Flamco DN103-8 Heating Oil filter and Breather Instruction Manual

June 2, 2024
Flamco

Flamco DN103-8 Heating Oil filter and Breather

Flamco DN103-8 Heating Oil filter and Breather

Areas Of Application

  • Heating and drinking water with DVGW approval
  • High load capacity due to Simplex compression fitting technology
  • Flush-mounted use
  • For steel pipe according to DIN EN 10255

QR-Code

Only allow work on heating and domestic water systems to be performed by qualified personnel and in accordance with the respective applicable regulations, guidelines and rules of engineering.

Refer in particular to

DIN 1988 Technical rules for domestic water installations.

DIN 14336 Heating systems in buildings – Installation

DIN 18380 Heating systems and central hot water supply systems

EN 1717 Protection against pollution of domestic water

VDI 2035 Scale formation in domestic water heating systems and water heating systems

TrinkwV German Drinking Water Ordinance

BGV German Professional Association Regulations

Pipe Condition / Preparation

Pipe Condition / Preparation
Pipe Condition / Preparation

Montage

Installation preparation for adapter with male thread

Installation Preparation
Installation Preparation

  1. Insert pipe as far as the stop

  2. Tighten threaded adapter until hand-tight

  3. Withdraw pipe approx. 2 mm (for 2″ and 1 1/2″ approx. 7mm).
    Installation Preparation

  4. Tighten union nut, hold adapter in place when tightening.
    Installation Preparation

  5. Perform pressure test and flush pipe in accordance with DIN EN 1988.

Technical Data

Operating pressure 10 bar
Test pressure 15 bar
Operating temp. 110 °C, short-term 130 °C
Suitable pipes EN 10255 M – threaded steel pipe (medium)

EN 10255 H – threaded steel pipe (heavy)
Permissible media| Heating water in accordance with VDI 2035
Domestic water* in accordance with the German Drinking Water Ordinance (TrinkwV) Water with max. 50 % propylene glycol
Materials| Housing: Nickel-plated brass,
parts that come in contact with drinking water are left blank, Seal: EPDM

Installation Information

Nominal size of pipe| Diameter min. – max. [mm]| Recommended tightening torque [Nm]| Insertion depth Min. – max. [mm]
---|---|---|---
3/8″| 16,7 – 17,5| 30| 26 – 28
| | |
3/4″| 26,5 – 27,3| 60| 26 – 28
| | |
1 1/4″| 42 – 42,9| 130| 28 – 30
1 1/2″| 47,9 -48,8| 180| 35 – 65
2″| 59,7- 60,8| 200| 45 – 75

Important Installation Notice!

  • For the protection of the steel pipe adapter PLUS it has to be insulated professionally depending on the installation situation.
  • The insulation used and all other adhesives, additives and coatings have to be absolutely free of chlorine, ammoniac and nitrite.
  • The steel pipe adapter PLUS must not be exposed to environments containing chlorine, ammoniac or nitrite (e.g. stables, swimming pools, etc.).

Range Of Products

Art.| Version|
---|---|---
F13063| With Euro taper
Pipe 1/2″ x G3/4m
Euro taper|
F13064
F13065| For Euro taper
Pipe 3/8″, G3/4f Euro taper
Pipe 1/2″, G3/4f Euro taper|
F13077
F13078
F13080
F13081
F13082| With male thread,
self-tightening with
special thread seal
Pipe 3/8″ x G1/2m
Pipe 1/2″ x G1/2m
Pipe 3/4″ x G3/4m
Pipe 1″ x G1m
Pipe 1 1/4″ x G1 1/4m|
NEW
2023
F13083
F13084| With male thread
Pipe 1 1/2″ x R1 1/2
Pipe 2″ x R2|
F13090
F13091
F13092
F13093
F13094| With female thread
Pipe 3/8″ x G1/2f
Pipe 1/2″ x G1/2f
Pipe 3/4″ x G3/4f
Pipe 1″ x G1f
Pipe 1 1/4″ x G1 1/4f|

Customer Support

E info@simplex-armaturen.de
www.flamcogroup.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals