WAFERLOCK C760 Euro Smart Cylinder User Manual
- June 14, 2024
- WAFERLOCK
Table of Contents
C760 Euro Smart Cylinder
User Manual
C760 Euro Smart Cylinder
Parts list for the C760 Smart Cylinder
Electronic Cylinder x 1
Battery Installation
- Remove the outer cylinder knob (Pull it out forcefully), and insert a CR2 battery.
- Tighten the screws anti-clockwise with the hexagon key.
Installation Diagram
- Insert the electronic cylinder through the door into the correct position after aligning the cam flush with the cylinder body.
- Tighten the M5 screw fully.
- Insert the inner knob accurately until it reaches the correct position based on your measured thickness. Tighten the screw fully with the hexagon key. (The inside knob of the C760 is adjustable.)
Set Up The Programming Card
Default
Before setting the programming card, it is allowed to use the default pin code
(123456#) and any cards/tags to unlock. After completing the setup of the
programming card, the default pin code (123456#) will be invalid.
The Programming Card must be linked to the lock before any other steps can
take place.
Note
If 2 short beeps occur with the red light flashing 2 times, the setup was not
successful. Please re-program.
- Tap the programming card on the reader, the red light will start flashing for 10 seconds until “1 long beep sound” followed by the green light flashing 3 times.
Note
- Within these 10 seconds, do not remove the programming card away from the reader.
- Programming card is used to add/delete user cards/badges, but not be used to unlock the cylinders.
- Any MIFARE card will be able to unlock the cylinder before it is programmed.
- There is only ONE programming card per cylinder. Please keep it safely.
- You can use one programming card for multiple cylinders.
Lock Setup with App
Follow below steps to get your lock setup with WAFERKEY App. You can also use the mobile App to set up your lock step-by-step and access installation videos.
- Download the App by searching “WAFERKEY” in the App Store (iOS) or on Google Play (Android).
- Open the App, simply use a Third Party Login or register a WAFERKEY account.
- Make sure the lock has been already programmed by the programming card.
- Turn on Bluetooth on your smartphone, stay near the lock and follow the instruction in the App.
- Pair the lock in the App and start to use it.
Note
- The WAFERKEY App works on iPhone with iOS 13.6 or later, or devices with Android 8.0 or later.
- Be sure to accept any available firmware update.
- Please refer to the instruction in WAFERKEY App for more information.
- Once the lock turns to App Mode, ALL the existing user access settings (Key Card, Passcode …) will be deleted.
DON’T WANT TO USE THE APP?
Please go to Standalone Mode page for manual programming instructions.
Questions about your new lock? Let us help you!
support@waferlock.com
Standalone Mode Programming Instruction
WARNING
Standalone Mode programming functions (Programming Card) are NOT available
after the lock is paired with mobile App! If you would like to use Standalone
Mode, please unpair the lock via WAFERKEY App.
Note
- Please remember to set up the programming card, referring to former instruction.
- If 2 short beeps occur with the red light flashing 2 times, the setup was not successful. Please re-do the step again.
Program A User Card
- To add a new user: Tap the programming card on the reader. There will be 2 beeps, and the green light starts flashing. Tap the user card on the reader, and there are 3 beeps. The programming session will be complete until 2 beeps and red light flashes 2 times.
Note
- Program multiple users: The green light will keep flashing for around 10 seconds after 3 beeps which allow you to program multiple user cards constantly.
- Tap the programmed user card while the green light flashing will complete the programming session (instead of waiting for 10 seconds flashing green light).
Unlock / Lock With A User Card
- To lock / unlock: Tap the user card on the reader (1 beep sound and green light flashes 1 time), and rotate the knob to lock / unlock.
Note
The maximum user cards/badges are 2,000.
If reaching the maximum limit, there will be 10 short beeps with red light
alternately flashing 3 times.
Program The Combination
- Tap the programming card on the cylinder 1 time.
- Touch the WAFERLOCK logo for 1 second until the orange light flashes 2 times.
- Rotate the knob with the number to the twelve o’clock position, the number will blink. Once the light is steady, it means the number is chosen.
- After 4-6 digits are correctly chosen, rotate the knob with # to the twelve o’clock position until the numbers flash in order 2 times. The combination is programmed.
Note
- There is only one combination to unlock the cylinder. If new code is programmed successfully, the existing one will be replaced.
- The default combination is 123456. This code will be able to unlock the cylinder before it is programmed.
Unlock / Lock With The Combination
- Touch the WAFERLOCK logo for 1 second until the Green light flashes 2 times.
- Rotate the knob with the number to the twelve o’clock position, the number will blink. Once the light is steady, it means the number is chosen.
- After 4-6 digits are correctly chosen, rotate the knob with # to the twelve o’clock position until the numbers flash in order 2 times, and rotate the knob to lock / unlock.
Note
- If incorrect codes are entered for 5 times, the combination feature will be disabled for 3 minutes with 2 short beeps and the red light flashes 2 times.
- If enter the invalid code 1 time after 3 minutes, the combination feature will be disabled for 3 minutes again.
- Only authorized access can lift the prohibition or until 3 minutes pass.
To delete all users
- Initially, tap the programming card on the reader, then there will be 2 beeps and green light starts flashing. Re-do the same procedure for second time, there will be 2 beeps and green light keep flashing. For the third time, follow the former same steps, and keep tapping card for around 5 seconds until a long beep occurs. The red light will flash 5 times, and all user cards have been deleted.
Low Battery Warning (Battery Replacement)
- If you hear 3 beeps 5 times and the red light flashes 3 times, it means the battery power is low. Please change the battery immediately.
- Fully insert the hexagon key in the screw head and simultaneously turn the screws clockwise to remove the outer cylinder knob.
Your Warranty
Your Warranty covers all manufacturers’ defects in workmanship and material.
It does not cover any unit that is damaged beyond normal usage, by improper
installations, by contacts to chemicals, or any other acts or omissions
unsanctioned within the user manual. All components are covered for one (1)
year after the date of purchase or installation from supplier. The user is
required to provide dated proof of purchase. Wafer lock or its authorized
distributor will determine if there is a warrantable condition associated with
material and/or manufacturing workmanship. If the lock conforms to the
warranty conditions, the lock will be repaired free of charge. The shipping
freights would be at owner’s expense. The warranty does not include any
further obligation whatsoever, including but not limited to the installation
of the replacement unit to the customer’s lock. All other warranties, express
or implied, are disclaimed. All collateral agreements, which purport to modify
this limited warranty, are of no effect.
WAFERLOCK CORPORATION
Tel: 886-4-24620208 Fax: 886-4-24636286
No. 16 Ke Yuan 2nd Rd., Central Taiwan Science Park
Taichung city 407, Taiwan.
E-mail: info@waferlock.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>