PETSITE 9000 BTU Portable Air Conditioner Instruction Manual

May 15, 2024
PETSITE

PETSITE 9000 BTU Portable Air Conditioner

Features and Components

  1. Features

New look, compact structure, streamlined machine, aristocratic atmosphere. With cooling,dehumidification and fan function, Continuous Water Drainage Functions. LED displays the control panel. The machine is beautiful and elegant. High-quality remote control is equipped to facilitate operation. It adopts a user-friendly remote control design.  Outdoor interface is set high to facility assembly and keep the smoothflow of the heat pipe. Air filtration capability.Timing switch function, Protection function of automatically restarting the compressor after three minutes, a variety of other protection functions.

Components

Components

Components

Components

Installation and Adjustment

Installation

Warning: before using the mobile air conditioning, keep it upright for at least two hours.

The air conditioning can be easily moved in the room. In the moving process, ensure that the air conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do not install and use the air conditioning in the bathroom or other humid environments.

1.1 Install the pipe assembly (as shown in Fig.1): screw the pipe assembly (exhaust fitting end) into the exhaust port on the rear panel.

Installation and Adjustment

Installation and Adjustment

Install the window sealing plate assembly

  1. Half open the window, and mount the window sealing plate assembly to the window (as shown in Fig.2 and Fig.3); the assembly can be placed in horizontal and vertical direction.
  2. Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.

Install the body

  1. Move the machine with installed pipe and fittings to the window,  and the distance between the body and walls or other objects shall be least 50cm/20” (as shown in Fig.4)
    Installation and Adjustment

  2. Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly (as shown in Fig.5 and Fig.6).

Notes:

  1. The flat end of the exhaust pipe joints must be snapped into place.
  2. The pipe cannot be distorted nor has substantial turning (more than 45 °). Keep the ventilation of the exhaust pipe not blocked.

Important Notice

The length of the exhaust hose shall be 280mm-1500mm/ 11”-59”, and this length is based on the specifications of the air conditioning. Do not use extension tubes or replace it with other different hoses, or this may cause a malfunction. Exhaust host must be not blocked; otherwise it may cause overheating.

Control Panel Setting

Operating instructions:

LED Control Panel is as follows:

Control Panel Setting

  1. Power Key
  2. Mode Selection Key
  3. Sleep Key
  4. Down Key
  5. Up Key
  6. Fan Speed Selection Key
  7. Timer Key

In the cooling mode, press the UP and Fan Key to turn on the sleep mode,then the unit will work quietly in energy-saving mode.

  1. When the machine is powered on for the first time, the buzzer will play power-on music, and then the machine will get into standby status.

  2. Power Key: press the key to turn on and turn off the machine. In the case of power on, press the key to turn off the machine; in the case of power off, press the key to turn on the machine.

  3. Mode Selection Key: In the case of power on, press the key to switch between cool → fan → dry mode.

  4. Up Key and Down Key: press the two keys to change the setting temperature or setting time, operate as follows: While setting temperature, press up key or down key to select the required temperature (not available in fan or dry mode). While setting time, press up key or down key to select the required time. 5: Wind
    Speed Selection Key:

  5. In cooling and fan mode, press the key to select high,low wind speed operation. But limited by anti-cold conditions, under certain conditions, it may not run according to the set wind speed. In dehumidifying mode, pressing the key is invalid, and the fan will forcibly choose low wind speed operation.

  6. Timer Key:
    In the case of power on, press the key to close timer; in the case of power off, press the key to open timer. Press the key, when the timer symbol flashes, press up and down key to select the required timer value. Timer values can be set in 1-24 hours and the timer value is adjusted upor down by one hour.

  7. Sleep Mode:

Note:

  1. Do not turn on the sleep mode in the dry or Fan mode!
  2. The waterfall lamp will turn on and buzzer will alarm for several second, the compressor will stop to work when the inner unit chassis water is full

Operating Instructions of the Remote Control

The remote control panel is as follows:

Operating Instructions of the Remote Control

Instructions of key operation of the high-quality remote control are as follows:

  1. Power: Press  Symbol the key to turn on or turn off the machine.
  2. Timer: press  Symbol the key to set time.
  3. Down: press   the key to reduce temperature and timing setting.
  4. Mode: press Symbol  the key to switch between cooling, fan, dehumidifying mode.
  5. Up: press   the key to increase temperature and timing setting.
  6. Fan: press  the key to select high, low wind speed.
  7. Sleep Mode: Press   the key to turn on the sleep mode.

A Variety of Protection Functions

3.1 Frost Protection Function:
In cooling, dehumidifying or energy-saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation.

3.2 Overflow Protection Function:

When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the “FULL” indicator light will flash. At this point, you need to move the drainage pipe connected  the machine or the water outlet to sewer or other drainage area for drainage(refer to Drainage Instructions at the end of this chapter for detail) for details. After the water is emptied, the machine will automatically return to the original state.

3.3 Automatic Defrosting (cooling mode has this function): The machine has automatic defrosting function.

3.4. Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay start protection function after the compressor is turned off.

Drainage Instructions

Manual drainage:

  1. When the machine stops after the water is full, turn off the machine power and unplug the power plug.
    Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.

  2. Place the water container below the side water outlet behind the body.

  3. Unscrew the water plug, the water will automatically flow into the water container.

Notes:

  1. Keep the water plug properly.
  2. During drainage, the body can be tilted slightly backwards.
  3. If the water container cannot hold all the water, before the water container is full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
  4. When the water is discharged, stuff the water plug up.

Notes:

  1. Restart the machine after the water plug is installed, otherwise condensate water of the machine will flow to the floor or the carpet.
    Drainage Instructions

  2. Continuous drainage (Optional) (only applicable to dehumidifying mode), as shown in figure:

  3. Unplug the water plug on.

  4. Set the drainage pipe into the water outlet.

  5. Connect the drainage pipe to the bucket.
    Drainage Instructions

Maintenance

Cleaning: before cleaning and maintenance, turn off the machine and unplug the plug.

  1. Clean the surface Clean with surface of machine with a wet soft cloth. Don’t use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise,the surface of the air conditioning will be damaged or even the whole machine will be damaged.
  2. Clean the filter screen If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.

2.1: Clean the upper filter screen frame

  1. Clasp the wedging block of the EVA filter screen frame with hands. Force down from the outside to remove the EVA filter screen frame. Unscrew four screws fixing the EVA filter screen and the rear housing to remove the EVA filter screen (as shown in the above figure) .
  2. Put the EVA filter screen into warm water with neutral detergent (about 40℃ / 104℉) and dry it in the shade after rinsing clean
    Drainage Instructions

Unit Storage:

  1. Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers.
  2. Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
  3. Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the water plug and the drainage cover.
  4. Remove the exhaust pipe and keep it properly.
  5. Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the reach of children, and take dust control measures.
  6. Remove batteries of the remote control and keep them properly.
    Note: ensure that the body is placed in a dry place and keep all machine components properly.

Troubleshooting

Do not repair or disassemble the air conditioning by yourself. Unqualified repair will cause damage to users or their properties.

Problems Reasons Solutions
The air conditioning does not work. There is no electricity. Turn it on

after connecting it
to a socket with electricity
The overflow indicator
displays “FL”.| Discharge the water inside.
The ambient temperature is too low or too high| Recommend to use the machine in at the temperature of 7-35 ℃ (44-95 ℉).

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals