PowerCom LT-2815 Universal Alarm Communicator Installation Guide
- May 15, 2024
- POWERCOM
Table of Contents
- PowerCom LT-2815 Universal Alarm Communicator
- Product Usage Instructions
- ABOUT THE COMMUNICATOR
- SYSTEM COMPONENTS
- APPLICATIONS
- ACTIVATE THE CELLULAR MODULE
- PROGRAMMING
- INITIALIZATION
- COMMUNICATION
- NETWORK OPTIONS
- REMOTE OPTIONS
- SYSTEM REPORTS
- SYSTEM OPTIONS
- OUTPUT OPTIONS
- AREA INFORMATION
- ZONE INFORMATION
- SET LOCKOUT CODE
- APPENDIX
- Using the 984 Command Function
- Using the Walk Test
- ADDITIONAL INFORMATION
- FCC NOTICE
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PowerCom LT-2815 Universal Alarm Communicator
Specifications
- Product: Universal Alarm Communicator
- Communication: Cellular Module
- Programming Options: Account Number, Transmission Delay, Communication Type, Backup Cell
- Network Options: DHCP Mode, Local IP Address, Gateway Address, Subnet Mask, DNS Server, Programming Port
- Remote Options: Remote Key, Remote Disarm, App Key
Product Usage Instructions
Programming
Before you begin programming, ensure you have all necessary information
such as account number and communication settings.
- Access the Programming Menu to start configuring the settings.
- Reset Timeout if needed for specific actions.
- Use Special Keys for quick access to certain functions.
- Enter Letters and Special Characters as required.
- Review Current Programming before finalizing.
Initialization
Initialization options allow you to reset and clear various settings:
- Clear All Codes
- Clear All Schedules
- Clear Events
- Clear Zone Programming
- Clear Communication
- Set to Factory Defaults
Communication
Configure communication settings for seamless operation:
- Set Account Number for identification.
- Adjust Transmission Delay if necessary.
- Select Communication Type based on requirements.
- Backup Cell option for redundancy.
- Schedule Test Time for regular checks.
Network Options
Customize network settings for optimal connectivity:
- Enable DHCP Mode for automatic IP assignment.
- Set Local IP Address, Gateway Address, and Subnet Mask.
- Configure DNS Server settings.
- Define Programming Port for data transfer.
Remote Options
Enhance remote accessibility with the following options:
- Assign Remote Key for remote access.
- Enable Remote Disarm feature for convenience.
- Utilize App Key for app integration.
Frequently Asked Questions (FAQ)
-
Q: How do I activate the Cellular Module?
A: To activate the Cellular Module, follow the steps outlined in the ‘Activate the Cellular Module’ section of the manual. -
Q: How can I clear all codes on the communicator?
A: Navigate to the Initialization section and select the ‘Clear All Codes’ option to remove all stored codes.
PROGRAMMING AND INSTALLATION GUIDE
Universal Alarm Communicator
Digital Monitoring Products, Inc.
© 2024
ABOUT THE COMMUNICATOR
- The PowerCom™ provides primary network communication, secondary cellular communication, two sets of tip and ring terminals, as well as a 24 hour backup battery, red enclosure and a Model 685-R (Red) Backbox.
- The communicator also provides four input zones and two open-collector outputs for connection to control panel outputs and zones. Connect to the bell output of an existing control panel using zone 4 on the communicator. The communicator operates in a variety of applications: CID Dialer Connection, Zones 1-4 Input Connections, or Zone 4 Bell Connection. See Applications.
Features
- Can be powered from 12 VDC or 24 VDC
- 24 hour backup battery
- Zone 1-4 terminals with 12 V and 24 V power input
- EASYconnect™
- 2 sets of tip and ring terminals
- Programming header for connecting to a programming keypad
- LED to indicate armed state
What is Included
- PCB with enclosure
- Model 685-R Backbox
- Hardware pack
- External antenna
- Plug-in Power Supply, 372-500-W
- 24 hour backup battery
SYSTEM COMPONENTS
Terminals
-
Power Connection Terminals
The communicator may be powered from the included Model 372-500-W plug-in DC power supply or 24 VDC auxiliary output of the control panel. -
PowerCom Standby Power
During a power outage, the communicator draws power from 24 hour a backup battery included in the unit within the enclosure. -
Zones 1‑4
Terminals Z1 to Z3, G (ground), Z4+ and Z4- provide four zones to connect to individual relay outputs on the control panel. Zone 4 (Z4+ and Z4-) can be connected to the control panel bell output. See Zone 4 Bell Connection. -
Open‑Collector Outputs
Terminals O1 and O2 can be programmed to indicate the activity of the zones or conditions occurring on the system. Open-Collector outputs do not provide a voltage but instead switch-to-ground the voltage from another source. Maximum voltage is 30 VDC at 50 mA. The outputs can respond to any of the conditions listed below:- Activation by zone condition: Steady, Pulse, Momentary, or Follow
- Communication
- Armed area annunciation
- Remote Arming Output
-
Dialer Connection
Directly connect the Telco phone line (tip and ring) from the control panel to the terminal R (Ring) and one into terminal T (Tip). For more information, refer to “CID Dialer Connection”. -
Programming (PROG) Connection
A 4-pin programming header is provided to connect a keypad when using a DMP Model 330 programming cable. This provides a quick and easy connection for programming the communicator. For 24 VDC applications using the communicator, connect the keypad using a Model 330-24 4-wire programming harness with an in- line resistor. After programming is complete, remove the keypad. -
Caution: If connecting to a 24 VDC control panel, do not connect a keypad using a Model 330 harness.
-
Tamper
The tamper is pressed when the cover of the communicator is secured onto the enclosure. When the cover is removed, the communicator sends a tamper trouble message to the central station. -
Reset Button
The reset button is located on the upper right side of the circuit board and is used to reset the communicator. After resetting the communicator, begin programming within 30 minutes. If you wait longer than 30 minutes, reset the communicator again.
Note: After the panel is reset, cell suppression is disabled for 30 minutes.
Performing a Firmware Update
Firmware can be updated with the programming header. Firmware updates are
available for download, free of charge, on the DMP Dealer Direct website at
Product Software Downloads.
Dealer Admin
- Log in to dealer.securecomwireless.com .
- Select the PowerComF system connected to the account.
- The System Information page opens. Go to Remote Update.
- If there are any available updates, select Update System.
Model 401 USB Flash Module
- Caution: Do not connect a Model 401 to the communicator if using 24 V power.
- When loading the firmware RU file onto a USB drive, place the file in the root directory of the USB drive. The update cannot be inside a folder. Format the USB drive as FAT32.
- Place only one firmware file in the root directory. If more than one RU file exists on the USB drive, the communicator will choose the RU file with the most recent date modified.
Caution: Using the wrong RU file for the update will cause the communicator to stop working until the correct RU file is used to flash the firmware.
-
Connect the USB flash drive to the Model 401.
-
Press and hold the reset button on the communicator. You will continue to hold reset until step 6.
-
Connect the assembly to the communicator’s programming header.
-
Press and release the button on the Model 401.
-
With your finger still on RESET, press and hold the load button. Continue to hold LOAD until step 8.
-
Release the reset button.
-
Press and release the button on the Model 401.
-
When the green LED on the Model 401 starts a slow flash, release the load button. The slow flash will last 5 minutes, then the green LED will become steady, indicating the firmware version is updated.
Note: If the LED blinks rapidly, the update was unsuccessful. Press and release RESET. Begin again at step 1. -
Press and hold RESET. Remove the Model 401, then release RESET to resume normal operation.
In the event the Model 401 USB Flash Module is inadvertently removed from the communicator before the update finishes, repeat steps 1-9.
Backlit Logo
The backlit logo indicates the power and armed status of the communicator.
Depending on the operation, the LED displays in red or green. The LED
indicates the armed state and status of the system primary power.
ARMED STATE | POWER STATE | GREEN LED | RED LED |
---|---|---|---|
Disarmed | AC/Battery Good | On | Off |
AC Bad | Off | Off | |
AC Good/Battery Bad | Flashing .5 seconds on/off | Off | |
Armed | AC/Battery Good | Off | On |
AC Bad | Off | Flashing .5 seconds on/off | |
AC Good/Battery Bad | Alternate between Red/Green every .5 seconds |
Mount the Enclosure
- For Commercial Fire applications using the PowerComF and the included red plastic Model 685-R backbox, mount the backbox to the wall with the 1” #6 screws included with the fire communicator.
- Place the battery in the backbox and route the wires through the cutouts. Connect the battery lead connector to the PowerComF header.
- Note: The PowerComF is shipped with double sided tape that can be used to install the battery. Do not use double sided tape for listed installations.
- Mount the fire communicator to the backbox with the 1/2” #6 screws. See Figure 1. Locate the fire communicator within 20 feet of the control panel and route all wire in conduit.
- Note: To find the cellular provider on the PCB, see callout K below.
Wire the Communicator
When connecting component wires, route all wires so they will not interfere
with the tamper switch. See Figure 3 for wire routing options.
Connect the Antenna
- Place the antenna onto the SMA connector. Refer back to Figure 3. Twist the antenna until it is securely tightened.
- Replace the housing cover on the mounted base. Be sure to not damage any PCB components when removing or replacing the housing cover.
Connect DC Power
Caution: Mount the PowerComF near a wall outlet for the Model 372-500-W
plug-in DC power supply. In addition to powering the PowerComF, the plug-in DC
power supply also charges the back-up battery. The 372-500-W must be located
within 100 feet of the PowerComF using 22 AWG wire.
- Using 22 AWG wire, connect the PowerComF DC terminal (+) to the positive terminal on the power supply.
- Connect the PowerComF DC terminal (-) to the negative terminal on the power supply.
- Plug the power supply in a 120 VAC 60 Hz dedicated outlet not controlled by a switch.
- Connect AC and Battery Trouble Relays to the PowerComF
- Connect AC TRBL relay outputs from NC (normally closed) and C (common) to an available zone on the PowerComF. Add a 1k reisistor in sequence and program as a Supervisory zone.
- Connect BATT TRBL relay outputs from NC (normally closed) and C (common) to an available zone on the PowerComF. Add a 1k resistor in sequence and program as a Supervisory zone.
- Wiring Specifications
Use 18 AWG or larger for all power connections. Ensure there is a minimum 0.25” space to keep power limited wiring separate from non-power limited wiring (120 VAC/60 Hz input, battery wires).
APPLICATIONS
CID Dialer Connection
- Directly connect one or both tip and ring terminals from the control panel to the communicator. See Figure 4.
- Note: Do not connect telephone company wires to the communicator. Remove any connected telephone company wires from the control panel.
- This connection captures Contact ID messages from any fire panel that are based on the SIA communication standard DC-05-1999.09-DCS. Messages are then formatted into a Serial 3 message and sent to an SCS-1R Receiver or SCS-VR Receiver.
- Messages can also be sent as a DMP string with raw CID message appended. See Figure 5. This feature requires SCS-VR Version 1.4.6 and higher or SCS-150 Version 107 and higher.
Communication Failure
The phone line voltage on the second tip and ring will drop when the PowerComF
is in a communication failure state. This triggers the host panel to
annunciate a communication failure. When communication is restored, voltage is
restored on the second tip and ring terminal and the host panel sees a
restoral on the phone line.
ACTIVATE THE CELLULAR MODULE
For more information about using Dealer Admin or Tech APP, refer to DMP’s Help Files page.
Dealer Admin Activation
- Find the customer and select their name.
- The customer’s summary page opens. In the Systems section, press the Add icon.
- Enter the system name.
- In System Type, select DualCom.
- In Connection Type, select Cellular or EASYconnect + Cell Backup.
- In SIM Number, enter the SIM number and press Get Status.
- Press Activate.
- In Account Number, enter the system’s receiver number followed by the account number.
- Select a Rate Plan for the communicator.
- Enter the panel Serial Number.
- Enter the panel Remote Key. The remote key must match the one programmed in panel REMOTE OPTIONS.
- To confirm proper communication, press Test Connection.
- A dialog pops up to ask if you want to perform the initial connection to the panel. Press Yes.
- Configure additional options as needed, then press Save.
Tech APP Activation
- Go to the Customer Summary > Systems.
- Tap the Add icon.
- Enter the System Name.
- Enter the panel Serial Number.
- In System Type, select DualCom.
- In Connection Type, choose Cellular or EASYconnect + Cell Backup.
- In Account Number, enter the system’s receiver number followed by the account number.
- Enter the panel Remote Key. The remote key must match the one programmed in panel REMOTE OPTIONS.
- Enter the SIM Number and tap Get MEID/SIM Status.
- Select a Rate Plan for the communicator.
- Configure additional options as needed, then tap Save.
PROGRAMMING
-
Before You Begin
Read this guide before you begin programming. This guide allows you to quickly learn the programming options and operational capabilities of the PowerCom. The communicator contains all of its programming information in an on-board processor and does not require an external programmer. -
Default Master Code
Universal Communicators ship with a unique four-digit default master code. This master code is generated with an algorithm that ensures it cannot be duplicated. The code can be modified or deleted in panel programming. To revert the default code to 99, use the Clear All Codes option found in the Initialization menu. Panels ship with the master code on the serial number label next to the serial number.
Getting Started
Initializing the Communicator
When programming a communicator for the first time or rewriting the entire
program of an existing communicator, use the initialization programming
option. See Initialization. Initializing clears the communicator’s memory and
sets the highest user number to user code 99.
Accessing the Programmer
To access the programmer function of the communicator:
- Connect the keypad to the programming header.
- Press and release the reset button.
- Enter 6653 (PROG). The keypad displays PROGRAMMER.
Programming Menu
The following is a list of programming menu options available in the
programming menu. Press CMD to advance through the programming menu options.
To select a menu option, press any select area when the desired menu option
displays on the keypad. Use this list to navigate to your desired programming
menu option in this guide.
- Initialization
- Communication
- Network Options
- Remote Options
- System Reports
- System Options
- Output Options
- Area Information
- Zone Information
- Stop
- Set Lockout Code
Reset Timeout
- You must enter the programmer menu within 30 minutes of resetting the communicator to avoid reset timeout. After 30 minutes, if you attempt to program by entering the 6653 (PROG) code, the keypad displays RESET PANEL. You must reset the communicator and enter the program code within the next 30 minutes.
- If you are already in the programmer menu and do not press any keys on the keypad for 30 minutes, the communicator exits programming. All data entered up to that point is saved in the communicator memory.
- To exit the programmer menu, use the stop option. The stop option is the second-to-last option in programming and disarms all areas. The programming session is terminated and the keypad returns to status list or main screen.
Special Keys
The following keys and areas are common to all DMP LCD and graphic touchscreen
keypads.
-
CMD Command
- Press CMD to advance through the programmer menu and through each step of a programming section. As you advance through the programmer menu, the keypad display any current programming already stored in the communicator memory. If no change is required for an option, press CMD to advance to the next step.
- CMD is also used to enter information into the communicator’s memory such as an IP address or a zone name. Press CMD after entering information.
-
Back Arrow
Use the back arrow to back up one step in a programming menu or to erase a typing error while entering information. -
Select Areas
The top row of keys on LCD Keypads are called select areas. The select areas on graphic touchscreen keypads are along the top of the keypad. When you need to press a select area, the keypad displays the options.
When there are more than four re sponse options avail able, press CMD to display the next set of options. Press the back arrow to return to the previous options. -
LCD Keypads
The first select area is on the far left. The second select area is second from the left. The third select area is second from the right. The fourth select area is on the far right and is for special characters. See Figure 6. -
Graphic Touchscreen Keypads
When instructed to press the first select area, touch select area 1; the second select area, touch select area 2; third select area, touch select area 3; and the fourth select area, touch select area 4. See Figure 7.
Letters and Special Characters
Use the number pad directions below to enter letters and special characters on
a number pad or use the standard keyboard directions to enter letters and
special characters on a standard keyboard.
Number Pad
- Choose a character from Table 1.
- Identify the number the character correlates with and press that number on the number pad.
- Identify the select area for that character and press that select area on the keypad. To access the lowercase letter, press that select area again.
- When the desired character displays on the keypad, return to step 1 to enter another character or press CMD if finished.
NUMBER| SELECT KEY 1| SELECT KEY 2| SELECT KEY 3|
SELECT KEY 4
---|---|---|---|---
1| A| B| C| (
2| D| E| F| )
3| G| H| I| !
4| J| K| L| ?
5| M| N| O| /
6| P| Q| R| &
7| S| T| U| @
8| V| W| X| ,
9| Y| Z| space| _
0| –| .| *| #
Table 1: Entering Letters and Special Characters in the Number Pad
Standard Keyboard
- Press ABC to access uppercase letters.
- Press abc to access lowercase letters.
- Press !@# to access symbols and special characters.
- Press 123 to access the number pad.
Note: Not all keypad prompts accept letters and/or symbols. For example, pressing P on the ENTER CODE prompt could display a 6 on the keypad.
Current Programming
Each programming option that displays shows the information already programmed
in the communicator memory. To change the already programmed information,
simply replace the information. To change a programming option that requires a
YES or NO response, press the select area for the desired response.
INITIALIZATION
- This option allows you to set the communicator’s programmed memory back to the factory defaults in preparation for system programming.
- After selecting YES to clear a section of memory, the communicator asks if you are sure you want to clear the memory. This is a safeguard against accidently erasing part of your programming. No memory is cleared from the programming until you answer YES to the confirmation prompt.
- Use YES/NO options to initialize programmable parts of the panel.
-
CLEAR ALL CODES
Choose NO to leave existing codes intact.
Choose YES to clear the user code memory and assign user code number 99 to user 20. -
CLEAR ALL SCHEDULES
Choose NO to leaves existing schedules intact.
Choose YES to clears all schedules from the programming. -
CLEAR EVENTS
Choose NO to leave existing event memory intact.
Choose YES to clear all event memory in the display events buffer. -
CLEAR ZONE PROGRAMMING
Choose NO to leave existing zone information intact.
Choose YES to set all zones in the system to UNUSED. -
CLEAR COMMUNICATION
Choose NO to leave existing communication programming intact.
Choose YES to clear communication to factory defaults. -
SET TO FACTORY DEFAULTS
Choose NO to leave the remainder of the existing communicator programming intact.
Choose YES to set the communicator programming back to factory default selections.
Note: Choosing YES does not clear the event memory, zone, user code information, or schedules.
COMMUNICATION
This option allows you to configure the communication settings for the communicator.
-
ACCOUNT NUMBER
Enter the account num ber sent to the receiver. The range is 1-65535. For account numbers of four digits or less, do not enter leading zeros. -
TRANSMISSION DELAY
Enter the number of seconds the communicator waits before sending burglary alarm reports to the receiver. The range is 15-45 seconds. The default is 0. Enter 0 to disable this function. -
COMMUNICATION TYPE
The communicator uses NET or CELL to connect with SCS-1R or SCS-VR receivers and default to NET. -
BACKUP CELL
If NET is selected as the primary communication type, BACKUP CELL will display and give you the option to enable or disable cellular backup. -
TEST TIME
Enter the time of day the communicator should send the test report to the SCS- 1R or SCS-VR receivers. Use entries between 12:00 to 11:59 and then choose AM or PM. To enable daily tests from the host panel, leave the time blank and enable test reports for receiver 1 and/or for receiver 2. See Test Report.
