FUTURECOM TT4079A Portable Digital Repeater User Guide
- May 15, 2024
- FUTURECOM
Table of Contents
FUTURECOM TT4079A Portable Digital Repeater
Ordering Instructions
Ordering Instructions – PLEASE READ CAREFULLY
If only ordering spares or accessories, proceed to step 5. If only ordering services, proceed to section 6.
- Select PDR8000® Rackmount Frequency type (Section 1). NOTE: PDR8000® Frequency type model provides a repeater designed to fit into a standard 19” rack. includes Display with local Channel Change. User must supply their own 12VDC Power Supply.
- Select optional features if applicable to your intended operation (Section 2).
- For full duplex operation, select the appropriate duplexer option (Section 3). NOTE the frequency requirements can be found in Section 3 to ensure your frequency plan meets the operating requirements. Duplexer is not mandatory and the ‘No Duplexer’ option can be chosen when full duplex capability is not desired.
- Select optional 50- Watt Booster Power Amplifier for PDR8000® RACKMOUNT (section 4)
- Select Options and Spares (Section 5).
- Select optional services as required (section 6).
Important Notes
- Only the frequency bands shown in Section 3 are available as standard configurations. For custom filtering, please contact Futurecom: Futurecom.Sales@motorolasolutions.com 1 Transmit and 1 Receive frequency are required for ordering. Units will be factory-tuned to these frequencies, so accuracy is important.
- Standard PDR8000® delivery time is 10-12 weeks from the time the order is placed and the frequency information is provided. Frequency information must be accurate and follow the frequency plan requirements described in this document to avoid delays.
- Duplexer is not mandatory and the ‘No Duplexer’ option can be chosen when full duplex capability is not desired.
- PDR8000® Rackmount models require users to supply their own 12VDC Power Supply.
- For all sales inquiries, please contact Futurecom sales at Futurecom.Sales@motorolasolutions.com.
- All pricing for the PDR8000® can be found in Motorola P-CAT.
- Programming software is available for download at http://futurecom.com/support.
- Subscribe to our newsletter if you want to be informed about new releases and updates. Please visit http://futurecom.com/support/newsletter/.
Frequency plans that do not meet Futurecom’s specified frequency separation are custom orders. Please contact Futurecom to determine if a custom frequency plan is viable and for quotations on viable plans. Futurecom.Sales@motorolasolutions.com. Futurecom, DVR-LX, PDR8000, the Futurecom Logo and the Stylized FC logo are registered trademarks of Futurecom Systems Group, ULC. All other trademarks are the property of their respective owner. © 2022 Futurecom Systems Group, ULC. All rights reserved.
Rackmount Frequency
- PDR8000® Rackmount Frequency Type
- PDR8000® 136-174 MHz**
ORDER CODE| ITEM| INCLUDES| PREREQUISITES| NOTES
---|---|---|---|---
TT4079A| Base Order Code PDR8000 ® – VHF RACKMOUNT| VHF repeater designed to fit into a standard 19” rack includes Display with local Channel Change.| | Wireline Connections; see section 2 for wireline connections options User must supply their own 12VDC Power Supply.** - PDR8000® 380-430 MHz**
ORDER CODE| ITEM| INCLUDES| PREREQUISITES| NOTES
---|---|---|---|---
TT4080A| Base Order Code PDR8000 ® – UHF 380-430 MHz RACKMOUNT| UHF 380-430 MHz designed to fit into a standard 19” rack includes a Display with local Channel Change.| | Wireline Connections; see section 2 for wireline connection options User must supply their own 12VDC Power Supply.** - PDR8000® 450-470 MHz**
ORDER CODE| ITEM| INCLUDES| PREREQUISITES| NOTES
---|---|---|---|---
TT4081A| Base Order Code PDR8000 ® – UHF 450-470 MHz RACKMOUNT| UHF 450-470 MHz designed to fit into a standard 19” rack includes Display with local Channel Change.| | Wireline Connections; see section 2 for wireline connection options User must supply their own 12VDC Power Supply.**
- PDR8000® 136-174 MHz**
Optional Features
ORDER CODE | ITEM | PREREQUISITES | NOTES |
---|---|---|---|
TT06253AA | Add V.24 Wireline Operation | TT4079A or TT4080A or | |
TT4081A | If ordered as field upgrade- Order Code: DDN2634A | ||
TT06319AA | Add Deployment Profiles Capability If the option for |
Deployment Profile Capability is purchased, PDR8000® can be programmed with up
to ten different Deployment Profiles, each uniquely defining the operational
characteristics of the PDR8000®.| TT4079A or TT4080A or TT4081A| If ordered as
field upgrade- Order Code: DDN2633A
TT06582AA| Add DFSI Operation Provides P25 standard IP wireline
fixed station interface.| TT4079A or TT4080A or TT4081A| If ordered as field
upgrade- Order Code: DDN3285A DFSI Protocol Version 1 on the Ethernet
interface. Analog operation (or Mixed-mode operation) is supported on the
Ethernet (DFSI) interface.
Internal Duplexer Options
- Frequency plans that do not meet Futurecom’s specified frequency separation are custom orders.
- Please contact Futurecom to determine if a custom frequency plan is viable and for quotations on viable plans.
- Futurecom.Sales@motorolasolutions.com.
OPTIONS ORDER CODE| ITEM| PREREQUISITES|
NOTES
---|---|---|---
TT06583AA| No Duplexer Required Option| TT4079A or TT4080A or TT4081A|
TT06584AA| Add VHF Duplexer:
· 4.5-5.5 MHz TX to RX Separation
· 300KHz Wide Bandpass
| TT4079A|
TT06585AA| Add 380-430 MHz Duplexer:
· 9.5-10.5 MHz TX to RX Separation
· 300KHz Wide Bandpass
| TT4080A|
TT06586AA| Add 380-430 MHz Duplexer:
· 4.5-5.5 MHz TX to RX Separation
· 300KHz Wide Bandpass
| TT4080A|
TT06587AA| Add 450-470 MHz Duplexer:
· 4.5-5.5 MHz TX to RX Separation
· 300KHz Wide Bandpass
| TT4081A|
CUSTOM FILTERS
TT06579AA| ENGINEERING DESIGN TIME – Non-Recurring Engineering Fee
(NRE)| |
---|---|---|---
TT06580AA| CUSTOM FILTER DESIGN – TIER 1 (Per Unit) ** This option is
for a custom filter design and must be ordered if frequency plans do not meet
Futurecom’s specified frequency separation stated in the ordering guide to
determine if a custom frequency plan is viable, please contact
Futurecom.Sales@motorolasolutions.com
before placing an order.| |
TT06581AA**| CUSTOM FILTER DESIGN – TIER 2 (Per Unit) This option is for a
custom filter design and must be ordered if frequency plans do not meet
Futurecom’s specified frequency separation stated in the ordering guide in
order to determine if a custom frequency plan is viable, please contact
Futurecom.Sales@motorolasolutions.com
before placing an order.| |
4. 50-Watt Booster Power Amplifier Option
OPTIONS ORDER CODE| ITEM| PREREQUISITES|
NOTES
---|---|---|---
TT3936A| VHF 50-Watt Amplifier for PDR8000® Rackmount| TT4079A|
TT3937A| UHF 380-430 MHz 50-Watt Amplifier for PDR8000® Rackmount|
TT4080A| (Not available for sale in Canada)
TT3938A| UHF 450-470 MHz 50-Watt Amplifier for PDR8000® Rackmount|
TT4081A| (Not available for sale in Canada)
PDR8000® Rackmount Options & Spares Ordered Separately
Accessories
ORDER CODE| DESCRIPTION|
---|---|---
TT3935A| Rackmount Alarm capability – contact closure type, temperature,
power|
Software Options
ORDER CODE | DESCRIPTION |
---|---|
DDN2633A | Enable Deployment Profiles Capability |
DDN2634A | Enable V.24 |
DDN3285A | PDR8000® DFSI CAPABILITY – DFSI Protocol Version 1 on the |
Ethernet interface. Analog operation (or Mixed-mode operation) is supported on the Ethernet (DFSI) interface.
Services
Futurecom’s standard hardware warranty is 18 months starting from the date the product ships from Futurecom. Please reference Futurecom’s Terms and Conditions of Sale, Section 7 regarding standard hardware warranty https://www.futurecom.com/terms-conditions/.
ORDER CODE | DESCRIPTION | Notes and Conditions |
---|---|---|
DDN2303A | PDR8000® 4-Year Extended Hardware Warranty | Extends standard |
18-month hardware warranty by 4 years. Can only be purchased once per unit.
Must be purchased before the expiration of the standard hardware warranty.
DDN2302A| PDR8000® 1-Year Extended Hardware Warranty| Extends existing
hardware warranty by one year. Must be purchased before the expiration of any
existing hardware warranty. The standard 18-month warranty can be extended by
a maximum of 4 years.
DDN3699A| On-site and/or Virtual Training (BASIC) 2 Courses Available:
1. Training the Trainer/end-user 1 Day (Est 4 hours) end-user training
gives the end user a general understanding of Futurecom solutions through your
agency’s particular use case, highlighting best practices through situations
commonly seen in the field| Maximum 1 day; see EXTENDED training for
additional days. Minimum 2 weeks advance notice required however subject to
resource availability. Applies to North America only. Training the trainer
requires the newly implemented DVRS/VRX1000/PDR8000® to be tested and in use
ORDER CODE| DESCRIPTION| Notes and Conditions
---|---|---
| during deployment situations. Participants will have hands-on training with
the newly implemented solution for practical operation and control. OR
2. Technical and Programming Training 1 Day Technical and Programming training gives the radio technician an in-depth understanding on how the DVR- LX®/VRX1000/PDR8000® is integrated into the everyday operation of the agency. Highlighting code plug compatibility, Futurecom Repeater Configurator (FRC) software functionality and programming for optimal end-user experience.
| on the network to get the most out of the Training the Trainer. Standard
training package. Includes soft copy of training materials. Customized
training available subject to content and price negotiation. Technical and
Programming Training, Futurecom Systems Group, ULC requires at least two full
functioning Portable radios (PSUs) programmed to the current system, at least
one installed DVR- LX®/VRX1000/PDR8000®. For DVRS and VRX1000 use a Mobile
Radio (MSU) radio set is required to conduct this training properly.
DDN3700A| On-site and/or Virtual Training (EXTENDED)| Must purchase
BASIC virtual training.
- PDR8000® Rackmount Ordering Guide
- PDR8000® – Portable Digital Repeater Rackmount
- Revision 1.4
- July, 2023
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>