  • ONLY use this device in compliance with all local and national laws and regulations concerning the use of crossbows and/or firearms.
  • NEVER direct this device towards the sun, a laser, or any other similarly intense light source.
  • NEVER direct your weapon—even an unloaded weapon—towards anything you are unwilling to kill or destroy.
  • ALWAYS make sure your weapon is completely unloaded before installing or removing this device. Remember to check the chamber.

Specifications

Housing Material 6061 Aluminum
Waterproof Rating IPX7
Rail Compatibility Picatinny, Weaver
Battery Type CR2032 (3V Lithium)
Magnification 1.5–5×
Compatible Crossbow Speeds 300–425 fps (92–129 m/s)

Adjustable Reticle

| Type| 20–100 Yard Bullet Drop Compensation (BDC)
Colours| Red, Green
Max. Elevation| 29½ MOA
Max. Windage| 15 MOA
Click Value| ½ MOA
Objective Lens Diameter| 1.25 in. (32 mm)
Overall Dimensions| 8.3×2.5×2.7 in. (21×6.5×7 cm)
Net Weight| 1.1 lb. (510 g)

Package List

Item Name Qty.
A Scope 1
B Mounts 2
C CR2032 Battery 1
D Allen Key 1
E Cleaning Cloth 1

Product Diagram

CVLIFE-1.5-5x32-Crossbow-Scope-Red-Green-fig-1

Installation

  1. Unscrew the Allen bolts from the mounts (B) using the provided Allen key (D) and disconnect the clamps from the bases.
  2. Unscrew the locking bolts from the bases and detach the removable legs.
  3. Fit the bases onto your weapon’s rail. Replace the removable legs and secure them with the locking bolts.
  4. Place the scope (A) onto the bases as shown, being sure its ocular lens faces your weapon’s stock. Open the lens covers and check that the scope’s placement will be comfortable during use. If not, move it along your rail as above.CVLIFE-1.5-5x32-Crossbow-Scope-Red-Green-fig-3
  5. Replace the clamps and Allen bolts onto the mounts, tightening these bolts with the Allen key until the scope is held firmly in place.CVLIFE-1.5-5x32-Crossbow-Scope-Red-Green-fig-4
  6. Remove the cap from the illumination adjustment knob on the left to expose the battery compartment. Install the provided battery (C), being sure the side marked + is facing up. Replace the cap, pressing and tightening until it locks itself in place.

Adjustment

  1. Remove the lens cover from around the ocular lens to expose the diopter adjustment ring. Open the lens cover for the objective lens. Turn the diopter adjustment ring until the reticle and field of view come into focus. Reattach the ocular lens cover.

  2. Adjust the reticle’s brightness and color as needed using the illumination adjustment knob on the left. Turning it towards you (clockwise) will first increase the brightness in the current color and then change to the next color, beginning at its lowest brightness. Turning it away (counterclockwise) will first decrease the brightness in the current color and then change to the next color, beginning at its highest brightness.
    Using the lowest illumination suitable for your environment will extend your battery life and minimize your eyes’ adjustment looking back and forth from your scope.

  3. Adjust the scope’s magnification by turning the magnification ring counterclockwise to zoom in or clockwise to zoom out. The magnification level is marked on the outside of the ring. The inside marks various fps speeds for easier pairing with a crossbow (1 foot ≈ 0.3 m).

  4. Adjust the scope’s vertical alignment by removing the top cap and turning the elevation adjustment knob. Turn clockwise if your weapon is striking high on your target. Turn counterclockwise if it is striking low. Each click is ½ MOA (¹⁄₁₂₀ degree) or about ½ inch at a range of 100 yards (1.5 cm at 100 m).CVLIFE-1.5-5x32-Crossbow-Scope-Red-Green-fig-6

  5. Adjust the scope’s horizontal alignment by removing the right cap and turning the windage adjustment knob. Turn the knob away from you (clockwise) if your weapon is striking too far to the right and towards you (counterclockwise) if it is striking too far to the left. Again, each click is ½ MOA or about ½ inch at 100 yards.

Maintenance

  • Clean the lenses of the scope as needed using the provided cloth (E) and gentle alcohol-free cleaning agents. The other exterior surfaces of the scope can be cleaned with any soft damp cloth. Do not use abrasive cleaners or caustic chemicals and do not allow any electronic component to become wet.
  • Check all parts of the scope for any wear or damage between uses. Repair or replace any problematic parts before further use.
  • If the scope will not be used for a prolonged period of time, clean it and replace all caps before storing in a cool dry place away from direct sunlight and inaccessible to children.