Flamco DN103-8 Heating Oil filter and Breather
Areas Of Application
- Heating and drinking water with DVGW approval
- High load capacity due to Simplex compression fitting technology
- Flush-mounted use
- For steel pipe according to DIN EN 10255
Only allow work on heating and domestic water systems to be performed by qualified personnel and in accordance with the respective applicable regulations, guidelines and rules of engineering.
Refer in particular to
DIN 1988 Technical rules for domestic water installations.
DIN 14336 Heating systems in buildings – Installation
DIN 18380 Heating systems and central hot water supply systems
EN 1717 Protection against pollution of domestic water
VDI 2035 Scale formation in domestic water heating systems and water heating systems
TrinkwV German Drinking Water Ordinance
BGV German Professional Association Regulations
Pipe Condition / Preparation
Montage
Installation preparation for adapter with male thread
-
Insert pipe as far as the stop
-
Tighten threaded adapter until hand-tight
-
Withdraw pipe approx. 2 mm (for 2″ and 1 1/2″ approx. 7mm).
-
Tighten union nut, hold adapter in place when tightening.
-
Perform pressure test and flush pipe in accordance with DIN EN 1988.
Technical Data
Operating pressure | 10 bar |
---|---|
Test pressure | 15 bar |
Operating temp. | 110 °C, short-term 130 °C |
Suitable pipes | EN 10255 M – threaded steel pipe (medium) |
EN 10255 H – threaded steel pipe (heavy)
Permissible media| Heating water in accordance with VDI 2035
Domestic water* in accordance with the German Drinking Water Ordinance
(TrinkwV) Water with max. 50 % propylene glycol
Materials| Housing: Nickel-plated brass,
parts that come in contact with drinking water are left blank, Seal: EPDM
Installation Information
Nominal size of pipe| Diameter min. – max. [mm]| Recommended tightening torque
[Nm]| Insertion depth Min. – max. [mm]
---|---|---|---
3/8″| 16,7 – 17,5| 30| 26 – 28
| | |
3/4″| 26,5 – 27,3| 60| 26 – 28
| | |
1 1/4″| 42 – 42,9| 130| 28 – 30
1 1/2″| 47,9 -48,8| 180| 35 – 65
2″| 59,7- 60,8| 200| 45 – 75
Important Installation Notice!
- For the protection of the steel pipe adapter PLUS it has to be insulated professionally depending on the installation situation.
- The insulation used and all other adhesives, additives and coatings have to be absolutely free of chlorine, ammoniac and nitrite.
- The steel pipe adapter PLUS must not be exposed to environments containing chlorine, ammoniac or nitrite (e.g. stables, swimming pools, etc.).
Range Of Products
Art.| Version|
---|---|---
F13063| With Euro taper
Pipe 1/2″ x G3/4m
Euro taper|
F13064
F13065| For Euro taper
Pipe 3/8″, G3/4f Euro taper
Pipe 1/2″, G3/4f Euro taper|
F13077
F13078
F13080
F13081
F13082| With male thread,
self-tightening with
special thread seal
Pipe 3/8″ x G1/2m
Pipe 1/2″ x G1/2m
Pipe 3/4″ x G3/4m
Pipe 1″ x G1m
Pipe 1 1/4″ x G1 1/4m|
NEW
2023
F13083
F13084| With male thread
Pipe 1 1/2″ x R1 1/2
Pipe 2″ x R2|
F13090
F13091
F13092
F13093
F13094| With female thread
Pipe 3/8″ x G1/2f
Pipe 1/2″ x G1/2f
Pipe 3/4″ x G3/4f
Pipe 1″ x G1f
Pipe 1 1/4″ x G1 1/4f|