NOD UPS Untitled Line interactive User Manual

May 15, 2024
NOD

NOD UPS Untitled Line interactive

NOD UPS Untitled Line interactive

Thank you

Thank you for choosing our product. We hope you will enjoy using the appliance.

SYMBOLS IN THESE INSTRUCTIONS FOR USE

Important information for your safety is specially marked. It is essential to comply with these instructions in order to avoid accidents and prevent damage to the machine:

WARNING: This warns you of dangers to your health and indicates possible injury risks.
CAUTION: This refers to possible hazards to the machine or other objects.
NOTE: This highlights tips and information.

GENERAL NOTES

Read the operating instructions carefully before putting the appliance into operation and keep the instructions including the receipt and, if possible, the box. If you give this device to other people, please also pass on the operating instructions.

GENERAL SAFETY INSTRUCTIONS

  1. Check that the voltage indicated on the device rating label corresponds to the voltage in the mains.
  2. Always plug the UPS into an outlet that is earthed. Risk of electric shock!
  3. Do not use the device outdoors.
  4. Do not place/ use the UPS near dusty areas.
  5. You shall keep the device away from sources of heat, direct sunlight, humidity (never dip it into any liquid) and sharp edges.
  6. Do not use the device with wet hands. Risk of electric shock.
  7. Do not place /use the UPS on or near flammable material and sources of heat.
  8. Do not place / use the device near places with very high or very low temperatures (above 40°C or below 0°C).
  9. Do not place/ use the device near places with a very high humidity level (above 90%).
  10. Do not place/ use the device near places with severe vibration.
  11. You shall charge the UPS battery for at least 8 hours before using the device for the first time.
  12. If the UPS is not used for a long time, charge the battery for at least 8 hours before use it in order to avoid damage.
  13. UPS is designed exclusively for use with computers only. Do not connect the device to other induction or capacitive load devices e.g., laser printers or scanners.
  14. It is prohibited to use the UPS with vital support devices because in the event of failure, the devices will stop working. Violation of this particular security and liability is solely the responsibility of the user.
  15. WARNING: Do not operate the device with a damaged cord. In order to avoid the risk of an electric shock, never try to repair the device by yourself. Bring it to the authorized service station for repair.
  16. WARNING: It is hazardous for anyone other than a trained person to carry out any service or repair operation which involves the removal of cover of UPS. To reduce risk of electric shock, UPS should be only be opened by an authorized technician when service is required.
  17. WARNING: Do not place objects containing water or any other liquid on the UPS in order to avoid the risk of a short circuit. Risk of electric shock! Risk of fire!
  18. To protect again electric shock, do not immerse the cord, plug or unit in water or any other liquid.
  19. In case of fire, use a dust extinguisher. The use of a liquid extinguisher is prohibited. Risk of electric shock!
  20. Do not place objects on the UPS.
  21. CAUTION: Do not connect devices load higher than UPS can handle.
  22. You must place the device on a flat and stable surface.
  23. Keep a distance of at least 15cm around all sides of UPS.
  24. When cleaning or storing the device, switch off the device and always pull out the plug from the socket (pull the plug, not the cable).
  25. Keep the device and its cord out of the reach of children.
  26. In order to ensure your children’s safety, please keep all packaging (plastic bags, boxes, polystyrene etc.) out of their reach.
    WARNING: Do not allow small children to play with the foil. Danger of suffocation!

PARTS IDENTIFICATION

FRONT PART

  1. Power ON /OFF button

  2. LED light indications

  3. Ventilation holes
    BACKSIDE PART

  4. Outputs

  5. Power cord
    Parts Identification

LED LIGHT INDICATIONS AND NOTIFICATIONS

STATUS| LED| SOUND NOTIFICATION|

NOTES

---|---|---|---
|

650VA \ 850VA \ 1200VA \ 15OOVA \ 2000VA

AC Power supply

|

Green LED light (AC power on)

| |

Yellow LED light flash is every 20 sec charging

| |

Yellow LED light (battery fully charged)

| |

Battery (DC) power supply

|

Red LED light

|

Sound notification every 6 seconds

|
Exhausted battery or battery overheat|

Red LED light

| Continuous sound notification|

Notice to close the computer

TECHNICAL SPECIFICATIONS

MODEL 650VA 850 VA 1200 VA 1500VA 2000VA
Input voltage 220V AC± 25% (5% adjustable)
Input frequency 50Hz /  60Hz ± 6%
Output frequency 50Hz /  60Hz ± 1%
Output voltage 220V AC (±5%, p adjustable)
Transfer time <10ms
Waveform type Sine wave under constant grid voltage, Square waveform during

battery operation
Overload protection| Safety for overload
Short circuit protection| Safety for power failure and short circuit operation
Battery backup time| 15 – 35 min (depending on the load)
Battery type| 12V 7.2Ah x1| 12V 9Ah x1| 12V 7.2Ah x2| 12V9Ah x2 | 12V 9Ah x2
Battery protection| Automatic operation control, discharge protection and battery error warning
Battery charging time| 6 hours for 90%
Battery life time| 3 months
Low battery sound notification| Sufficient battery capacity- Sound notification every 6 seconds\ LED light flashes
Insufficient battery capacity- Sound notification every 1 second\ LED light flashes
Battery/ overload/ short circuit sound notification| Continuous sound notification\ LED light is ON
Temperature| 0°C-40°C
Humidity| 0%-90%
Noise| < 40dB at 1.0m distance
Schuko outputs| 2| 2| 4| 4| 4
Net weight (Kg)| Ska| 5,75ka| 9,25ka| 11,70ka| 13,20ka
Device dimensions (mm):| 394x145x210 I| 394x14sx210 I| 405x243x295 I| 44sx22sx2so| 445x225x290

USING THE UPS

  1. Before using the UPS for the first time, check that the voltage shown on the device rating label corresponds to the voltage in the mains.
  2. Charge the battery for at least 6-8 hours before use it in order to avoid damage.
  3. Turn the devices off and disconnect them from the power supply.
  4. Connect the load (e.g. computer) to the outlet on the back side of UPS.
  5. Connect UPS to the power supply.
  6. Press the UPS power button for 2 seconds and the green LED will illuminate.
  7. Turn on your computer.

Test that the UPS is working properly:

Let the UPS work in battery mode for a short period of time.

  1. Disconnect the UPS power plug in order to simulate a power failure.
  2. An audible alarm should sound and the red LED will light.
  3. If it works as above, then UPS is working properly. Otherwise contact the retail store that you  bought the device or the authorized service.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
LED light indication s do not light up. Problem with power supply Check that

the power cord is properly connected.
Burned fuse on the back side of the UPS| After unplugging, take the fuse out and check if it is burned or not. In case that fuse is burnt , you should contact the authorized service.
The UPS switch es on in less than 3 seconds| To turn on the UPS you need to press the power button for more than 3 seconds.
The UPS do es not work through AC power (AC) (you have plugged in the device, power outlet has been switched on and you have pressed the power button but the LED light does not light up and audible notification sounds).| Problem with power supply| Check that the power cord is properly connected.
Burned fuse on the back side of the UPS| After unplugging, take the fuse out and check if it is burned or not. In case that fuse is burnt, you should contact the authorized service.
The red LED light s up and an audible notification s sounds continuously.| Overload \ Battery volt age is too low| Reduce the load \ Charge the battery for at least 8 hours
Battery discharge time is short er than usual.| The battery is not charged properly| Charge the battery for at least 8 hour s and double check the discharge time. If the discharge time is again short er than usual, you should contact the authorized service .
Faulty battery
Problem while charging the battery

CLEANING

  1. Always unplug the device before cleaning it.
  2. Clean the device housing with a damp cloth.
  3. Do not use anything abrasive that can scratch or damage the device.
  4. Do not use a wire brush or other abrasive utensils for cleaning.

STORAGE

  1. Always unplug the device before storing it.
  2. Always store the device in a safe and clean place. For the better protection of the appliance, store it in its original packaging.

DISPOSAL OF APPLIANCE AND ACCESSORIES

This symbol appearing on the product, its accessories or accompanying manuals indicates that the product and its electronic accessories should not be disposed of with other household trash.

In order to avoid possible harmful effects on the environment or health due to uncontrolled waste disposal, please separate these products from other types of waste and recycle them. Household users should contact either the store where they purchased this product or their local services for details of where and how they can return these products for environmentally safe recycling.

DISPOSAL OF BATTERIES
This marking on the battery, manual or packaging indicates that the batteries of this product should not be disposed of with other household waste at the end of their life cycle.

Customer Support

lonias Kalochori, 570 09 Thessaloniki, Greece, TEL. +30 23 l 0 700.777
e-mail:
[email protected] / www.nod.com.gr

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NOD User Manuals

Related Manuals