adjust the inner
louver by hand.
Note : The air conditioner stops if the room temperature is lower than
selected temperature.
B. Heating your room (Optional for Heating Function Unit only)
Press MODE button repeatedly until the HEAT indicator lights up.
Press Up/Down button to set the temperature higher than the room temperature.
The fan speed can also be set.
Note: The drainage hose should be attached to the unit for continuous
operating.
C. Ventilating your room
Press MODE button repeatedly until the FAN indicator lights up.
In ventilation mode, the room air is circulated, but not cooled.
Press SPEED button repeatedly to select the fan speed as desired.
D. Drying your room
Press MODE button on the control panel or remote control, and the dry
indicator lights up. The fan speed is unable to be selected. User should
connect the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be
changed.
E. Sleep mode (this function can only be used with a remote control)
The sleep mode can be activated when in cool mode.
-
In cool mode:
After 1 hour the preset temperature is increased by 2℉, after another hour the preset temperature will again be increased by 2℉. -
In heat mode (Optional for Heating Function Unit only):
After 1 hour the preset temperature is decreased by 2℉, after another hour the preset temperature will again be decreased by 2℉.
Then the temperature is kept constant for 10 hours. And all the indicators dim to dark. The fan speed may switch over to low speed for silent operating and cannot be selected.
5.3.3 TIMER SETTING(1hour-24hours ):
The timer has two ways of operation:
To turn off (When power on)
Press Timer key to turn on the timer function.
Press Up /Down repeatedly to set the delay OFF time.
To turn on (When power off)
Press Timer key to turn on the timer function.
Press Up /Down repeatedly to set the delay ON time.
Cancel timer
Press Up /Down repeatedly until the LED shows ‘00’.
Note: when press POWER will also exit the timer setting.
5.3.4 Automatic Defrost
At low room temperatures, frost may build up at the evaporator during
operationThe unit will automatically start defrosting and the POWER LED will
start blinking. The defrost control sequence is as follows:
A. When the unit operates in the cooling and drying operation, and the ambient
temperature sensor senses the evaporator coil temperature is below 30℉, after
the compressor will stop operating for 10 minutes or the coil temperature up
to 44℉, the unit restart to cool operating mode.
B. When the unit operates in the drying operation, once the coil temperature
sensor senses the temperature of the evaporator is below 104℉ and the
differential temperature between coil temperature and room temperature isbelow
66℉ after the compressor operation for 20minutes, the unit start defrosting
for 5 minutes and the power indicator blinking.
5.3.5 Overload Protection
In the event of a power loss, there is a 3-minute delay to protect the
compressobefore it restarts.
5.4 DRAINAGE
Manual drainage:
-
When the machine stops after the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body. -
Place the water container below the side water outlet behind the body.
-
Unplug the water plug, the water will automatically flow into the water container.
Notes:
- Keep the water plug closed tight.
- During drainage, the body can be tilted slightly backwards.
- If the water container cannot hold all the water before the water container is full, plug the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
- When the water is discharged, stuff the water plug.
Notes: 1. Restart the machine after the water plug and drainage cover are installed, otherwise the water inside the machine will flow to the floor or the carpet.
Continuous drainage
The self-evaporating system uses the collected water to cool the condenser
coils for better efficient performance. There is no need to empty the drainage
tank in cooling operation except in drying operation and high humidity
conditions. The condensation water evaporates at the condenser and is
evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation, please
connect the attached drain hose to the unit. Condensation water can
automatically flow into a bucket or drain by gravity.
- Switch off the unit before operating.
- Remove the plug of the water outlet opening and keep itin safe area.
- Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
- Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
- Do not submerge the end of hose into water; otherwise, it can cause “Air Lock” in the hose.
To avoid water spillage:
- As the negative pressure of condensation drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
- Straighten the hose to avoid a trap existing in the hose.
CLEANING AND CARE
6.1. 1. CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow
reduces the efficiency of the system and if it becomes blocked it can cause
damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy
cleaning. Do not operate the unit without an air filter, or the evaporator may
be contaminated.
- Press POWER button to switch off the unit and unplug the power cord.
- Remove the filter mesh from the unit.
- Use a vacuum cleaner to suck dust from the filter.
- Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.
2. CLEANING UP OF REFRIGERANT
General Measures:
- Gas/vapor is heavier than air. It might accumulate in confined spaces, particularly at or below ground level.
- Eliminate every possible source of ignition.
- Use appropriate personal protection equipment (PPE).
- Evacuate unnecessary personnel, isolate, and ventilate the area.
- Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
- Prevent entry to sewers and public waters.
- Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
- Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.
TROUBLESHOOTING
Symptom | Inspection | Solution |
---|---|---|
The unit is not operating. | ✓Check the power connection is secure. | ➢ Insert |
the power cord securely into the wall outlet.
✓Check if the water level indicator lights up?| ➢ Empty the drain pan by
removing the rubber plug.
✓ Check the room temperature.| ➢The range of operating temperature is 41-95°F.
The unit works with reduced capacity.| ✓Check the air filter for dirt.| ➢Clean
the air filter as necessary.
✓Check if the air duct is blocked.| ➢To clear the obstacle.
✓ Check if the room door or window is open.| ➢ Keep the door and windows
closed.
✓ Check if the desired operating mode is selected
properly set. and the temperature is| ➢ Set the mode and temperature at proper
set-point according the manual.
✓ The exhaust hose is detached.| ➢Make sure the exhaust hose is securely
attached.
Water Leakage| ✓Overflow while moving the unit.
✓Check if the drain hose is kinked or bends.| ➢ Empty the water tank before
transport.
➢Straighten the hose to avoid a trap existing.
Excessive Noise| ✓Check if the unit is securely positioned.| ➢ Place the unit
on horizontal and firm ground.
✓ Check if there are any loose, vibrating parts.| ➢Secure and tighten the
parts.
✓ Noise sounds like water flowing.| ➢Noise comes from flowing refrigerant.
This is normal.
ErrorCode| E0| ✓ Communication faults between main PCB and display PCB.| ➢
Check the wire harness of the display PCB for damage.
---|---|---|---
E1| ✓ Ambient temperature sensor failure| ➢ Check connection or replace it.
To clean or replace the temperature sensor.
E2| ✓ Coil temperature sensor failures.| ➢ Check connection or replace it. To
clean or replace the temperature sensor.
Ft| ✓ Condensation water high level alarm.| ➢ Empty the drain pan by removing
the rubber plug.
DECOMMISSIONING
-
STORAGE
Long-Term Storage – If you will not be using the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit per the following steps:
1. Unplug the unit and remove exhaust hose and window kit store with the unit.
2. Drain the remaining water from the unit.
3. Clean the filter and let the filter dry completely in a shaded area.
4. Re-install the filter at its position.
5. The unit must be kept in upright position when in storage.
6. Preserving the machine in ventilating, dry, and safe place indoor.
ATTENTION:
The evaporator inside the machine must be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, to keep the inside of the body in a dry state and prevent it from mildewing. -
DISPOSAL
WARNING!! Releasing refrigerant into atmosphere is strictly forbidden! -
**** Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
Read User Manual Online (PDF format)