HURRIKAN OL50-D056CW Commercial Dehumidifier Instruction Manual

May 15, 2024
HURRIKAN

HURRIKAN logo INSTRUCTION MANUAL
OL50-D056CW

NEW Version

OL50-D056CW Commercial Dehumidifier

COMMERCIAL DEHUMIDIFIER

HURRIKAN OL50 D056CW Commercial Dehumidifier - Symbol
1

Please read this manual before operating and save it for future reference. Every dehumidifier is covered with a 1-year free warranty offered by Hurrikan that
is automatically valid from the date of purchase. To extend the warranty or express any questions or concerns, please email us at support@hurrikan.us

HURRIKAN’s STORY
Hurrikan is an American luxury home appliance and specialty retailer headquartered in New York City. In 2022, Hurrikan introduced the industry- leading commercial dehumidifier as we know it today. We’re proud to build on our legacy as the leader in dehumidifier traceability with responsibly sourced, expertly crafted dehumidifiers that celebrate technology in all its forms.

Our   Origin
The outbreak of COVID-19 in early 2020 brought an online shopping boom and a new lockdown lifestyle, consequently increasing the demand for large buildings for either storage or dwelling needs. As a household dehumidifier manufacturer ourselves, we sensed the pressing need for commercial dehumidifiers that could maintain an appropriate humidity condition for good storage or living. Therefore, we started to extend beyond producing household dehumidifiers into the commercial field, in an attempt to not only create a solution but to also challenge the monotonous designs embodied by the existing commercial dehumidifiers.
To convey our message, we blended in a touch of creativeness into the appliances’ designs. We drew inspiration from luxury clothing, and therefore, elegance and boldness had become our antithesis to appliances’ predominating tedious design. With the brand concept “sweep away the unwanted”, we hope to invigorate everyone not to be bothered by the depressing moments, but instead to boldly overcome whatever that comes before us.

Our Style
Guided by our unique perspective, we challenge commercial dehumidifiers’ predominant boring design, adopting boldness in our product design instead. Specifically, we hope to make our product “sweep away the unwanted”by integrating high-performance components. Our Hurrikan is unique for achieving a balance between appearing elegant and being powerful. Hurrikan represents a revolution: the brand transforms a field that was previously cumbersome into a stage for boldness, bringing new aesthetic standards to appliance design.

Our Logo
Hurricane is central to Hurrikan’s product designs: it epitomizes nature’s almighty force and symbolizes the perpetual pursuit of power, clearness, and relentlessness. Hurrikan’s logo design thus resembles tornado, bearing an elegantly modest but implicitly robust appearance. Hurricane as the design element also perfectly aligns with Hurrikan’s ideal-to lead a vigorous, bold, and cleansed life.

Cautions

Please read this manual carefully before operating and keep it for further reference!
If you have any questions, please contact us at support@hurrikan.us for help.

BEFORE YOU BEGIN
This commercial dehumidifier removes excess moisture from storage spaces and large buildings.
The environmentally friendly R32 is used as the refrigerant. R32 has no damaging influence on the ozone layer (ODP), has a negligible greenhouse effect (GWP), and is available worldwide. Because of its efficient energy properties, R32 is highly suitable as a coolant for this product. Precautions must be taken into consideration due to the coolant’s flammability.

IMPORTANT SYMBOLS

| This unit uses a flammable refrigerant.
If the refrigerant leaks or comes in contact with fire or a heating source,it will create harmful gas and there will be a risk of fire.
---|---
| Read the INSTRUCTION MANUAL carefully before operation.
| Service personnel are required to carefully read the INSTRUCTION MANUAL before operation.

This instruction manual contains instructions and notes on the operation and use of this unit.
Do not use unofficial components or accessories that may result in a risk of fire, electric shock, or injury to people.
For your safety and benefit, please keep this manual handy for future reference.

THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

  • This appliance can be used by children older than eight, people with reduced physical, sensory, or mental capabilities, and people who lack experience and knowledge if they have been given supervision or instruction concerning the use of this product in a safe way, and if they understand the hazards involved. Children shall not play with this appliance. Cleaning and maintenance should not be done by children without supervision.
  • This appliance is designed to be used indoors, not outdoors.
  • This appliance is designed for using R32 (propane) gas as the designated refrigerant only.
  • The refrigerant loop is sealed. Only a qualified technician should attempt to service.
  • Do not discharge the refrigerant into the atmosphere.
  • R32 (propane) is flammable and heavier than air. It accumulates first in low areas but can be circulated by the fans.
  • If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
  • The propane gas used in this appliance has no odor.
  • The lack of smell does not indicate a lack of escaped gas.
  • If a leak is detected, immediately evacuate all people from the indoor space. Ventilate the room and contact the local fire department to inform them about the propane leakage.
  • Do not let any person back into the space until qualified service technicians have arrived and informed that it is safe now to return to the space.
  • No open flames, cigarettes, or other possible sources of ignition should be used inside or in the vicinity of this appliance.
  • This appliance’s components are designed for propane and the non-incentive and non-sparking conditions. Components should only be replaced with identical parts.
  • FAILURE TO ABIDE BY THIS SAFETY WARNING LIST MIGHT RESULT IN AN EXPLOSION, DEATH, INJURY, OR PROPERTY DAMAGE.

IMPORTANT SAFETY TIPS
Your safety is the most important thing we concern!
WARNING: Please read the following tips carefully and fully understand them before operating your appliance.

OPERATIONAL PRECAUTIONS
WARNING: to reduce the risk of fire, electric shock, or injury to people or property:

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified people to avoid any hazard.
  • This appliance should be disconnected from its power source during service.
  • Always operate the unit from a power source of equal voltage, frequency, and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the appliance.
  • Do not immerse or expose the unit to rain, moisture, or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet/outlet.
  • Do not operate the appliance if it is dropped, damaged, or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed in accordance with national wiring regulations.
  • Do not use means other than those recommended by the manufacturer to accelerate the defrosting process or to clean.
  • The appliance shall be stored in a room without continuously operating sources. (for example: open flames, operating gas appliances, or operating electric heaters.)
  • The appliance shall be stored in the way that prevents mechanical damage.
  • Do not piece or burn the unit, even after use.
  • Be aware that refrigerants may not have odor.
  • Pipework shall be protected from physical damage and shall not be installed in an unventilated space that is smaller than 4 m².
  • Comply with national gas regulations.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

WARNING
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.

WARNING
Servicing shall only be performed as recommended by the manufacturer.
Maintenance and repair that require the assistance of other skilled personnel shall be carried out under the supervision of a person competent in the use of flammable refrigerants.

SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when servicing an appliance with R32.

  1. Area safety check
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to minimize the risk of ignition. Prior to repairing the refrigerating system, the following precautions shall be complied.

  2. Work procedure
    Work shall be undertaken under a controlled procedure to minimize the risk of exposure to a flammable gas or vapor during the process.

  3. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by the control of flammable material.

  4. Checking for the presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during the work, to ensure the technician’s awareness of potentially flammable atmosphere. Ensure that the leak detection equipment used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

  5. Presence of fire extinguisher
    If any high-temperature operation is to be conducted on the refrigeration equipment or any of its associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  6. No ignition sources
    Don’t carry out work in relation to a refrigeration system that is exposed to any pipework that contains flammable refrigerant using any sources of ignition in order to avoid the risk of fire or explosion. All possible ignition sources, including cigarette, should be kept far away from the site of installation, repairing, removing, and disposal. Prior to work, ensure that the surrounding area has no flammable hazard or ignition risks, and the “No Smoking” sign shall be displayed.

  7. Ventilated area
    Ensure that the area is open or adequately ventilated before breaking into the system or conducting any high-temperature operation. Please keep ventilation during the process. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

  8. Refrigeration equipment check
    When electrical components are being changed, they shall be suitable for the purpose and be aligned with the correct specification according to the maintenance and service guidelines. If you encounter any problem, please feel free to consult the manufacturer for assistance. The following checks shall be applied to installations using flammable refrigerants:
    -The charge size is in accordance with the room size within which the refrigerant-containing parts are installed.
    -The ventilation machinery and outlets are operating adequately and are not obstructed.

PRODUCT DESCRIPTION

The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.
2.1 FEATURES

|
---|---
Powerful and Efficient moisture removal| Two modes: Intelligent & Continuous
|
Two drainage methods: Automatic/Pump & Manual| Humidity Monitor showing current air humidity
|
Temperature Monitor showing current ambient temperature| A 24-hour timer for automatic operation time setting
|
Air Filter for dust removal| Quiet fan for quiet operation

2.2 PARAMETERS

Model OL50-D056CW Refrigerant/Charge R410a /11.6oz
Power Supply 115V~60Hz Low Side Pressure 240psi
Dehumidification Capacity 42Pints/D (65℉/60%RH)

70Pints/D (80℉/60%RH)
110Pints/D (86℉/80%RH)| High Side Pressure| 522psi
BCSC| 15A
Rated Input Power  & Current| 635W/5.05A (80℉/60%RH)
728W/6.75A (86℉/80%RH)| Compressor Input| RLA:6.4A/LRA:38A
Fan Motor Power| 0.100HP