-
NET/CELL TEST DAYS
If you entered a test time, you can enter how often the panel test report is sent to the receiver. The range is 1 to 60 and the default is 1. Enter 0 to disable the test report. -
CHECK-IN MINUTES
Check-in reports are a method of supervising the panel for communication with the receiver. Enter the number of minutes between check-in reports. The range is 3-240 minutes. The default is 0. Enter 0 to disable check-in minutes.
Note: Additional cell charges may apply if this option is used. -
FAIL TIME MINUTES
Fail time allows the SCS-1R or SCS-VR receivers to miss a defined number of check-ins before logging that the panel is missing. For example, if cell check-in is 20 minutes and fail time is 30 minutes, the receiver only indicates a Panel Not Responding after 30 minutes. The fail time must be equal to or greater than the cell check-in minutes. If cell check-in
is 20 minutes, the fail time must be 20 minutes or more. The range is 3-240 minutes. The default is 0. -
SEND COMMUNICATION TROUBLE
- Enable communication fail notification by selecting YES at COMM TRBL. Select NO to disable. Default is YES.
- When COMM TRBLE is YES and the communicator detects a failure of communication, the communicator sends an S72 (Comm Trouble) message through a backup communication method with notification of the failure. If both primary and secondary mehtods of communication fail, then two S72 messages will be sent via the third communication method, if programmed.
- When communication is restored, the communicator sends an S73 (Comm Restored) message through the primary communication.
- If the primary or secondary communication type is CELL, S72 and S73 messages include the cell signal strength as a -dBm value.
-
BACKUP CHECK-IN MINUTES
Set the number of minutes between check-in reports for BACKUP CELL if it was enabled. The range is 3-240 minutes. The default is 0. Enter 0 to disable check-in minutes.
Note: Additional cell charges may apply if this option is used. -
BACKUP FAIL TIME MINUTES
Set the number of minutes the receiver should wait to indicate that a panel is missing using BACKUP CELL if it was enabled. If cell check-in is 20 minutes, the fail time must be 20 minutes or more. The range is 3-240 minutes. The default is 0. -
RECEIVER 1 PROGRAMMING
This option allows you to set the options for the first receiver the communicator attempts to contact when sending reports from the host panel and/or communicator. The communicator supports communication up to two receivers. -
ALARM REPORTS
Choose YES to enable Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and System Recently Armed reports to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver. -
SUPERVISORY/TROUBLE REPORTS
Choose YES to enable Supervisory, Trouble, Trouble Restoral, Force Armed, and Fault reports to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver. -
OPENING/CLOSING AND USER REPORTS
Choose YES to enable Opening/Closing, Schedule and Code Changes, and Bypass reports by user to be sent to this receiver. The default is YES.
Choose NO to disable sending these reports to the receiver.
-
TEST REPORT
Choose NO to disable sending these reports to the receiver. -
FIRST IP ADDRESS
Enter the first (primary) IP address where the communicator sends messages. Enter all 12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250. The periods display automatically. -
FIRST IP PORT
Enter the first IP port number to be used with the first IP address. The IP port identifies the port used to communicate messages with the communicator. The default IP port setting is 2001. -
SECOND IP ADDRESS
Enter the second IP address where the communicator sends messages. Enter all 12 digits and leave out the periods. The periods display automatically. -
SECOND IP PORT
Enter the second IP port number to be used with the second IP address. The IP port identifies the port used to communicate messages to and from the communicator. The default IP Port setting is 2001. -
RECEIVER 2 PROGRAMMING
Set the options for the second receiver that the communicator attempts to contact when sending reports from the host panel or communicator. The communicator supports communication with up to two receivers.
Note: If you select YES for any of the receiver 2 options, you must have at least one IP address programmed in receiver 2 programming. The receiver 2 defaults are set to NO.
-
ALARM REPORTS
Choose YES to enable Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error, and System Recently Armed reports to be sent to this receiver.
Choose NO to disable sending these reports to the receiver. The default is NO. -
SUPERVISORY/TROUBLE REPORTS
Choose YES to enable Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and Fault reports to be sent to this receiver.
Choose NO to disable sending these reports to the receiver. The default is NO. -
OPENING/CLOSING AND USER REPORTS
Choose YES to enable Opening/Closing, Schedule and Code Changes, and Bypass reports by user to be sent to this receiver.
Choose NO to disable sending these reports to the receiver. The default is NO. -
TEST REPORT
Choose YES to enable the recall test report from the host panel and/or communicator to be sent to the receiver.
Choose NO to disable sending this report to the receiver. The default is NO. -
FIRST IP ADDRESS
Enter the first (primary) IP address where the communicator sends messages. Enter all 12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250. The periods display automatically. -
FIRST IP PORT
Enter the first IP port number to be used with the first IP address. The IP port identifies the port used to communicate messages with the panel. The default IP port setting is 2001. -
SECOND IP ADDRESS
Enter the second IP address where the communicator sends messages. Enter all 12 digits and leave out the periods. The periods display automatically. -
SECOND IP PORT
Enter the second IP port number to be used with the second IP address. The IP port identifies the port used to communicate messages with the panel. The default port is 2001.
NETWORK OPTIONS
-
DHCP MODE ENABLED
Choose YES if the communicator uses a dynamic IP address. The communicator will operate in DHCP and will not use the local IP address number. The default is YES.
Choose NO to have the communicator use the IP address entered in local IP address. -
LOCAL IP ADDRESS
Enter the local IP address for the communicator. The local IP address must be unique and cannot be duplicated on the network. The default local IP address is 192.168.0.250. -
GATEWAY ADDRESS
Enter the local gateway address. The gateway IP address is needed to exit the local network. The default gateway address is 192.168.0.1. -
SUBNET MASK
Enter the local subnet mask assigned to the communicator. The default subnet mask address is 255.255.255.000. -
DNS SERVER
Enter the IP address of the DNS (Domain Name System) used by the communicator to resolve domain names into IP addresses. The default address is 0.0.0.0. -
PROGRAMMING PORT
Enter the programming port number. The programming port identifies the port used to communicate messages to and from the communicator. The default programming port setting is 2001.
REMOTE OPTIONS
This option allows you to enter the information needed for remote command/remote programming operation.
-
REMOTE KEY
Enter a code of up to eight digits for use in verifying the authority of a receiver to perform a remote command/programming session. The receiver must give the correct key to the communicator before access will be granted. All communicators are shipped from the factory with the remote key preset as blank.
To enter a new remote key, press any select area and enter any combination of up to 8 digits. The numbers you enter appear as asterisks. -
REMOTE DISARM
Choose YES to enable the communicator to be disarmed remotely. The default is YES.
Choose NO to disable remote disarming. -
APP KEY
Enter the 8-digit app key obtained in your dealer settings on Dealer Admin. This option is a security feature of the Virtual Keypad app and is used only when your dealer settings have EASYconnect set as the communication type. This option is used to eliminate the need for a static IP address programmed in network options. To enter a new App Key, press any select area and enter any combination of 8 digits. The default is blank.
SYSTEM REPORTS
This option allows you to select which reports the communicator sends to the receiver.
-
OPENING/CLOSING REPORTS
Choose NO to prevent sending opening/closing reports.
Choose YES to send opening/closing reports for each programmed area. The default is YES. -
ZONE RESTORAL REPORTS
- Specify whether the communicator sends zone restoral reports and when they will be sent.
- Choose NO to prevent sending restoral reports from the communicator.
- Choose YES to enable the communicator to send zone restoral reports when a zone restores from an alarm or trouble condition. The default is YES.
- Note: The communicator sends zone restoral reports when a zone that has restored from an alarm or trouble is disarmed. Twenty-four hour zones send rest orals immediately.
-
SEND STORED MESSAGES
If a communicator loses communication with the receiver, it will store any messages that are not able to be sent while communication was down. Selecting YES allows the communicator to send all stored messages to the receiver once communication is restored. The time at which each message was generated is also sent. Default is NO.
SYSTEM OPTIONS
This option allows you to select system wide parameters used in the operation of the communicator system.
-
ENTRY DELAY 1
Enter the entry delay time for all exit type zones programmed. When an armed exit type zone is faulted, the area must be disarmed before the entry delay expires or a fault will be detected. All burglary type zones are delayed along with the exit zone. Entry delay times range from 30-250 seconds. The default is 30 seconds. -
EXIT DELAY
Enter the exit delay time for all exit type zones. When the exit delay time starts, all activity on exit and burglary zones is ignored until the exit delay expires. During exit delay, if an exit zone trips, then restores, and trips again, the exit delay timer restarts. This restart can occur only once. Exit delay times can be from 30-250 seconds. The default is 60 seconds.
Exit Error Operation: At arming, when an entry/exit zone (EX) faults at the end of the exit delay, a zone alarm and an exit error are sent to the receiver. -
CROSS ZONE TIME
- Enter the time allowed between zone faults. When a zone programmed for cross zoning faults, the communicator begins counting down the cross zone time entered here. If the same zone or another cross-zoned zone faults within this time, an alarm report is sent to the receiver.
- If the cross zone time expires without the second zone fault, only a zone fault report from the first zone is sent to the receiver. The cross zone time can be from 4-250 seconds in one second increments. Enter 0 to disable the cross zone time feature. See Cross Zoning.
-
POWER FAIL DELAY
Enter the time allowed for a power failure to occur before sending a report. The delay time can be from 1-9 hours. When the power is off for the programmed delay time, a power failure report is sent to the receiver. For example, if the power failure delay is set for two hours, then the power failure report will be sent between 2-3 hours. Entering 0 sends the power failure report within 15 seconds. -
SWINGER BYPASS TRIPS
Enter the number of times (1-6) a zone can go into an alarm or trouble condition within one hour be fore being automatically bypassed. Bypassed zones are automatically reset when the area they are assigned to is disarmed. All 24-hour zones are reset when any area of the system is dis armed. A programming stop operation restores a bypassed zone. Entering 0 disables this function. The default is 2.- How it works
The communicator hour timer starts at 59 minutes past the hour. If the hour timer expires before the trip counter is exceeded, the trip counter returns to
- How it works
- If the trip counter is exceeded before the hour expires, the zone is
automatically bypassed by the communicator. A bypass re port is sent to the
receiver if bypass re ports is set to YES.
-
RESET SWINGER BYPASS
Choose YES to reset an automatically bypassed zone when it remains in normal condition for one hour after being bypassed. A report of the automatic reset is sent to the receiver.
Choose NO to disable automatic reset of a bypassed zone. The default is NO. -
TIME CHANGES
Choose YES to allow the communicator to request automatic time changes from the SCS-1R or SCS-VR receiver. The receiver must be programmed to send and receive time change updates from the host computer at least every 24 hours. Choose NO to disable automatic time change requests. The default is YES. -
HOURS FROM GMT
When time zone is programmed YES, enter the number (0-23) that indicates the Greenwich Mean Time zone (GMT) where the communicator is located. The default is 6. See Table 2 for GMT values.
GMT | CITY/TIME ZONE | GMT | CITY/TIME ZONE |
---|---|---|---|
0 | London, Monrovia, Lisbon | 12 | Fiji, Marshall Island, Wellington |
1 | Cape Verde Island, Azores | 13 | New Cadelonia |
2 | Mid-Atlantic | 14 | Guam, Sydney |
3 | Buenos Aires, Georgetown | 15 | Tokyo, Seoul |
4 | Atlantic Time (Canada), Caracas | 16 | Hong Kong, Singapore |
5 | Eastern Time (US, Canada) Bogota | 17 | Bangkok, Hanoi |
6 | Central Time (US, Canada) Saskatchewan | 18 | Dhaka, Almaty |
7 | Mountain Time (US, Canada), Edmonton | 19 | Islamabad, Karachi |
8 | Pacific Time (US, Canada), Tijuana | 20 | Abu Dhabi, Kazan |
9 | Alaska | 21 | Moscow, Bagdad |
10 | Hawaii | 22 | Eastern Europe |
11 | Midway Island, Samoa | 23 | Rome, Paris, Berlin |
Table 2: GMT Time Zones
CID FORMAT
Select DMP to send CID messages as Serial 3 format. Select CID to send
messages as DMP string with raw CID message appended. Refer to. Default is
DMP.
This feature requires SCS-VR Version 1.4.6 and higher or SCS-150 Version 107
and higher.
OUTPUT OPTIONS
This option allows you to program communicator output options. Switched ground (open collector) outputs are available using terminals O1 and O2 as the ground and your control panel for power. Select from outputs 1 or 2.
