SIQURA SA3-FIX Series TKH Security Sa Fix
Important Information
Note: To ensure proper operation, please read this manual thoroughly before using the product and retain the information for future reference.
Nothing from this publication may be copied, translated, reproduced, and/or published by means of printing, photocopying, or by any other means without the prior written permission of TKH Security.
TKH Security reserves the right to modify specifications stated in this manual.
Brand names
Any brand names mentioned in this manual are registered trademarks of their
respective owners.
Liability
TKH Security accepts no liability for claims from third parties arising from
improper use other than that stated in this manual.
Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant product components, this manual may nonetheless contain errors and inaccuracies. We invite you to offer your suggestions and comments by email via info@tkhsecurity.com. Your feedback will help us to further improve our documentation.
How to contact us
If you have any comments or queries concerning any aspect related to the
product, do not hesitate to contact:
TKH Security B.V.
Werner von Siemensstraat 7
2712 PN Zoetermeer
The Netherlands
Introduction
Preserve this manual as a reference for future needs.
| Used electrical, electronic and stainless steel products should not be
mixed with general waste. For proper treatment, recovery and
recycling of old products, take them to applicable collection points, in
accordance with your national legislation and the Directives 2011/65/EU and
2012/19/EU.By disposing of these products correctly, you help to save valuable
resources and prevent any potential negative effects on human health and the
environment which could otherwise arise from inappropriate waste handling. For
more information about collection and recycling of old products, contact your
local municipality or your waste disposal service. Penalties may be applicable
for incorrect disposal of this waste, in accordance with national legislation.
---|---
The manufacturer declines all liability for any consequence resulting from improper installation practices, tampering or improper uses of the product.
The descriptions and illustrations contained in this manual are not binding. The manufacturer reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication.
The manufacturer declines all responsibility for any consequences resulting from improper use of the product, or use which is different from that expected and specified in the present documents.
General information
Description
The SA3-FIX series are AISI 316L Stainless Steel camera housings specifically designed for Hazardous Area applications.
The SA3-FIX can be assembled the latest generation zoom module day/night and/or thermal imaging modules (TX3).
Note: This product should installed by suitably trained personnel
These instructions are intended for their sole use.
Models
This manual contains instructions on installation and use of the SA3-FIX series. It covers the following models:
- SA3-FIX(v). Fixed camera station
- SA3-FIX(v)W. Fixed camera station with wiper
- SA3-FIX(v)T. Fixed thermal camera station
- SA3-FIX(v)-IR34. IR-LED illuminator
(v) determines the power supply voltage. (v) can be 24 for AC 24 V, 120 for AC 120 V or 230 for AC 230 V
Symbols used
WARNING
It indicates a potentially dangerous situation that, if ignored, could lead to
physical or mortal injuries and/or damage to the unit. Read the provided
instructions carefully.
ELECTRICAL HAZARD
It indicates a potentially dangerous situation involving electricity risks
that could lead to physical or mortal injuries and/or damage to the unit. Read
the provided instructions carefully.
OPTICAL RADIATION
It indicates a potentially dangerous situation due to the emission of visible
light or infrared that could be harmful for eyes. Read the provided
instructions carefully.
Before you continue
| Prior to installation and operation, carefully read all instructions in this
manual and heed all warnings.
---|---
Use the original packaging to transport the unit. Disconnect power supply
before moving it. In case of returning the equipment, the original packaging
must be used.
Any change performed on the unit that is not previously approved by the
manufacturer will void its warranty.
Trying to manually force the wiper will result in damaging the device and will
void the warranty
| When leaving the unit unused for long periods, disconnect supply cables
For security reasons, do not install the unit in the proximity of water
containers and never push objects or pour liquids into the unit. The unit can
be safely used in damp environments or outdoors, as long as the glands are
properly sealed.
The internal transformer of the unit should never be used to power external
devices.
Connecting GND/Earth/PE to line or neutral will result in damaging the device
and will void the warranty.
No ventilation is needed for the unit, as it is completely sealed.
Only for SA3-FIX IR34 IR LED illuminator:
| The unit emits high intensity IR light. Wear protective eyewear. Avoid
direct eye and skin exposure. Please follow safety precautions given in IEC
60825-1 and IEC 62471.
---|---
Technical Data
General & Mechanical
General & Mechanical
Construction:| AISI316L Stainless Steel
Finishing:| Electro-polished
Electrical
Heater:| T[°C] ON=12±4°C, T[°C] OFF=20±3°C (thermostatically controlled)
Power consumption:
SA3-FIX(v)| 40W MAX
SA3-FIX(v)W| 40W MAX
SA3-FIX(v)T| 40W MAX
SA3-FIX(v)-IR34| 25W MAX
Supply voltage:
(v)= 24| AC 24V (±10%)
(v)= 120| AC 120V (±10%)
(v)= 230| AC 230V (±10%)
Certifications
Weatherproof standard:| IP66/IP67/IP68/IP69, NEMA-4X
EMC, LVD| CE compliant
Unpacking
Contents in the box
The camera comes in a sturdy carton box with the following contents::
- Fixed camera station
- Hard copy of this manual
- Camera fixing kit
- Sunshield (Except for the SA3-FIX-IR)
- Washing nozzle brackets kit (for wiper versions only)
Unpack
If the package or the contents appears to be damaged, notify the shipper
immediately.
Check that all parts listed above are included.
Installation
Before you begin
| Proper stainless steel tools should be carefully chosen and used during
installation and to fasten the unit to the surfaces, in accordance with the
local requirements.
---|---
Make sure that the installation surface can support at least four times the
weight of the unit in normal operating conditions. Where the equipment may be
exposed to excessive external stresses (e.g., vibration, heat, impact), then
the equipment must be protected by additional means of protection. Additional
protection may be required if the equipment is to be installed in locations
where it may be subject to damage.
It is not advised to use automatic tools (such as drill drivers) for
tightening/loosening the screws, it may result in damaged threads.
Use caution when lifting and (dis)assembling the unit. It is recommended that
non-slip protective gloves be worn during installation. The unit could bear
sharp edges
Electrical connections (such as plugs and cords) must be protected from
potential hazardous environmental factors (e.g., foot traffic, hitting
objects).
Make sure that the unit case is properly earthed, connecting all the earth
ground studs.
An all-pole mains switch with an opening distance between the contacts at
least 3 mm (1/8’’) in each pole must be incorporated in the electrical
installation. The switch must be equipped with protection against the fault
current towards the ground (differential) and the overcurrent (magnetothermal,
maximum 15 A). It must be very quickly recognizable and readily accessible
| Recommended fuse for AC 115 V / 230 V: 2 A Delayed Fuse T (Time delay) or
equivalent resettable devices. Recommended fuse for AC 24 V: 4 A Delayed Fuse
T (Time delay) or equivalent resettable devices.
For connection to the main power supply use suitably insulated multipolar
cable having minimum 3×1,5 mm2. The yellow/green PE wire must be longer than
the others.
Connecting GND/Earth/PE to line or neutral will result in damaging the device
and will void the warranty.
Do not connect the unit to a supply circuit unless the installation is
completed. Check before assembling the position of the O-ring seals in their
groove.
Mounting the camera
Mounting pattern
The screws must be tightened with suitable torque by authorized and qualified
personnel only, by using a suitable torque wrench tool
Wall-mount (SA-FIX WM01)
To mount the SA3-FIX camera to a horizontal wall an SA-FIX WM01 must be used.
Choose the proper fasteners for surface. The screws must be tightened with
suitable torque by authorized and qualified personnel only. See appendix for
drawings of the camera’s physical dimensions.
Pole mount (SA-FIX PM01 + SA-FIX WM01)
Use SA-FIX PM01 adapter to fit the SA3 camera to a pole. It is suited poles
with diameter ranging from min 80mm to max 115 mm.
Assemble the SA-FIX WM01 with one of the SA-FIX PM01 shells using 4x screws
(1), 4x plane washers (2), provided with the PM01 kit. Check that all the
threads are clean. When fixing the screws use thread locking compound (e.g.,
Loctite) and allow an appropriate rest period.
Pole top mount (SA-FIX PTM01
Use SA-FIX PTM01 swivel to mount the SA3-FIX camera on the top of a pole or flat surface.
Fix the mounting plate on the top of the pole using the provided 4x M8 screws
(1), 4x M8 plane washers (2) and 4x M8 nuts (3). Check that all the threads
are clean. When fixing the screws use thread locking compound (e.g., Loctite)
and allow an appropriate rest period.
