PRODUCT OVERVIEW

PRODUCT DIAGRAM
PRODUCT DIAGRAM

1 Control panel 5 Caster
2 Air outlet with adjustable louver 6 Drainage hole
3 Handle 7 Air exhaust
4 Air inlet with air filter

Note: The appearance is only for reference. Please see the real product for detailed information.

FEATURES

  • √ High capacity in a compact size with fan, cooling and dehumidifying function.
  • √ Temperature setting and display
  • √ LED Digital display
  • √ Electronic control with built-in timer, sleep mode
  • √ Self-evaporating system for better efficient
  • √ Auto shut off when tank full
  • √ Automatic restart in the event of power outage
  • √ Auto defrosting function at low ambient temperatures
  • √ Remote control
  • √ 2-speed fan
  • √ Casters for easy mobility

INSTALLATION

UNPACKING

  • Unpack the carton and take the appliance and accessories out.
    Check the device after unpacking for any damage or scratches on it.

Accessories:

  1. Exhaust hose

  2. Hose connector

  3. Window kit adapter

  4. Remote control

  5. Drain pipe

  6. Window kit

Choose your location

  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.

  • Place the unit on a firm, level surface in an area with at least 1.65ft(50cm) of free space around it to allow for proper air circulation.
    walls

  • Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.

  • Never install the unit where it could be subject to:

★ Heat sources such as radiators, heat registers, stoves or other products that produce heat.
★ Direct sunlight
★ Mechanical vibration or shock
★ Excessive dust
★ Lack of ventilation, such as cabinet or bookcase
★ Uneven surface

WARNING!
Install the unit in rooms which exceed 43sq.ft(4 m²).
Do not install the unit in a place where inflammable gas may leak.

NOTE!
The manufacturer may provide other suitable example or may provide additional information about the refrigerant odour.

ATTACH THE EXHAUST HOSE
The air conditioner needs to be ventilated to the outside so that the air containing waste heat and moisture discharged from the appliance can be discharged from the room.
Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low back pressure.

Step 1:
Connect the hose connector to one end of the exhaust hose.

Step 2:
Connect the windows kit adapter to the other end of the exhaust hose.

Step 3:
Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.

Step 4:
Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.

Step 5:
Attach the hose connector to the exhaust air outlet of unit.

Step 6:
Adjust the length of the flexible exhaust hose, to make sure the distance between the unit and the window will be more than 27.6inches (70cm), height from exhaust hose to the floor will be more than 35.4inches(90cm). And avoid bends in the hose. Then place AC near an electrical outlet.
flexible exhaust
Step 7:
Adjust the louver at the air outlet, and then switch on the unit.

OPERATION

CONTROL PANEL AND DISPLAY
CONTROL PANEL AND DISPLAY

1 POWER Press to switch the machine on or off
2 MODE Press to switch the operation mode between fan, cooling and

dehumidifier
3| SPEED| Press to switch the fan speed between HIGH and LOW
4| DOWN| Decrease the desired temperature or timer setting
5| UP| Increase the desired temperature(16℃~32℃) (61℉~90℉) or timer setting
6| TIMER| Sets a time for the unit to automatically start or stop.
7| LOCK| Long press to turn on or turn off the child lock function
8| SLEEP| Press to turn on sleep mode or off
9| LED Display| Display timer setting and room temperature

REMOTE CONTROL
REMOTE CONTROL

SETTINGS
Start-up and Shutdown
Press POWER to turn the unit on.
Press MODE button to select the desired operation mode.
Press POWER again to turn off the power.
Operation mode
The unit has four operation modes: Fan, Cool, Dehumidifier, Sleep.
The unit working temperature under cooling mode is 16℃-35℃/61℉-95℉.
A. Cooling your room
Select the cool mode to lower the temperature in your room.
Press MODE button repeatedly until the Cool indicator lights up.
Press Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between 16℃/61℉ and 32℃/90℉.
Press SPEED button repeatedly until the desired fan speed indicator lights up.
To control the direction of the air flow horizontally, please adjust the inner louver by hand.
Note: The air conditioner stops if the room temperature is lower than selected temperature.
B. Ventilating your room
Press MODE button repeatedly until the FAN indicator lights up.
In ventilation mode the room air is circulated, but not cooled.
Press SPEED button repeatedly to select the fan speed as desired.
C. Drying your room
Press MODE button on the control panel or remote control, the dry indicator lights up. The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be selected.
D. Sleep mode
The sleep mode can be activated when in cool mode.

  • In cool mode:

After 1 hour the preset temperature is increased by 1℃, after another hour the preset temperature will again be increased by 1℃.
TIMER SETTING (1 hour – 24 hours) :
The timer has two ways of operation:

To turn off (When power on)| | Press Timer key to turn on the timer function| | Press Up /Down repeatedly to set the delay OFF time
---|---|---|---|---
To turn on (When power off)| | Press Timer key to turn on the timer function.| | Press Up /Down repeatedly to set the delay ON time
Cancel timer| | Press Up / Down repeatedly until the LED shows ‘00’.
Note: when press POWER will also exit the timer setting.

Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation. The unit will automatically start defrosting and the POWER LED indicator will flash. The defrost control sequence is as follows:
A. When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below -1°C(30℉). When the compressor stops operating for 10 minutes or the coil temperature up to 7°C(44℉), the unit will restart to cool operating mode.
B. When the unit operates in the heating operation, drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40°C/104℉ and the differential temperature between coil temperature and room temperature is below 19°C/66℉ after the compressor operation for 20minutes, the unit start defrosting for 5 minutes and the power indicator will flash.
Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarts.

DRAINAGE

Manual drainage:

  1. When the machine stops after the water is full, please unplug the power plug.
    Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.

  2. Place the water container below the side water outlet behind the body.

  3. Unplug the water plug, the water will automatically flow into the water container.

Notes:

  1. Keep the water plug properly.
  2. During drainage, the body can be tilted slightly backwards.
  3. If the water container cannot hold all the water, before the water container is full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
  4. When the water is discharged, stuff the water plug.
    Notes: 1. Restart the machine after the water plug and drainage cover are installed, otherwise condensate water of the machine will flow to the floor or the carpet.

plug properly

Continuous drainage

The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. There is no need to empty the drainage tank in cooling operation, except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and is evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation, please connect the attached drain hose to the unit. Condensate water will automatically flow into a bucket or drain by gravity.

  • Switch off the unit before operating.
  • Remove the plug of the water outlet opening, and keep it in safe area.
  • Securely and properly connect the drain hose and make sure that it is not kinked and clear of obstruction.
  • Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
  • Do not submerge the end of hose into water; otherwise it can cause “Air Lock” in the hose.

operating

To avoid water spillage:

  • As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
  • Straighten the hose to avoid a trap existing in the hose.

CLEANING AND CARE

CLEANING THE AIR FILTER (every two weeks)
To avoid water spillage:

As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.

Straighten the hose to avoid a trap existing in the hose.
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system, and if it becomes blocked, it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

  1. Press POWER button to switch off the unit and unplug the power cord.
  2. Remove the filter mesh from the unit.
  3. Use a vacuum cleaner to suck dust from the filter.
  4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.

Switch off the unit and remove the air filters.
Rinse the air filter under running water.

Warning!!!
Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers.

CLEANING UP OF REFRIGERANT

General Measures:

  1. Gas/vapor is heavier than air. May accumulate in confined spaces, particularly at or below ground level.
  2. Eliminate every possible source of ignition.
  3. Use appropriate personal protection equipment (PPE).
  4. Evacuate unnecessary personnel, isolate, and ventilate area.
  5. Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
  6. Prevent access to sewers and public waters.
  7. Stop the source of the release, if it is safe to do so. Consider the use of water spray to disperse vapors.
  8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact local competent authorities after a spill.

TROUBLESHOOTING

©√ Check if the desired operating mode is selected and the temperature is properly set.Water Leakage√ Overflow whilemoving the unit.Excessive Noise√ Check if the unit issecurely positioned.©

Symptom| Inspection| Solution|
---|---|---|---
The unit is not operating.| √ Check the powerconnection in secure.|

  • Insert the power cord securely into the wall outlet.

|
√ Check if the waterlevel indicator lights up.|

  • Empty the drain pan by removing the rubber plug.

|
√ Check the roomtemperature.|

  • The range of operating temperature is5-35℃(41℉~95℉).

|
The unit works with reduced capacity.| √ Check the air filterfor dirt.|

  • Clean the air filter as necessary.

|
√ Check if the air ductis blocked.|

  • To clear the obstacle.

|
√ Check if the roomdoor or window is open.|

  • Keep the door and windows closed.

|
■      Set the mode and temperature at proper set-point according to the manual.|
√ The exhaust hose isdetached.|

  • Make sure that the exhaust hose is securely attached.

|
■      Empty the water tankbefore transport.|
√ Check if the drainhose is kinked or bent.|

  • Straighten the hose

to avoid a trap existing.

|
■      Place the unit on horizontal and firm ground.|
√ Check if there are any loose or vibrating parts.|

  • Secure and tighten the parts.

|
√ Noise sounds likewater flowing.|

  • Noise comes from flowing refrigerant. This is normal.

|
Error Codes| E0| √ Communication faults between main PCB and display PCB.|

  • Check the wire harness of the display PCB for damage.

E1| √ Ambient temperature sensor failure.|

  • Check connection or replace it. To clean or replace the temperature sensor.

√ Coil temperature| ■  Check connection or
E2|

  • sensor failures.

|

  • replace it. To clean or eplace the temperature

| | sensor.
| √ Condensate water|

  • Empty the drain pan

Ft| high level alarm.| by removal of the rubber
| | plug.

DECOMMISSIONING

STORAGE

Long-Term Storage – If you will not use the unit for an extended period of time (more than a few weeks) it is best to clean the unit and dry it out completely. Please follow the steps below to store the unit:

  1. Unplug the unit and remove exhaust hose and window kit for storage with the unit.
  2. Drain the remaining water from the unit.
  3. Clean the filter and let the filter dry completely in a shaded area.
  4. Re-install the filter in place.
  5. The unit must be kept in upright position when in storage.
  6. Preserve the machine in ventilating, dry, non- corrosive gas and safe indoor place.

ATTENTION:
The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.