-
CUTOFF OUTPUTS
Define the operation of the two on-board outputs. For each programming option, enter the output you wish to activate or 0 for no output. Either or both of the outputs can be programmed here to turn off after the time specified in output cutoff time. To disable this option, press any select area to clear the display of output numbers and then press CMD. -
OUTPUT CUTOFF TIME
- If a cutoff output is assigned, you can enter a cutoff time for the output to remain on up to 15 minutes. If the output is turned off manually, the cut off time is reset. The cutoff time can be 1-15 minutes. Enter 0 to provide continuous output.
- Note: The output is cutoff within 60 seconds of the programmed cutoff time.
- The cutoff timer is shared by all outputs. If a second output trips, the timer is not reset. Both outputs turn off when the original time expires.
-
COMMUNICATION FAILURE OUTPUT
This output/favorite turns on when the communicator fails to communicate with the receiver. To turn off communication failure output, disarm the communicator. Enter 0 to disable this output. -
ARMED OUTPUT
This output/favorite turns on any time an area of the system is armed. The output turns off when the system completely disarms. Enter 0 to disable this output. -
REMOTE ARMING OUTPUT
When the system is armed or disarmed remotely from the Virtual Keypad App, VirtualKeypad.com , Remote Link, or from a schedule, this output turns on momentary for 0.75 seconds then turns off. This output can be used for panels that require a momentary short to an arming zone to arm and a momentary short to disarm.
AREA INFORMATION
This option allows you to assign functions to the area of the communicator. All non-24-hour zones must be assigned to an active area. See Zone Information for more information.
-
AREA NUMBER
Enter the number of the area you wish to program. Select from areas 1-6. -
AREA NAME
- Only those areas given names can have zones assigned to them. All others are marked
- UNUSED. See Letters and Special Characters for more information.
- To add an area name to the system, press any select area and enter up to 16 characters for the new name. Press CMD to continue. To mark an active area as unused, delete the old name by pressing any select key then press CMD. The communicator automatically sets the name as UNUSED. If you have already initialized the communicator, all areas will be marked as UNUSED.
-
AUTOMATIC ARMING
Choose YES to allow this area to arm automatically according to the opening and closing schedule. At arming, faulted zones are handled according to the option selected in bad zones. If a closing report is sent, the user number is indicated as SCH on the SCS-1R or SCS-VR receivers.
Choose NO to disable automatic arming for this area. The default is NO. -
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal condition. This option allows you to program the panel’s response to these bad zones. This option is not displayed if AUTO ARM is NO.- BYP: All bad zones are bypassed. A report of the bypass is sent to the receiver if bypass reports has been set as YES. The report indicates SCH as the user number.
- FORC: All bad zones are force armed. Zones force armed in a bad condition are capable of restoring into the system and reporting alarms if tripped. A report of the force arm is sent to the receiver. The report indicates the user number as SCH.
- REF: The automatic arming is refused and no arming takes place. Closing report is sent to the receiver.
-
AUTOMATIC DISARMING
Choose NO to disable automatic disarming by schedule for this area. The default is NO.
Choose YES to allow this area to automatically disarm according to a schedule. If an opening report is sent to the receiver, the user number is indicated as SCH.
ZONE INFORMATION
This allows you to define the operation of each protection zone used in the system.
-
ZONE NUMBER
The communicator has four zones to program. Enter the number of the zone you intend to program. To program zone 4, see Zones 1-4 Input Connection. Press CMD to enter a zone name. See Letters and Special Characters. -
ZONE NAME
Press any select area and enter up to 16 characters for the zone name. A name must be given to each zone in the system. The zone name is sent to the receiver as part of a zone event report. A zone that is not part of the system must be marked UNUSED. To mark a zone unused, delete the old name by pressing any select area, then press CMD. The programmer automatically pro grams the name as UNUSED. If you selected ZONES NO YES to clear the communicator’s memory during initialization, the zones will already be marked UNUSED. See Initialization.
-
ZONE TYPE
- The zone type defines the response of the communicator to the zone being open or short. When you assign a zone type to a zone, responses are made automatically for the zone. There are 12 zone types to choose from including Blank.
- To select a new zone type, press any select area. The display lists the four zone types shown below. When the zone type you want to select displays, press the select area below or on the name.
- Blank (–), Night (NT), Day (DY), or Exit (EX). Press CMD to display additional zone types.
- Fire (FI), Panic (PN), Emergency (EM), or Supervisory (SV). Press CMD to display additional zone types.
- Auxiliary 1 (A1), Auxiliary 2 (A2), Arming (AR), or Fire Verify (FV). Press the back arrow to display the previous zone types.
- If you select Blank, Night, Day, Exit, Auxiliary 1, or Auxiliary 2 as the zone type, the zone must be assigned to an area. See Zone 1-4 Input Connection. If you select Fire, Panic, Emergency, or Supervisory as the zone type, these are 24-hour zones that are always armed and no area assignment is needed.
-
AREA ASSIGNMENT
All non-24-hour zones are automatically assigned to area 1. Enter the area number from 1-6 where this zone is being assigned. -
ARMING ZONE ASSIGNMENT
Specify the areas to be armed by the arming type zone. Press the appropriate numbers on the keypad to assign areas 1-6. When disarmed, all areas are disarmed. -
STYLE
Specify the style for the arming/disarming operation. The default style is TGL (Toggle). Press any select area to display the style options. To view more style options, press CMD. The following is a description of the action for each option condition.- TGL (Toggle): When the zone changes from normal to shorted, the programmed areas toggle between the armed or disarmed condition. When restored to normal, no action occurs. When the zone is opened from a normal (disarmed) state, trouble is reported. When opened from a shorted (armed) state, an alarm is reported and the zone is disabled until you disarm the area(s) from either the Virtual Keypad App, VirtualKeypad.com , or Remote Link.
- ARM: When the zone is shorted, the programmed area is armed. When restored to normal, no action occurs. When the zone is opened from a normal (disarmed) state, trouble is reported. When opened from a shorted (armed) state, an alarm is reported.
- DIS (Disarm): A short will disarm the area. When restored to normal, no action occurs. When the zone is opened from a normal (disarmed) state, trouble is reported.
- STEP: A short will arm the areas. A normal condition will cause no action. An open condition will disarm the areas. When using an arming/disarming keyswitch, locate the keyswitch within the protected area.
- MNT (Maintain): When the zone is shorted, the programmed area is armed. When restored to normal, the area is disarmed and any alarm bells are silenced. When the zone is opened from a normal (disarmed) state, trouble is reported. If opened from a shorted (armed) state, an alarm is reported and the zone is disabled until you disarm the area from either the Virtual Keypad App, VirtualKeypad.com , or Remote Link.
-
NEXT ZONE
Choose YES to terminate the programming for a zone. You may enter a new zone number when ZONE NO: – appears on the display.
Choose NO to make changes to the alarm action for a zone. -
ALARM ACTION
Change the default alarm characteristics of a zone type. If you selected the non-24-hour zone type Blank, Night, Day, Exit, Auxiliary 1, or Auxiliary 2, the alarm action programming begins with Disarmed Open. If you selected the 24-hour zone type Panic, Emergency, or Supervisory, the alarm action programming begins with Armed Open. -
DISARMED OPEN
- Define the action taken by the communicator when the zone is opened while the area is disarmed. There are three actions to define: Message to Transmit, Output/Favorite Number, and Output Action.
- You must also make these selections for the Disarmed Short, Armed Open, and Armed Short zone conditions.
-
MESSAGE TO TRANSMIT
You can send two report types to the receiver: Alarm and Trouble. These are represented by the characters A and T. Press any select area to display the zone report options.- ALARM: Select A to allow an alarm report to be sent to the receiver. The zone name appears in the communicator’s alarmed zones status lists.
- TROUBLE: Select T to allow a trouble report to be sent to the receiver and the zone name to appear in the communicator’s alarmed zones status lists.
- LOCAL: Select L to prevent sending an alarm report to the receiver. The zone name appears in the communicator’s alarmed zones status lists.
- – (dash): Select – to prevent sending reports to the receiver. There is no display in the communicator’s alarmed zones status list. Only the programmed output number activates.
-
OUTPUT NUMBER
Specify an output/favorite on the communicator to activate with a zone condition. The output/favorite can be activated regardless of the report to transmit or whether or not the zone is programmed as local. An output activated by a non-24-hour armed zone is turned off when the zone’s area is disarmed by a user. To enter an output number, press any select area followed by the output number 1 or 2. -
OUTPUT ACTION
Enter an output number to display this option. This option allows you to assign an output action to the output. A description of the available output actions follows:- STD (steady): The output is turned on and remains on until the area is disarmed, an output cutoff time expires, or the output is reset from the keypad user menu.
- PLS (pulse): The output alternates one second on, one second off until the area is disarmed, an output cutoff time expires, or the output is reset from the keypad user menu.
- MOM (momentary): The output is turned on only once for one second.
- FLW (follow): The output is turned on and remains on while the zone is in off, normal, or bad condition. When the zone restores, the output is turned off.
After you have selected the message to transmit, the display prompts you for the same three selections for Disarmed Short, Armed Open, and Armed Short conditions. If the zone is a 24-hour type, only the Armed Open and Armed Short conditions are displayed. When you have programmed all of the zone conditions, the panel displays the swinger bypass selection.
-
SWINGER BYPASS
Choose YES to allow the zone to be swinger bypassed by the communicator according to the programming in swinger bypass trips and reset swinger bypass.
Choose NO to disable swinger bypassing for this zone.-
How it works
If within one hour, a zone trips the total number of times as specified in swinger bypass trips, the communicator bypasses it until the following conditions occur: -
The area in which the zone is assigned is disarmed.
-
The zone is manually reset through the bypass zones keypad user menu function.
-
The zone remains normal for one hour and reset swinger bypass is set to YES.
If the zone trips fewer than the specified times within one hour of the first trip, the bypass trip counter returns to 0 and the process must be repeated. A report of the swinger bypass is sent to the receiver if bypass reports is set to YES.
-
-
CROSS ZONE
- Choose YES to enable cross zoning for this zone. Cross zoning requires this zone to trip twice, or this zone and another cross-zoned zone to trip, within a programmed time before an alarm report is sent to the receiver. To operate correctly, all cross-zoned zones need to be programmed as the same zone type.
- When a cross-zoned zone trips, the output action assigned to the zone activates. The cross zone time specified in system options begins to count down. See Cross Zone Time. If another cross-zoned zone in the system faults, or if the first zone restores and faults again before the cross zone time expires, the bell turns on and the communicator sends an alarm report.
- If no other cross-zoned zone in the system trips before the cross zone time expires, the communicator sends only a fault report from the first zone to the receiver. If cross zone is set to yes, a valid cross zone time must be programmed for this feature.
- Choose NO to disable cross zoning for this zone. The default is NO.
-
RECEIVER ROUTING
- This option displays if zone type is set for Auxiliary 1 or Auxiliary 2. Press any select area to select the receiver routing for the selected zone.
- Select NORM to send alarm and supervisory/trouble messages from this zone to receiver 1 or receiver 2 as programmed within the receiver in communications.
- Select 1 to send alarm and supervisory/trouble messages from this zone to receiver 1 only, regardless of the programming for the receiver in communications.
- Select 2 to send alarm and supervisory/trouble from this zone to receiver 2 only, regardless of the programming for that receiver in communications.
- Select BOTH to send alarm and supervisory/trouble from this zone to both receivers, regardless of the programming for either receiver in communications.
-
ZONE NUMBER
Enter the zone number you want to program next. Return to Zone Information and follow the descriptions of each programming option. If all zones are programmed, press the back arrow at the ZONE NO display to continue.
STOP
STOP
Press any select area to exit the programmer function of the communicator.
When selected, the communicator performs an internal reset and exits the
programmer.
SET LOCKOUT CODE
SET LOCKOUT CODE
Press CMD at the stop option to display SET LOCKOUT CODE. This feature allows
you to program a special code that will be required to gain access to the
communicator’s internal programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1-5
digits long (1-65535). Do not use leading zeros for the lockout code.
-
Press any select area. The keypad displays ENTER CODE.
-
Enter a 1-5 digit code and press CMD.
Note: Do not enter a number higher than 65535. -
Enter the new lockout code you just entered in the keypad and press CMD. The keypad displays CODE CHANGED.
Once you have changed the code, it is important that you write it down and store it in a safe place. Lost lockout codes require the communicator to be sent back into DMP for repair. You may cancel a lockout code by entering 00000 at the set lockout code command option.
APPENDIX
This section provides additional zone and system information.
-
Diagnostics Function
The communicator contains a diagnostics function that allows you to test the integrity of the cellular communication and check panel settings. To use diagnostics, reset the communicator and enter the diagnostics code 2313 (DIAG). -
Communication Status
This option tests the individual components of cellular or network communication. The selected test will proceed until the first component failure or until all components have been tested with positive results. The test screen will display after each component and will be displayed for two seconds or until CMD has been pressed.
