DORN BRACHT Ceiling Mounted Rough Flush Parts Instruction Manual
- June 13, 2024
- DORN BRACHT
Table of Contents
DORN BRACHT Ceiling Mounted Rough Flush Parts
Product Information
- Product Name: Dornbracht Montageanleitung
- Model Numbers: 35 033 970 90 / 35 033 970-90 0010 / 35 034 970 90 / 35 034 970-90 0010 / 35 043 970 90 / 35 043 970-90 0010 / 35 044 970 90 / 35 044 970-90 0010
- Weight
- 35 033 970 90 + 28 033 970-FF: 7 kg / 15.5 lbs (US)
- 35 043 970 90 + 28 043 980-FF: 7 kg / 15.5 lbs (US)
- 35 034 970 90 + 28 034 970-FF: 8 kg / 17.5 lbs (US)
- 35 044 970 90 + 28 044 980-FF: 8 kg / 17.5 lbs (US)
- CE Marking: Yes
- ZigBee Gateway Requirement: For model number 35 044 970-90 0010, a ZigBee Gateway should be provided on-site.
Product Usage Instructions
- General Safety Instructions:
- Pay attention to the warning symbol indicating the possibility of injuries or damages if safety instructions are not followed.
- Use suitable ladders or climbing aids when necessary.
- Electrical work should only be performed when the power is switched off.
- Read the manual and follow the instructions carefully.
- It is recommended to involve a system integrator recommended by Dornbracht.
- Technical Data: – The weight of each model variant is mentioned.
- Planning Guidelines: – For model number 35 044 970-90 0010, a ZigBee Gateway should be provided on-site.
- General Safety Instructions (English):
- Pay attention to the warning symbol indicating the possibility of death or serious injury if safety instructions are not followed.
- Pay attention to the caution symbol indicating the possibility of minor or moderate injury if safety instructions are not followed.
- Pay attention to the attention symbol indicating the possibility of property damages if instructions are not followed.
- Read the manual and follow the instructions carefully.
- All manuals and documents related to the product should be passed on to the end user to avoid limitations of producer liability in case of damage.
- For installation or operation-related questions, contact the Technical Service of Dornbracht using the contact details provided in the manual or on the Dornbracht website.
- Damages caused by non-compliance with instructions or improper use are excluded from warranty by Dornbracht.
- All plumbing work should be carried out by a competent and qualified plumber according to appropriate DIN/EN directives, national regulations, and regulations of local water supply companies.
- All electrical work should be carried out by a competent and qualified electrician installer according to appropriate DIN/EN directives, national regulations, and regulations of local power supply companies. – Follow local accident prevention regulations as a priority.
- Technical Data (English)
- No specific technical data is mentioned in this section.
Note: It is imperative to carefully read and comply with the user instructions. Non-compliance may result in Dornbracht AG & Co. KG rejecting any liability.
- No specific technical data is mentioned in this section.
General safety instructions
WARNING!
This symbol warns of the possibility of death or serious injury due to non-
compliance with the safety instructions.
CAUTION!
This symbol warns of minor or moderate injury due to non-compliance with the
safety instructions.
ATTENTION!
This symbol warns of property damages due to non-compliance with the
instructions.
NOTICE!
This symbol calls attention to important information.
Please read this manual and follow the instructions. All manuals and documents
belonging to the product have to be passed on to the end user. Otherwise the
producer liability may be limited in case of damage.
For questions or uncertainties regarding installation or operation, please
contact the Technical Service of Dornbracht. You can find relevant contact
details on the back of this manual and on the website of Dornbracht:
www.dornbracht.com
Damages caused by non-observance of the instructions or use not as intended
are excluded from warrenty by Dornbracht.
All work has to be carried out by a competent and qualified plumber according
to appropriate DIN / EN directives (DIN 1988, EN 1717, EN 806, TVO etc.),
national regulations and regulations of the local water supply companies.
All electrical work has to be carried out by a competent and qualified
electrician installer according to appropriate DIN / EN directives (VDE 0100
etc.), national regulations and regulations of the local power supply
companies.
Local accident prevention regulations are to be followed with priority.
Electrical work is to be carried out only under voltage free condition!
Attention!
It is imperative that you carefully read the following user instructions. In
the case of non-compliance Dornbracht AG & Co. KG rejects any liability.
Only use suitable ladders / climbing aids.
CAUTION!
Risk of cuts caused by sharp edges
Always wear safety gloves when carrying out the necessary work.
Do not allow other parts of your body (such as your head) to come into contact
with sharp edges.
- Elevate the injured part of the body.
- If necessary, clean and disinfect the cut and cover it with a sterile dressing.
- Any deep cut must be examined and treated promptly by a doctor.
- All more minor cuts should be examined by a doctor and treated if necessary.
Technical data
Weight
- 35 033 970 90 + 28 033 970-FF………………………………………………………7 kg / 15,5 lbs. (US)
- 35 043 970 90 + 28 043 980-FF………………………………………………………7 kg / 15,5 lbs. (US)
- 35 034 970 90 + 28 034 970-FF………………………………………………………8 kg / 17,5 lbs. (US)
- 35 044 970 90 + 28 044 980-FF………………………………………………………8 kg / 17,5 lbs. (US)
Weight, concealed rough parts
- 35 033 970 90……………………………………………………………………………….4,9 kg / 11 lbs. (US)
- 35 043 970 90……………………………………………………………………………….4,9 kg / 11 lbs. (US)
- 35 034 970 90……………………………………………………………………………….5,9 kg / 13 lbs. (US)
- 35 044 970 90……………………………………………………………………………….5,9 kg / 13 lbs. (US)
Weight, exposed trim parts
- 28 033 970-FF………………………………………………………………………………2,1 kg / 4,6 lbs. (US)
- 28 043 980-FF………………………………………………………………………………2,1 kg / 4,6 lbs. (US)
- 28 034 970-FF………………………………………………………………………………2,1 kg / 4,6 lbs. (US)
- 28 044 980-FF………………………………………………………………………………2,1 kg / 4,6 lbs. (US)
- 28 0XX 9X0-FF
- Maximum flow at a flow pressure of 300 kPa / 45 psi / 3 bar
- Spray (Headshower) …………………………………………………………………………..6 l/min / 1,8 gpm
- Rain (Bodyshower) …………………………………………………………………………..12 l/min / 3,2 gpm
Electrotechnical data
- 35 034 970 90 + 28 034 970-FF
- 35 044 970 90 + 28 044 980-FF
Primary connection data
- Nominal voltage……………………………………………………………………………………100 – 240 V AC
- Frequency………………………………………………………………………………………………….50 – 60 Hz
- Nominal power……………………………………………………………………………………………….. < 28 W
- Standby-power…………………………………………………………………………………………………. < 2 W
Ceiling module
- Supply voltage………………………………………………………………………………………………. 12 V DC
- Ambient temperature…………………………………………………………………………≤ 40 °C / ≤ 104 °F
- Relative humidity
Light source
- Technology………………………………………………………………………………………………LED (RGBW)
- Degree of protection…………………………………………………………………………………………… IP X5
- Compatibility………………………………………………………………………………………ZigBee Light Link
- Marking………………………………………………………………………………………………………………..CE
- Dornbracht recommends consulting a system integrator.
- Dimensions can be found at the end of the manual
Planning notes
Ceiling module
Ceiling construction with sufficient load carrying capacity for the permanent
attachment of the appliance (weight: 8 kg / 17,5 lbs. (US)). The fasteners
included in the scope of delivery are only suitable for fixing in concrete.
Operating conditions
Permissible operating temperatures:
- Cold water temperature……………………………………………………………….. 5 – 25 °C / 41 – 77 °F
- Recommended cold water temperature………………………………………………………. 15 °C / 59 °F
- Hot water temperature…………………………………………………………… 50 – 65 °C / 120 – 149 °F
- Recommended hot water temperature…………………………………………………≤ 60 °C / ≤ 140 °F
Flow pressure:
- min. flow pressure………………………………………………………………………..100 kPa / 15 psi / 1 bar
- max. flow pressure……………………………………………………………………….500 kPa / 15 psi / 5 bar
- Recommended flow pressure………………………………………………………300 kPa / 44 psi / 3 bar
Water hardness:
- Recommended water hardness: 6 – 7 °dH / 107 – 125 ppm CaCO3 / 7.5 – 8.8 °e / 10.7 – 12.5 °fH
If the water is harder, a water softener is to be installed in the main cold water supply line.
Drainage:
Drainage capacity / drain connection value [DU value]
- 28 0XX 9X0-FF………………………………………………………………………………………. 0,3 l/s / 0,06 gps
- 28 0XX 9X0-FF 0010………………………………………………………………………………. 0,06 gps / 0,3 l/s
Electrical information (35 0XX 970 90 / 0010):
Observe the regulations for protection zones according to DIN VDE 0100, Part
701 (IEC 60364-7-701). Please conform to national statutory regulations, where
different. The following electrical components must be installed outside
safety zones 0 – 2: Power supply accessible (revision). The product must be
permanently connected to fixed conductors.
Provided by customer:
It is essential to ensure that the product can be completely disconnected from
the mains.
- Residual current device
- Overcurrent protection device
- The customer must provide a ZigBee gateway for items 35 034 970 90, 35 034 970-90 0010, 35 044 970 90 and 35 044 970-90 0010.
Dimension
Electrical information (35 034 970 90 / 0010, 35 044 970 90 / 0010) Observe the regulations for protection zones according to DIN VDE 0100, Part 701 (IEC 60364-7-701).
Planning notes
35 033 970 90 / 35 033 970-90 0010
35 043 970 90 / 35 043 970-90 0010
35 034 970 90 / 35 034 970-90 0010
35 044 970 90 / 35 044 970-90 0010
35 034 970 90 / 35 034 970-90 0010
35 044 970 90 / 35 044 970-90 0010
Required tools
Parts supplied
ROW – Rest of World
US / CA – United States / Canada
US / CA – United States / Canada
ROW – Rest of World
US / CA – United States / Canada
ROW – Rest of World
US / CA – United States / Canada
Assembly
Technical Information
Dornbracht AG & Co. KG
Köbbingser Mühle 6, D-58640 Iserlohn
Tel. +49 2371 8899-900
mail@dornbracht.de
www.dornbracht.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>