AQUAMASTER H600 Pro Handheld Meter pH User Manual
- May 15, 2024
- AQUAMASTER
Table of Contents
AQUAMASTER H600 Pro Handheld Meter pH
Specifications :
- Product : Handheld Meter H600 Pro
- Measures: pH, EC, PPM, TDS, Temperature
- Manufacturer: Aqua Master Tools
Product Information
The Handheld Meter H600 Pro is the ultimate tool for measuring pH, EC, PPM, TDS, and temperature in liquids. Its user-friendly buttons make it easy to switch between parameters. The meter also features a calibration indicator to remind the user when calibration is needed. It comes with a sturdy carrying case for added convenience and safe transport tion.
Usage Instructions:
- Check if the meter is equipped with one 9 Volt battery.
- Connect the pH and EC electrodes to the instrument.
- Remove the pH and EC electrodes’ protective cap.
- Press the on/off button to turn on the meter.
- Immerse the pH and EC electrode in the fluid you would like to test and stir gently until the reading stabilizes.
- Press the Temp button to switch between Celsius and Fahrenheit.
- Press the MODE button to cycle through measurements of pH, EC, TDS, and PPM.
- Press the HOLD button to save the measurement. Remember to press the HOLD button again when using the meter next time.
- Turn off the meter after use.
- Rinse the pH and EC electrodes using tap water to minimize contamination.
- Gently dry the electrodes.
- Replace the EC electrode’s protective cap.
- Fill the pH electrode’s protective cap with storage solution and replace it.
- To maintain continuous usage, keep the electrodes in the testing fluid. Regular calibration is crucial. Inspect for algae growth and clean the electrodes as required.
FAQ :
-
Q: How often should I calibrate the meter?
A: It is recommended to calibrate the meter regularly, especially if you notice any discrepancies in readings or if you haven’t used the meter for an extended period. -
Q: Can I use the meter for testing liquids other than water?
A: Yes, you can use the meter to test various liquids such as those in swimming pools, aquariums, Jacuzzis, ponds, and liquid plant nutrition solutions.
Handheld Meter H600 Pro Measures pH EC PPM TDS Temp
User manual
About Aqua Master Tools
- Established in 2018
- Aqua Master Tools is the Dutch supplier of user-friendly and reliable pH, EC, and temperature meters. Our meters are used for swimming pools, aquariums, Jacuzzi’s, ponds, and liquid plant nutrition.
- We understand the importance of convenient, accurate and high-quality meters – and we are on a continuous quest to innovate our products. Aqua Master Tools’ wide range of products are customised to our user’s needs.
Satisfaction guaranteed
- Easily replaceable electrodes
- Built to last products
- Fully calibrated meters
- Unprecedented quality
Visit www.aquamastertools.com or scan the QR code to watch our HOW-TO VIDEOS
User manual
-
Battery indicator
-
Display
-
On/off button
-
HOLD button
-
Calibration indicator
-
MODE & EC CAL button
-
Temp. & pH CAL button
-
pH electrode port
-
EC electrode port
-
EC electrode
-
pH electrode
-
Protective cover
Thank you for choosing Aqua Master Tools Handheld Meter H600 Pro.
The Handheld Meter H600 Pro is the ultimate tool for measuring pH, EC, PPM,
TDS, and temperature in liquids. Its user-friendly buttons make it easy to
switch between parameters. The meter also features a calibration indicator to
remind the user when calibration is needed. It comes with a sturdy carrying
case for added convenience and safe transportation.
Operation and use
Watch the How-to videos at Aqua Master Tools’ website.
- Check if the meter is equipped with one 9 Volt battery.
- Connect the pH and EC electrodes to the instrument.
- Remove the pH and EC electrodes’ protective cap.
- Press the on/off button to turn on the meter.
- Immerse the pH and EC electrode in the fluid you would like to test and stir gently until the reading stabilises.
- Press the Temp button to switch between Celsius and Fahrenheit.
- Press the MODE button to cycle through measurements of pH, EC, TDS and PPM.
- Press the HOLD button to save the measurement. Do not forget to press the HOLD button again when the meter is used once more.
- Turn off the meter after use.
- Rinse the pH and EC electrodes using tap water to minimise contamination.
- Gently dry the electrodes.
- Replace the EC electrode’s protective cap.
- Fill the pH electrode’s protective cap with storage solution and replace it.
- You can maintain continuous usage of the meter by keeping the electrodes in the testing fluid. Please note, that regular calibration is necessary then. It is crucial to periodically inspect for algae growth and carefully clean the electrodes as required.
pH calibration
Watch the How-to videos at Aqua Master Tools’ website.
- Ensure that the pH electrode is connected to the handheld meter.
- Turn on the meter by pressing the On/Off button.
- Press the MODE button to switch to pH mode on the display.
- Remove the pH electrode’s protective cap.
- Gently clean the electrode with distilled water and dry it off.
- Insert the pH electrode in pH buffer solution pH 7.00 (make sure this is 25°C) and stir gently.
- Wait until the value on the display is stable.
- Press and hold the pH CAL button for 5 seconds until the value of the buffer solution is displayed. The meter will automatically recognise the buffer solution and calibrate itself. As soon as the meter switches back to the standard mode, calibration is complete.
- Gently clean the electrode with distilled water and dry it off.
- Insert the pH electrode in pH buffer solution pH 4.01 (make sure this is 25°C) and stir gently.
- Wait until the value on the display is stable.
- Press and hold the pH CAL button for 5 seconds until the value of the buffer solution is displayed. The meter will automatically recognise the buffer solution and calibrate itself. As soon as the meter switches back to the standard mode, calibration is complete.
- After a successful 2 point calibration, the CAL logo ( calibration reminder indicator ) will appear at the bottom right of the screen.
- Rinse the pH electrode in tap water.
- Fill the pH electrode’s protective cap with storage solution and replace it.
Please note that if the meter displays an error during calibration, either the buffer solution does not have the correct value or the electrode is dirty or worn and has to be replaced.
EC, TDS, PPM calibration
Watch the How-to videos at Aqua Master Tools’ website.
- Make sure the EC electrode is connected.
- Turn on the meter by pressing the On/Off button.
- Press the MODE button to switch to EC mode on the display.
- Remove the EC electrode’s protective cap.
- Gently clean the electrode with distilled water and dry it off.
- Insert the EC electrode in calibration solution (uS/cm 1413) mS/cm 1,41 EC (make sure this is 25°C) and stir gently.
- Allow the reading to stabilise.
- Press and hold the EC CAL button for 5 seconds until the value of the calibration solution is displayed. The meter will automatically recognise the buffer solution and calibrate itself. As soon as the meter switches back to the standard mode, calibration is complete.
- After a successful EC calibration, the CAL logo (calibration reminder indicator) will appear at the bottom right of the screen.
- Rinse the electrode with tap water and dry it.
- Replace the EC electrode’s protective cap.
Calibration indicator
The calibration indicator will appear after successfully calibrating pH or EC.
The indicator will disappear after 30 days as a reminder that the device needs
to be recalibrated.
When is calibration required
- If the electrode has been replaced.
- If the meter was last calibrated over a month ago.
- If the meter is used on a regular basis.
- If high precision is needed.
Replacing the battery
The battery need to be replaced according to the battery indicator. Or if the
meter no longer turns on then replace the 9 Volt battery.
Warning
- If your meter is not working properly, watch the troubleshooting videos on the product page of our website aquamastertools.com
- Always make sure that there are no air bubbles present in the solution during calibration. This could affect the measurements.
- If the EC value does not decrease to 0, insert the electrode into ethyl alcohol and shake gently for 5 to 10 seconds.
- Make sure the calibration solution is 25ºC when calibrating the meter. Failure to do so may affect the result of the calibration.
- Never store the electrode in distilled water.
- DO NOT immerse the electrode in oil, proteins or suspended solids that leave a layer on the glass bulb.
- DO NOT soak in RO (Reverse Osmosis), distilled or deionised water. Pure water alters the chemistry of the reference liquid so that it no longer works.
- DO NOT place a cold electrode in hot liquid (or vice versa). Sudden changes in temperature may break the glass and permanently damage the pen. Broken glass is not covered by the warranty.
- Make sure not to bump the glass electrode into anything, because this might break the glass bulb on the outside of the internal glass tube. Broken glass is not covered by the warranty.
- Avoid placing the meter near ballasts or any other electrical appliances. Force fields may affect the readings.
- If during calibration the pH/EC value slowly keeps rising or dropping and does not stabilise, please replace the batteries and calibrate the meter. Bad batteries or low power levels may influence the measurement results.
Warranty
This meter is warranted from all defects in material and manufacturing for a period of one year from the date of purchase. The electrode is warranted from all defects in material and manufacturing for a period of six months from the date of purchase. If during this period any parts need reparation or replacement and the damage is not due to incorrect operation by the user, please send the parts to the dealer or to us and the repair will be free of charge. Please refer to the exclusion warning.
Specifications
Range|
- pH: 0.1 ~ 14.0 pH
- EC: 0.0 ~ 19.9 mS/cm
- TDS: 0.0 ~ 19.99 PPT
- PPM: 0.0 ~ 1999 PPM
- Temperature: 0°C ~ 50°C (32°F ~ 122°F)
---|---
**** Resolution|
- pH: ± 0.1 pH
- EC: 0.1 mS/cm
- TDS: 0.01 PPT
- PPM: 10 PPM
- Temperature: 0.1°C (1.0°F)
**** Accuracy|
- pH: ± 0.1 pH EC: ± 2% F.S. TDS: ± 2% F.S. PPM: 10 PPM
- Temp: ±0.5°C (32°F)
- Temp. compensation: 0°C – 50°C (32°F – 122°F)
PPM scale| 700 PPM
Calibration|
- pH: 2 point auto calibration pH 7.0 – 4.0
- pH EC : EC 1.4 (1413 µS/cm)
Calibration indicator| After successful calibration, disappears after 30 days
Features| Battery indicator & automatic temp. compensation
Power supply| 1 x 9 Volt battery (included)
Auto. power-off| After 8 minutes
Waterproof| Electrodes IP67, Meter IP62
Dimensions| 210 x 120 x 60 mm
Weight| 430 grams
Aqua Master Tools
www.aquamastertools.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>