Product Specifications

  • Models: FNL18L103B, FN24L103B, FN30L103B
  • For Use With Chassis: FNV18C-1, FNV24C-1, FNV30C-1
  • Compliance: ANSI Z21.11.2 (Unvented Heaters), ANSI Z21.60 (Decorative Vented Appliances)

Product Usage Instructions

Safety

Before installation or use, ensure compliance with local codes and regulations regarding vented gas log sets.

Qualified Installing Agency

Only a qualified installation agency should install the log set to ensure proper setup and safety.

Installation Guidelines

Proper log placement is essential for burner performance. Refer to the manual for correct positioning. Malformed or broken logs should be replaced promptly.

Proper Log Set Operation

If soot appears on a log, cease operation and seek service. Well-maintained log sets should not deposit soot.

Wood Burning Fireplaces

Clean the firebox and chimney of creosote before installing the gas log set to prevent odors and sooting.

Installing Logs

Model FNL18L103B

  1. Place vermiculite into the burner pan and spread glowing ember uniformly on top.
  2. Install grate steps as shown in Figure 1.
  3. Position log #1 on the grate steps.
  4. Place log #2 on the left front of the grate base and log #3 on the right front.

INSTALLATION

Qualified Installation Agency
This set should only be installed by a qualified installation agency.

Proper Log Placement
Log placement is critical to proper burner performance. Logs must be correctly positioned into the burner. The illustrations in this manual show the proper position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs. Logs must fit firmly onto the burner when positioned as shown in the illustrations. Malformed logs or broken logs must be replaced.

Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.

Wood Burning Fireplaces
The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the log set causing odors and possibly sooting.

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Install the Grate Steps as shown below on the right and left side grate fingers at the back of the rear legs. Use the provided screws to attacher the inner and outer step together. This process is the same for all models.

DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-
fig-1

MODEL FNL18L103B

DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-
fig-2

  1. Place vermiculite into burner pan. Pull glowing ember loosely, and sprinkle uniformly on the surface of vermiculite as shown below.
  2. Install grate steps (see Figure 1).
  3. Place log #1 on the grate steps.
  4. Place log #2 on the left, front of the grate base.
  5. Place log #3 on the right, front of the grate base.
  6. Place log #4 on log #1 and log #2.
  7. Place log #5 on log #1 and log #2.
  8. Place log #6 on log #1 and log #3.
  9. Place log #7 on log #5 and log #3.
  10. Place log #8 on log #4 and log #5.

MODEL FNL24L103B

DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-
fig-4

  1. Place vermiculite into burner pan. Pull glowing ember loosely, and sprinkle uniformly on the surface of vermiculite as shown below.
  2. Install grate steps (see Figure 8, page 10).
  3. Place log #1 on the grate steps.
  4. Place log #2 on the left, front of the grate base.
  5. Place log #3 on the right, front of the grate
  6. Place log #4 on log #1 and log #3.
  7. Place log #5 on log #1 and log #2.
  8. Place log #6 on log #1 and log #2. Log #6 Log #5DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-fig-3

MODEL FNL30L103B

  1. Place vermiculite into burner pan. Pull glowing ember loosely, and sprinkle uniformly on the surface of vermiculite as shown below.
  2. Install grate steps (see Figure 8, page 10).
  3. Place log #1 on the grate steps.
  4. Place log #2 on the left, front of the grate base.
  5. Place log #3 on the right, front of the grate
  6. Place log #4 on log #1 and log #2.
  7. Place log #5 on log #1 and log #2.
  8. Place log #6 on log #5 and log #3.
  9. Place log #7 on log #1 and log #3.
  10. Place log #8 on log #1 and log #3.
  11. Place log #9 on log #4 and log #5.
  12. Place log #10 on log #7 and log #8 Log #9 Log #10

DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-
fig-5

CURING LOGS

During the 2-3 hour appliance curing period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.

To ensure proper curing of the logs:

  • Ignite a 2″ flame and maintain it for 1 hour.
  • Burn the logs in consecutive 1 hour periods raising the flame an additional 2″ to full flame height for a total of three hours.

This list contains replaceable parts used in your heater. When ordering parts, contact authorized dealers of this product or call customer service at 1-855-607-6557. When calling have your model and serial numbers available.

DuluthForge-FNL18L103B-Vented-Natural-Gas-Log-Cluster-
fig-6

Frequently Asked Questions (FAQ)

Q: What should I do if I notice soot on a log?

A: Cease operation of the log set immediately and contact customer service for assistance.

Q: Can I install the log set myself?

A: It is recommended to have a qualified installation agency handle the installation to ensure proper setup and safety.

References