For other surfaces choose the proper fasteners to mount the SA-FIX PTM01
Mounting the camera on the SA-FIX PTM01 and SA-FIX WM01
Fix the unit to the swivel joint (1) using the 2x screws (2) and 2x washers
(3) provided with the camera station. For the best stability reduce the unit’s
overhang. The plate (4) on the lower rail allows to adjust horizontal position
(forth/back) of the housing
| Any action performed on the unit which is not described in this manual may
damage the camera.
---|---
Check the supply voltage marked on the label. Incorrect power supply voltage
may damage the unit. Do not overload the terminal connection, as it may cause
fire or electrical shock hazard.
Make sure that the power is disconnected. An accessible mains switch must be
installed to switch-off the power. Wait at least 5 min before opening the
camera
| An all-pole mains switch with an opening distance between the contacts at
least 3 mm (1/8’’) in each pole must be incorporated in the electrical
installation. The switch must be equipped with protection against the fault
current towards the ground (differential) and the overcurrent (magnetothermal,
maximum 15 A). It must be very quickly recognizable and readily accessible
The internal grounding terminal shall be used for protective earth connection.
The external terminal is only for a supplementary bonding connection where
local codes or authorities permit or require such connection.
Installation of composite cable (INT3 -SA20/25)
The armored composite cables from TKH Security are pre-fitted with cable glands on each side for ease of installation. The following tails are available:
- INT3-RJ5 SA20, 5 meter composite cable for Fast ethernet, M25 and M20 adapter
- INT3-RJ10 SA20, 10 meter composite cable for Fast ethernet, M25 and M20 adapter
- INT3-SM5 SA20, 5 meter composite cable with SM fiber, M25 and M20 adapter
- INT3-SM10 SA20, 10 meter composite cable with SM fiber, M25 and M20 adapter
If the composite cable tail isn’t provided by TKH Security, please check the correct cable gland thread dimension. (M20 x1.5) To maintain the IP rating of the unit, use only cables, cable glands, blind-stops, adapters that are suitably rated.
Plastic caps are used to close cable entries during shipment, remove them and close off any unused cable entry with an appropriate blind-stop.
SA3-FIX wiring
ID | Name | Notes |
---|---|---|
M1 | Input supply voltage | Depending on model. Please refer to marking plate |
supply voltage information
M2| Camera supply voltage| DC 12 V, 2 A max.
F1| Fuse| AC 24 V model: 4 A, HT, AC 250 V, 5×20 AC 120/240 V models: 3.15 A,
HT, AC 250 V, 5×20
SA3-FIX W wiring
ID | Name | Notes |
---|---|---|
M1 | Input supply voltage | Depending on model. Please refer to marking plate |
supply voltage information
M2| Camera supply voltage| DC 12 V, 1 A max.
M3| Wiper/Washer Control output| Pin 1-2 Wiper output. Connected by TKH
Security.
Pin 3-4 Washer output. AC 24 V Washer control.
M4| Reserved|
M5| RS485| Optional Pelco D (2400 Baud)
Pin 1: A (TX+)
Pin 2: B (TX-)
Pin 3: RS485 GND
M6| Wiper/Washer Input| Closing Pin1 to Pin3 for at least 0,5 seconds
activates Wiper for 10 seconds.
Closing Pin 2 to Pin3 for at least 0,5 seconds activates Washer for 5 seconds.
F1| Fuse| AC 24 V model: 4 A, HT, AC 250 V, 5×20
AC 120/240 V models: 3.15 A, HT, AC 250 V, 5×20
The RX24IO board installed inside the camera station is equipped with three LEDs.
- The DL1 LED (green) is ON when the board is correctly powered.
- The DL2 LED (red) blinks when the firmware is working.
- The DL3 LED (green) blinks when a command is received from the RS485 bus.
The 8-way DIP switch on the telemetry receiver (DIS1) can be used to set up
the unit address (binary). When a switch is on the ON position, the relative
digit has value 1, otherwise the value is 0. For example, the address 13
(00001101 in binary) can be set up turning ON the switch 1, 3 and 4 (see
figure).
Factory reserved presets in Pelco D:
- Calling preset 87 activates auxiliary output AUX3 (wash wiper cycle). Auto off after 30 seconds.
- Calling preset 88 activates auxiliary output AUX1 (wiper). Auto off after 10 seconds.
- Calling preset 89 activates auxiliary output AUX2 (washer). Auto off after 5 seconds.
The unit has 8 auxiliary functions, as described below:
- Aux1 is used for Wiper activation only (this function will activate the wiper for approx. 10 seconds).
- Aux2 is used for Washer pump activation only (this function will activate the washer pump for approx. 5 seconds).
- Aux3 is used for Wash-Wiper STOPPABLE automatic cycle (this function will activate the wash-wiper cycle approx. 30 seconds). Whenever a command is issued, the cycle will be interrupted.
- Aux4 is used for Wash-Wiper UNSTOPPABLE automatic cycle (this function will activate the wash-wiper cycle approx. 30 seconds). During the Wash-Wiper cycle, any command issued is ignored.
SA3-FIX-IR34 wiring
ID | Name | Notes |
---|---|---|
M1 | Input supply |
voltage
| Depending on model. Please refer to marking plate supply voltage
information
M2| Photocell| Pin 1-2: Reserved.
Pin 3-4: External sensor
M3| Day/Night I/O| Pin 1-2: Output D/N signal (night=ON, day=OFF).
Pin 3-4: Reserved
M5| DC output| Auxiliary DC 12V out (Pin 1= V+; Pin 2= V-)
M6| IR Input| Dry contact/Open collector (NPN) input for IR LEDs activation
(Example: external camera output)
S1| Test| Manual IR LEDs activation test .
TR3| Sensitivity| Adjust the sensitivity of the light sensor photocell.
Counterclockwise rotation decreases sensitivity.
Setting it to 0 disables the activation from light sensor photocell.
DL1| Green LED| is ON when the board is correctly powered
DL2| Yellow LED| is ON when the IR LEDs are interrupted (open-led)
DL3| Red LED| is ON when the IR LEDs are not activated or when they are in
short-circuit
DL4| Yellow LED| is ON when the IR LEDs are in the activation phase during its
hysteresis delay
F1| Fuse| 1 A, F, AC 250 V, 5×20
Closing camera house
Slide the camera housing body (1) to close the unit.
WARNING: for SA3-FIX W cameras, slide the body (1) near the flange as per below image. Before closing the unit, set the wiper in its original previous position.
Fix the body using the 4x screws (2), the washer (3) and the screw (4).
Installing the washer nozzle on the EX3 FIX W
Fix the nozzle bracket (1) on the camera station with the provided screw (2).
Adjust horizontal position of the nozzle, use the screwdriver slot on the
nozzle to adjust the tilt position.
Maintain the unit
Inspections
This equipment has been designed to fit in harsh environments requiring little or no maintenance. Suggested inspection interval is six months, but extremely harsh environments may require more frequent inspection and maintenance checks. On each inspection, check the O-ring seals and the window wiper blade integrity. Replace them when necessary.
Routine activities
Regularly perform the following routine activities:
-
Clean the glass
Use water or a liquid detergent that will not generate a hazardous situation. -
Clean the germanium window
Use water or a damp cloth. Be careful not to scratch the carbon coating. Do not use ethyl alcohol, solvents, hydrogenated hydrocarbons, strong acids or alkalis. This will irreparably damage the germanium window. -
Clean the unit
Use a dry or damp cloth. Do not use compressed air to clean the unit. -
Check electrical connections
Check cables and electrical connections for integrity and tightness. Replace worn cable(s) or tighten loose connections. -
Check mounting accessories
Check mounting bolts and screws for integrity and tightness. Replace or tighten any damaged/loose mounting hardware.
Suitable precautions: regular checks as part of routine inspections or establishing from the material’s datasheet that it is resistant to specific chemicals.
Fuse replacement
If necessary, replace the fuse (F1) as indicated in sections “SA3-FIX wiring”,
“SA3-FIX W wiring”, or “SA3-FIX-IR34 wiring”.
Sync IR with D/N mode
-
. Open the web interface; click on the “System” tab and open [Events] > [Application]. Check the boxes as shown below:
-
Click the [Manual Trigger] page and again take over the settings as shown in screenshot below
-
Click to the [Scheduling] page and take over the following settings:
With these settings the Alarm contact output is synchronized with the Day/Night mode of the camera. The Alarm output of the optical camera must be connected to M6 of the IR control board to switch on/off the IR illuminator
EU Certificates
EU Declaration of conformity
Appendix: Technical drawings
SA3-FIX dimensions (mm)
SA3-FIX W dimensions (mm)
SA3-FIX T dimensions (mm)
SA3-FIX IR dimensions (mm)
CUSTOMER SUPPORT
tkhsecurity.com
TKH Security | Siqura SA3 FIX Series | Installation manual v1 29-30
Our Brands
© 2020, TKH Security.
http://tkhsecurity.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>