2.3. PRODUCT DISPLAY

HURRIKAN OL50 D056CW Commercial Dehumidifier - PRODUCT
DISPLAY

OPERATION

HURRIKAN OL50 D056CW Commercial Dehumidifier - BUTTONS

3.1. BUTTONS

| POWER
Press this button to turn the unit on/ off. The screen will light up to show the current ambient humidity level when the unit is on. The default setting for mode and humidity level are: continuous and 50%.
NOTE: The pump will keep operating if it hasn’t finished draining when the unit is turned off, and will shut down after it finishes.
---|---
| DRAIN
Press this button to activate pump drainage. The pump will operate for 30 seconds and automatically turn off.
| CONT
In the intelligent dehumidification mode, press this button to switch to the continuous dehumidification mode. The set humidity level is unadjustable under this mode, and the machine will operate continuously regardless of the ambient humidity level.
In the continuous dehumidification mode, press this button to switch to the intelligent dehumidification mode, where the set humidity level is adjustable.
| MINUS
Each press of this button will decrease the set humidity level/timer by 5 %/1 hour within the range of 20-90%/0-24 hours.
| ADD
Each press of this button will increase the set humidity level/timer by 5 %/1 hour within the range of 20-90%/0-24 hours.
| TIMER
The first press of this button will turn the timer on, and the timer indicator will light up. Press the “ADD” or “MINUS” button to increase or decrease the timer within a 24 hour time frame.
In the power-on state, the timer indicates the length of operation time.
In the standby state, the timer indicates the length of time until the reserved turning-on time. The timer is memoryless, so it needs to be reset each time.
A long press (5 seconds) of this button will temporarily switch the screen from displaying humidity level to displaying ambient temperature.

NOTE:
The dehumidifier starts operating in the mode that it was last in.
he dehumidifier starts dehumidifying if the room humidity level is 3% higher than the set humidity level, and stops if the room humidity level is 3% lower than the set humidity level.

3.2. INDICATORS

| : Water Full Indicator| | : Continuous Mode Indicator
---|---|---|---
| : Defrosting Indicator| | : Timer Indicator

DRAINAGE

Automatic/Pump Drainage

  • Take off the screw blocking the drain hole for automatic/pump drainage, which is located on the dehumidifier’s side panel.
  • Plug a PVC drain hose through the screw into this hole to enable automatic drainage. You may connect the other end of the hose to any drainage area.
  • The pump will automatically drain off water when its tank is full.
  • Pressing the “DRAIN” button can drain off water regardless of the tank’s status (even when the tank isn’t full). The pump will operate for 30 seconds and automatically shut down. Repeatedly press this button to drain the unit completely.

WARNING: the end of the hose should not be submerged in water to prevent it from being blocked or damaged.
If the drain is located above the dehumidifier, the maximum capacity of the water pump is 5 m. If the water is drained downwards, there is no limit for the distance. The width of the water hose is 12 mm.

MAINTENANCE

5.1. CLEANING

  1. Body Cleaning
    Use a soft and slightly moist cloth to clean the dehumidifier’s body. Do not use cleanser, steel balls, chemically treated dust-proof cloth, gasoline, benzene, thinners, or other chemical solvents in case of damage or distortion.
    WARNING: Before cleaning or conducting maintenance, please turn off and unplug the machine to avoid the risk of electrocution

  2. Filter Cleaning
    ● Pull to open the dehumidifier’s back panel, and slide the filter upward to take it out from the panel.
    ● Use a vacuum cleaner to gently absorb the dust on the filter’s surface.
    ● If the filter is dirty, wash it with water and a soft detergent, and dry it thoroughly afterwards.
    ● Put the filter back in the back panel, and close the dehumidifier’s back panel.

HURRIKAN OL50 D056CW Commercial Dehumidifier - Body
Cleaning

WARNING: It is strongly advised to rinse the filter every two weeks. Any dust blocking the filter will potentially affect the machine’s functionality.

5.2. LOCATION

  1. Place the appliance on a firm and horizontal surface.
  2. Never install the appliance at a place that could be subject to:
    ● Heat sources such as radiators, heat registers, stoves or other products that produce heat.
    ● Possible splashing of oil or water
    ● Direct sunlight
    ● Mechanical vibration or shock
    ● Excessive dust
    ● Lack of ventilation, such as cabinet or bookcase
    ● Uneven surface

TROUBLE SHOOTING

  1. Functioning Temperature: 41°F ≤ Ambient Temperature ≤ 95°F
    When the ambient temp is lower or higher than the functioning temp, the dehumidifier stops functioning.
    When 41°F ≤ Ambient temperature ≤ 61°F, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running.

  2. Before Calling for Service
    Before contacting the customer service, please review the following troubleshooting list that includes common problems that are not the result of a defect in workmanship or materials.

Trouble Cause Solution
Not operating Unit is not plugged in. Plug in the unit.
Room temperature is under 41°F or above 95°F. To protect the machine, use it

only when ambient temperature is between 41°F and 95°F.
The humidity sensor is loose or defective; the screen will show”5″.| Check the sensor connection. Use a blower to dry the humidity sensor behind the front shell. If the machine still does not run, contact your retailer to replace the sensor.
If the temperature sensor is loose or defective; the screen will showt61:| Check the sensor connection. Contact your retailer to replace the sensor.
Humidity level not dropping| When the humidity set point is 2% higher than the ambient humidity level.| Reset the humidity to a lower set point, or power the machine off if the ambient humidity level already satisfies you.
Reduced dehumidifying capacity| Filter jammed.| Clean the filter as instructed.
Air-in and/or Air-out louvers jammed.| Clear the blockage from Air-in and/or Air-out louvers.
No air inlet| Filter or air-in louver jammed.| Clean the filter as instructed or clean the louver blockage.
Loud noise| Machine tilted.| Move it to a flat ground.
Filter jammed.| Clean the filter as instructed.
Error Code ‘El’| Temperature sensor problem| Change the sensor
Error Code ‘E2’| Humidity sensor problem| Change the sensor
Error Code ‘CL’| When the ambient temperature drops below 41°F, this error code will appear, and the compressor and fan will shut down.
Error Code ‘CH’| When the ambient temperature is above 95°F, this error code will appear, and the compressor and fan will shut down.
Error Code ‘LO’| When the ambient humidity drops below 20%, this error code will appear, and the compressor and fan will shut down.
Error Code ‘HI’| When the ambient humidity is above 95%, this error code will appear, but the compressor and fan will keep operating.
Error Code ‘E4’| Water is full or the pump is malfunctioning.| Drain out water or contact customer service for repairment.

WARNING:
If the Water Full indicator is always on, there may be a malfunction in the machine. Please seek technical support from professionals.
If anything unexpected happens, please turn off and unplug the machine immediately, and seek technical support from certified electrical engineers.

STORAGE & DISPOSAL

7.1. STORAGE
If you are not going to use the appliance for an extended period of time (more than a few weeks), it is best to clean and dry it completely before preserving the appliance in a ventilating, dry, corrosive gas-free, and safe indoor space.
The appliance must be kept in an upright position when in storage.

Note: Manual drainage can help with completely drying the appliance.

7.2. DISPOSAL
Do not dispose of electrical appliances as unsorted municipal waste. Instead, use designated collection facilities.
Contact your local government for information regarding the available disposal collection system.

WARRANTY

8.1. WARRANTY BRAND CARDHURRIKAN OL50 D056CW Commercial Dehumidifier -
WARRANTY BRAND CARD

HURRIKAN logo
Protection To Fix Card

We certify the authenticity of this item and confirm that it has been subjected to the most exacting quality control. Its high quality is a symbol of the fine reputation of this trademark.
One-year warranty offered by Hurrikan will be in effect automatically since the date of delivery.
If you want to extend the warranty to two years or have any other concerns, please don’t hesitate to contact us through email at support@hurrikan.us.

8.2. HURRIKAN ONE-YEAR LIMITED WARRANTY POLICY SUMMARY
Each Hurrikan product is covered with a 1-year warranty, starting from the date of delivery. Under this limited warranty, Hurrikan warrants that each Hurrikan product you purchase will be free from any material and workmanship defects under normal use, and products experiencing this type of defects are guaranteed free repairment during the warranty period. Such warranty provision is in addition to rights provided under local consumer laws. Products malfunctioning due to non-manufacturing damage or improper usage are not covered under this warranty, and will face service fee for repairment. Repairment service options are dependent on the country from which the service is requested, and may be restricted to the original country of purchase. International shipping fee might apply, depending on the location.
To obtain the warranted repairment, please fill out this warranty card and contact support@hurrikan.us with a photo/scanned version of the card. You might be required to provide more purchase details, depending on the case. If you wish to extend the warranty or express any questions or concerns, please also email support@hurrikan.us.

8.3. WARRANTY CARD

Product Name Hurrikan Dehumidifier Model No. OL50-D056CW
Purchase Site Date of Purchase
Customer Name Address
Tel. No. Email
Invoice No. Warranty Period 1 year

COMMERCIAL DEHUMIDIFIER

HURRIKAN OL50 D056CW Commercial Dehumidifier - Symbol
1
Please read this manual before operating and save it for future reference. Every dehumidifier is covered with a 1-year free warranty offered by Hurrikan that is automatically valid from the date of purchase. To extend the warranty or express any questions or concerns, please email us at support@hurrikan.us

HURRIKAN logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals