SONBEST SC7237B Interface LED Display Differential Pressure Controller User Manual
- May 15, 2024
- SONBEST
Table of Contents
SC7237B
RS485 interface LED display differential pressure controller
User Manual
File Version: V23.8.2
SC7237B using the standard RS485 bus MODBUS-RTU protocol,easy access to PLC DCS and other instruments or systems for monitoring state quantities. The internal use of high-precision sensing core and related devices to ensure high reliability and excellent long-term stability,can be customized RS232,RS485,CAN,4-20mA,DC0~5V\10V,ZIGBEE,Lora,WIFI,GPRS and other output methods.
Technical Parameters
Technical parameter | Parameter value |
---|---|
Brand | SONBEST |
Measuring media | Non-corrosive gases |
Gauge pressure measurement range | -100~0~100KPa |
Differential Pressure Measurement Range | 0~0.2~100KPa |
Differential Pressure Measurement Accuracy | ±0.5%FS |
Communication Interface | RS485 |
Default baud rate | 9600 8 n 1 |
Power | AC185~265V 1A |
Running temperature | -30~85℃ |
Working humidity | 5%RH~90%RH |
Product Size
Key details, quick start
STANDARD MDDBUS-RTU PROTOCOL, THE DEFAULT BAUD RATE IS 9600, IN VALID, 8-BIT DATA BITS, SOFTWARE CAN CHANGE THE THRESHOLD AND OTHER PARAMETERS, THROUGH RS485 CAN QUERY REAL-TIME ILLUMINATION DATA.
| : Use the select key when setting
---|---
| :Up Key
| : Down Key
SET| : Set Key
Page 4 sets the alarm
mode 1: Over-limit Alarm
Mode 2: under-limit alarm
mode 3: over/under-limit action
Illumination display value X1000 = current value as shown in figure 3.63, indicating the current illumination value of 3630 lux
- Press SET to enter upper limit threshold settings press” ” to select the position, press” “” V” to adjust the value mode 1,3, when the value is greater than the upper limit threshold relay 1 action upper limit threshold: the default value of 50000, the maximum value of 65000
- Press SET twice to enter the lower limit threshold settings press” ” to select the position, press” ” !” ” to adjust the numerical value mode 2,3, when the value is less than the lower limit threshold relay 2 action lower limit threshold: default 0, maximum 65000
- Press SET three times to enter the control return settings press” ” to select the position, press” ” “! ” ” ” to adjust the value of the default return difference 1000, the maximum 60000
- Press four sets to enter the control mode, press” ” to select the position, press”! “”” to adjust the numerical value rnode 1, above the upper threshold action mode 2, below the lower threshold action mode 3, above the upper threshold action/below the lower threshold action
Wiring instructions
In the case of broken wires, wire the wires as shown in the figure. If the
product itself has no leads, the core color is for reference.
How to use software?
Flower farming
Flowerfarming requires light management According to the light requirements of
plants
To cooperate with the sensor to control the illumination
GREEN HOUSE
Effective management with sensors Create a good light environment for crops
Promote better photosynthesis
Construction
Adevice for measuring levels of light intensity
Under certain circumstances
Strict illumination requirements are required
Product List
RS485 interface LED displa differential pressure controller
Certificate
Communication Protocol
The product uses RS485 MODBUS-RTU standard protocol format, all operation or
reply commands are hexadecimal data. The default device address is 1 when the
device leaves the factory, and the module or NON-Recorder default baud rate is
9600,8,n,1 ,but data recorder default baud rate is 115200 .
- Read data (function code 0x03)
Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 01 84 0A.Address| Function Code| Start Address| Data Length| Check Code
---|---|---|---|---
1| 3| 00 00| 00 01| 84 0A
For the correct query frame, the device will respond with data: 01 03 02 00 79 79 A6 , response format:
Address | Function Code | Length | Data 1 | Check Code |
---|---|---|---|---|
1 | 3 | 2 | 00 79 | 79 A6 |
Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
- Common data address table
For example, if the current state is too small, we want to add 1 to its real value, and add 100 to the
current value. The correction operation command is: 01 06 00 6B 00 64 F9 FD .Device Address| Function Code| Register Address| Target Address| Check Code
---|---|---|---|---
1| 6| 00 6B| 00 64| F9 FD
After the operation is successful, the device will return the information: 01
06 00 6B 00 64 F9 FD , after the successful change, the parameters will take
effect immediately.
Disclaimer
This document provides all information about the product, does not grant any
license to intellectual property, does not express or imply, and prohibits any
other means of granting any intellectual property rights, such as the
statement of sales terms and conditions of this product, other issues. No
liability is assumed. Furthermore, our company makes no warranties, express or
implied, regarding the sale and use of this product, including the suitability
for the specific use of the product, the marketability or the infringement
liability for any patent, copyright or other intellectual property rights,
etc. Product specifications and product descriptions may be modified at any
time without notice.
Contact Us
Company: Shanghai Sonbest Industrial Co., Ltd
Address:Building 8,No.215 North east road,Baoshan District,Shanghai,China
Web: http://www.sonbest.com
Web: http://www.sonbus.com
SKYPE: soobuu
Email: sale@sonbest.com
Tel: 86-021-51083595 / 66862055 / 66862075 / 66861077
Sha nghai Sonbest Industrial Co., Ltd
References
- Home-上海æœåšå®žä¸šæœ‰é™å…¬å¸
- Home-SONBEST -SONBUS.COM| THE SENSOR COMPANY
- Home-SONBEST -SONBUS.COM| THE SENSOR COMPANY
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>