Hotpoint AH12H09D3B PTAC Heat Pump Unit with Electric Heat Backup 20 amps User Manual
- May 15, 2024
- Hotpoint
Table of Contents
Hotpoint AH12H09D3B PTAC Heat Pump Unit with Electric Heat Backup 20 amps
Specifications
- Model: AH12H09D3B
- Heater Voltage: 230/208 Volts
- Heater Watts: 3,500 / 2,897
- Heater BTU: 10,900 / 8,900
- Heater Amps: 15.3 / 13.7
- Heat Pump Watts: 720 / 690
- Heat Pump BTU: 8,400 / 8,200
- COP: 3.4
Installation Information
Wall Case Dimensions
- MAXIMUM CORD EXTENSION: 30 inches
- A: 70 inches
- C: 42-1/4 inches
Wall Opening Dimensions
- Add 1/4 to A and C dimensions for all cut-outs.
- RAB80 16-1/4 Min. H x 42-1/4 Min. W
Electrical Information
- Min Circuit: 20 amps
- Recommended protective Device: 20 amp time-delay fuse or breaker
- Features and Benefits: 2 31-5000809 Rev. 0
Frequently Asked Questions (FAQ):
Q: How do I clean the filters on the AH12H09D3B?
- A: To clean the filters, follow these steps
- Turn off the unit and unplug it from the power source.
- Remove the front panel to access the filters.
- Vacuum or wash the filters with mild soap and water.
- Allow the filters to dry completely before reinstalling them.
Q: What maintenance tasks should I perform regularly on the AH12H09D3B?
- A: Regular maintenance tasks include.
- Cleaning or replacing the filters every few months.
- Checking for any obstructions in the airflow.
- Inspecting the unit for any signs of damage or wear.
- Ensuring proper electrical connections and safety measures are in place.
AH12H09D3B
- Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 20 amps, 230/208 Volt DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
- All wiring, including installation of receptacles, must be made under local electrical codes and regulations.
- NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.
GRILLE OPTIONS
- Stamped Aluminum Grille – RAG70
ELECTRICAL CONNECTION
- 230/208-volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
- The power cord is permanently attached to all Hotpoint chassis.
WALL CASE DIMENSIONS
- RAB80 WALL SLEEVE
- Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
- WALL OPENING DIMENSIONS
- Add 1/4” to A and C dimensions for all cut-outs.
- RAB80 16-1/4” Min. H x 42-1/4” Min. W
AH12 ELECTRIC HEATER
230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 720 / 690
Heat Pump BTU| 8,400 / 8,200
COP| 3.4
FEATURE AND BENEFITS
- 9,500 / 9,500 cooling BTU
- 11.4 EER
- 8,400 / 8,200 heating BTU
- 3.4 COP
- R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
- 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
- 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
- Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
- Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
- Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
- Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
- Auto Power Recovery – In case of power failures, units automatically resume their operation when power is restored, reducing maintenance calls
- Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
- Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand