iDTRONIC 2400 Swing Gate
Product Structure and Working Principle
The electronic control system of the channel gate
The electronic control system consists of the card reader, main control board,
infrared sensor, direction indicator board, alarm, transformer, etc.
-
Card reader (self-provided): after reading the information on the card and judging and processing, send the application pass signal (switch signal) to the main control board.
Master control board: the control centre of the system, which receives signals from the card reader and infrared sensor, makes logical judgments and processing of these signals, and then issues execution commands to the direction indicator, motor, counter and alarm. -
Infrared sensor: detect the pedestrian position and play the role of safety protection.
-
Direction indicator light : displays the current status of the channel and guides pedestrians to pass through the channel in a safe and orderly manner.
-
Alarm: when the system detects pedestrians entering the passage illegally, it will send out an alarm
Operating principle of the system
- Turn on the power and the system will enter into the working state after 3 seconds.
- When the card reader reads the valid card, a pleasant sound will play, indicating to pedestrians that the card has been read successfully.
- The reader receives the signals from the backend database and after comprehensive processing, sends effective control signals to the direction indicator and motor, so that the direction indicator sign turns into the green arrow pass sign. At the same time, the turnstile sends the setting voice, the main control board controls the motor operation, and the gate is opened to allow pedestrians to pass. Otherwise, entrance will not be granted with red indicator lights.
- After the pedestrian passes through the channel according to the direction indicator, the infrared sensor senses the whole process of the pedestrian passing through the channel and continuously sends signals to the main control panel until the pedestrian has passed through the channel completely.
- If entered without permission, the alarm will go off until the passage is cleared again.
Installation instructions
Installation notes & suggestions
Note: Disconnect all circuits during installation
Installation Suggestion
- Cables should run in ductwork at 60mm depth to end up between mounting frames.
- If the turnstiles are installed outside, consider a higher depth for the ductwork.
- The installation should be done without any power connections to the gate.
- After the hole location is determined, drill the hole and embed the anchor bolt or expansion bolt of M12. Concrete of at least 60mm thickness is recommended.
- If you install multiple devices please make sure to align them properly before drilling holes.
- Connect the power line and control line according to the wiring diagram and connect the system protection ground wire.
- After successfully anchoring and checking wiring turn on the power.
- After completion of the installation, check the connection condition of the earth wire, connector assembly for the connecting line and all moving parts with the device. Make sure the connection is firm in order to prevent failure caused by long time operation. If any screw or part is not tightened, please tighten it.
Figure 3 – locations inside the gate
- circuit board
- power supply
- air break switch
Figure 4 – product dimensions
Turnstile adjustme nts & connections
Gate Position Adjustment
Adjustment method for door panel position in Swing Gate Mode:
- Press the INC button (middle button) 5 times in a row, and the system will prompt “Please manually adjust the position of the wing gate” and enter the wing gate (door panel) adjustment mode.
- Push the door panel to the target position and stop, keep it still for 3 seconds, and the voice prompt “beep” or corresponding light flashing indicates that the current position has been sampled.
- he system will automatically determine whether the current sampling position is left in place, right in place or zero position based on the position of the wing gate.
- Finally, push the door panel back to the center alignment and keep it still for about 10 seconds. The system will prompt “Setting completed, welcome to use” and exit the adjustment mode.
- n most cases, the system will automatically obtain appropriate left and right positions. Users only need to adjust the zero position, align the wing gate, and wait for the system to exit automatically
Adjustment method for door panel position in Flap Gate Mode
- Press the SET button (middle button) 5 times in a row, and the system will prompt “Please manually adjust the position of the wing gate” and enter the wing gate (door panel) adjustment mode.
- The “left open” and “right open” buttons on the main control board can control the main motor to move back and forth, and the “left open” and “right open” buttons on the sub-control board can control the sub-motor to move back and forth. Use the buttons to control the wing gate to move to the target position and stop, keep it still for 3 seconds, and the voice prompt “beep” or corresponding light flashing indicates that the current position has been sampled.
- The system will automatically determine whether the current sampling position is left in place or right in place based on the position of the wing gate.
- Press and hold the middle button for more than 2 seconds and release it, and the program will exit the adjustment mode.
Figure 5 – Mainboard description
- OP-L = open left
- OP-R = open right
- Fire = emergency exit connection
- Red/blue marked buttons = setting/testing of parameters
- power +/- = connect power 230V
- counter = count up/down for external use
Parameter Setting
- Press and hold the INC button (middle button) until the digital tube flashes to enter the parameter setting.
- The first and second digits of the digital tube display the menu, and the third and fourth digits display the value. Press the left button to set the menu and the right buttons to set the value.
- Press and hold for about 2 seconds, and the digital tube will stop flashing. The menu value is successfully saved.
Example: A s shown in the figure, the current menu is “gate opening mode”, and parameter 02 represents “left infrared free passage”
No. | Function | Range | Default | Details |
---|
1
| ****
Gate opening mode
| ****
1~6
| ****
1
| 1: Standard mode. 2: Left infrared free passage. 3: Right infrared free passage. 4: Left and right infrared free passage. 5: Turnstile normally
open. 6: Turnstile normally closed.
The top light board will move accordingly during adjustments. The direction of “infrared free passage” is displayed with lighted-up
arrows.
2| Gate opening time| 1~90| 8| Time unit: seconds. Plus and minus button to in- or decrease time
3
| ****
Left gate opening voice prompt
| ****
0~9
| ****
0
| 0: Thank you; 1: Please pass; 2: Goodbye; 3: Welcome; 4: Welcome again; 5:
Have a safe journey; 6: Have a pleasant trip; 7: Wear a safety helmet; 8:
Verification successful; 9: Mute;
4| Right gate opening
voice prompt
| 0~9| 3| s.a.
5| Voice volume| 1~9| 5| Plus and minus button to in- or decrease the volume
of prompts
6| Main motor speed| 1~25| 13| When the combination gear ratio of the motor
and the movement mechanism is too low or high, this setting must be adjusted.
7| Slave motor speed| 1~25| 13
9
| ****
Deceleration interval
| ****
1~30
| ****
10
| This parameter is set for a smooth opening/closing of the gate
If the wing gate does not stop in place smoothly and crawls slowly,
consider reducing the parameter;
if the wing gate stops suddenly and shakes significantly, consider
increasing the parameter.
12
| ****
Close gate control
| ****
0~9
| ****
2
| 0: Start closing while ongoing passage 1: start closing at the end of
the passage
---|---|---|---|---
2: start closing after the passage
3-9: Additional delay (n-2 seconds) after passage is completed
13| Single motor mode| 0~1| 0| 0: Double motor mode (for two-way passage). 1:
Single motor mode
(for one-way passage).
15
| Obstacle detection,
infrared anti-pinch rebound
| ****
0~1
| ****
1
| 0: Obstacle detection => Gate stays in place. 1: Obstacle detection
=> gate opens fully again
16| Mechanical anti-pinch
sensitivity
| 1~9| 5| The higher the value, the higher the sensitivity.
19
| ****
Power-off gate opening direction
| ****
0~2
| ****
2
| 0: Open the gate to the left after power failure.
1: Open the gate to the right after power failure.
2: The system automatically selects the power-off gate opening
direction based on the current situation.
The gate opening direction can be referenced to the arrow direction
on the top light board.
22| Left and right infrared
effective signal delay
| 1~9| 5| Time = parameter * 20 milliseconds (default 100ms)
27
| ****
Anti-pinch priority setting
| ****
0~1
| ****
0
| 0: Fast passage mode, priority to open the gate, infrared anti-pinch is invalid during the gate opening process, and the gate can be
opened when there is a signal from the left and right infrared;
1: Safe passage mode, priority to anti-pinch, infrared anti-pinch is valid during the gate opening process, and the gate cannot be
opened when there is a signal from the left and right infrared.
32| The main motor sliding
compensation
| 0~9| 0| If the switch gate panel cannot return to the starting position
immediately after the self-check is completed, the sliding compensation can be
increased appropriately.
33| Slave motor sliding
compensation
| 0~9| 0
Product Maintenance
Maintenance
- To avoid the risk of electric shock, always ensure the power is off before inspecting inside parts.
- We suggest inspecting/testing the turnstile regularly to ensure a proper working condition.
- The material is made of stainless steel, please use suitable cleaners.
Tips and Troubleshooting
- if the gate is not opening after a successful reading process, please recheck whether all wires well connected and the card is considered “valid” by our backend system.
- If the indicator doesn’t light, or indicates the wrong direction, please contact us to check any faulty wirings.
- The turnstile will automatically open after power off; if it does not, there is a faulty battery – please contact us for a replacement.
- The arms open normally but fail to close, check the infrared sensor if it matches well and is clean.
Safety Hints
- Before installation, maintenance or repair turn off power.
- Do not change the inside wiring, take a photo before any disconnection.
- For your own safety please only let specialized professionals change any wiring or do repairs on the electronic parts of the gate. Please also consider that the warranty will expire as soon as you change any wiring etc. on the inside on your own and without consultation of an iDTRONIC employee.
- Do not use the built-in power supply to connect any other third-party device if told so by an iDTRONIC employee.
- Do not operate when thundering and lightning to prevent any damage to the electrical parts of the turnstile.
Support