Cellular Results:
Successful Display | Failure Display |
---|---|
MODEM OPERATING | NO MODEM FOUND |
IDENTIFIED | NO SIM CARD |
TOWER DETECTED | NO TOWER |
REGISTERED | NOT REGISTERED |
This displays the cellular signal strength of the nearest tower for the SIM
card carrier.
The ▐’s represent the signal strength 0-7. Select YES to continue through the
remaining component tests. Select NO to stop testing and return to the COMM
STATUS option.
Successful Display | Failure Display |
---|---|
CONNECTED | CONNECT ERROR |
NOT ACTIVATED
COMM PATH GOOD| NO ACK RECEIVED
-
Panel Settings
Press a top row key to access the MAC address, serial number, model, and firmware version. -
Serial Number
This number is the communicator serial number. Reference this number for communicator date-of-manufacture and hardware version. Press any select area to display the serial number. -
Model Number
This menu option displays the model number of the communicator. -
Firmware Version
This menu option displays the firmware version number of the communicator and date it was released. -
Contact ID Recvd
This displays DTMF digits dialed from the control panel. -
Exiting the Diagnostics Program
Press CMD until STOP displays. Press any select area. The keypad returns to the status list display.
Using the 984 Command Function
When not in the programming menu, the function 984 + CMD can be entered at the keypad. The remote options menu appears. This menu contains the following options:
NET
The communicator allows you to perform a test on each component of the network
communication paths. While the Status List displays, enter 984 and press CMD.
The keypad display changes to NBR PICKUP NET CELL. Press the select area under
NET to allow the panel to perform a Communication Status Test.
Upon entry of a network path when prompted, the test runs and the results
display on the keypad in the order they were tested: LINK, DHCP, GATEWAY,
DEST, NET COMM.
Network Results:
Successful Display | Failure Display |
---|---|
LINK OK | LINK ERROR |
DHCP OK | DHCP ERROR |
GATEWAY FOUND | NO GATEWAY |
DEST FOUND | NO DESTINATION |
COMM PATH GOOD | NOT CONNECTED |
NO ACK RECEIVED
Note: If NET is not a communication option on the panel, NO NETWORK displays on the keypad and you are returned to the Status List.
CELL
- The communicator allows you to perform a test on each component of the cellular communication paths. While the status list displays, enter 984 and press CMD. Press the select area under CELL to allow the communicator to perform a communication status test. The keypad displays CELL IS BUSY if the modem is being tested from another keypad.
- Upon entry of a cellular path when prompted, the test runs and the results display on the keypad in the order they were tested: MODEM OPERATING, IDENTIFIED, TOWER DETECTED, REGISTERED, CONNECT SUCCESS, and CELL COM GOOD. Press CMD to advance through the results. Refer to the table in Cellular Results for more information.
Using the Walk Test
The walk test feature allows a single technician to test all zones on the system. Conduct the walk test within 30 minutes of resetting the communicator. The walk test automatically ends if no zones are tripped for 20 minutes. TEST IN PROGRESS displays at all keypads. When five minutes remain, TEST END WARNING displays. If any areas are armed, the walk test does not start and SYSTEM ARMED displays.
-
WALK TEST
To conduct the walk test, reset the communicator by momentarily pressing the reset button. From the keypad, enter 8144. The keypad displays WALK TEST. If the system
is monitored , the system sends a system test begin report to the central station. All programmed zones are included in the test. -
TRIP COUNTER FOR WALK TEST (STD)
Displays the number of zone trips during the walk test. Each time a selected zone trips, the keypad buzzes.- END – Press this select area to stop the walk test. When the walk test ends or a 20 minute timeout expires, a final sensor reset occurs. The system test end message is sent to the receiver along with verify and fail messages for each zone under test. Faulted zones display on the keypad.
- END – Press this select area to stop the walk test. When the walk test ends or a 20 minute timeout expires, a final sensor reset occurs. The system test end message is sent to the receiver along with verify and fail messages for each zone under test. Faulted zones display on the keypad.
-
TEST END WARNING
When no zones have been tripped and five minutes remain on the 20 minute walk test timer, the keypad displays TEST END WARNING and the keypad tones. If no additional test zone trips occur, the test ends and a final sensor reset automatically occurs. The system test end message is sent to the receiver along with verify and fail messages for each zone under walk test. Faulted zones display on the keypad. -
FAILED ZONES DISPLAY
Each zone that did not trip at least once during the walk test displays on the keypad that initiated the test. Any Panic (PN) or Supervisory (SV) 24-hour zone that is faulted at the end of the walk test displays a trouble condition for that zone regardless of the message programmed for the open or short condition of the zone and a zone trouble is sent to the receiver. Press CMD to display the next failed zone. -
Cross Zoning
-
Caution must be taken when cross zoning devices to ensure that the cross zone time is long enough to allow a trip of both zones before it expires. A cross zone time that is too short may allow a trip of the zones and only a zone fault report be sent to the central station.
When a cross zoned zone trips, a FAULT report is sent to the SCS-1R or SCS-VR receivers. When two cross zoned zones trip within the cross zone time, both zones send ALARM signals to the receiver. For example, if zones 1 and 2 are cross zoned zones, and only zone 1 trips, a FAULT report is sent to the receiver for zone 1. If zone 1 trips and zone 2 trips within the cross zone time, an ALARM report is sent to the receiver for zone 1 and zone 2. -
Note: To operate correctly, all cross-zone zones need to be programmed as the same zone type.
-
ADDITIONAL INFORMATION
Replace the Backup Battery
The PowerComF’s rechargeable battery provides up to 24 hours of backup battery
power when AC or DC power is not available. The battery is intended for backup
power only. It should not operate the PowerComF on a daily basis. If the
battery is low, or not plugged into the battery connector, a low battery
condition is indicated.
Replace the battery every three years. Use the steps below to remove and install a new backup battery:
- Remove the PowerComF from the backbox.
- Disconnect the battery lead connector from the PowerComF battery header.
- Remove the battery from the backbox.
- Place the new battery in the backbox and route the battery wires through the cutouts.
- Connect the new battery lead connector to the PowerComF battery header.
- Install the PowerComF on the backbox.
Note: The PowerComF is shipped with double sided tape that can be used to install the backup battery. Do not use double sided tape for listed installations.
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons.
Note
-
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. -
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
-
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
-
If necessary, the installer should consult the dealer or an experienced radio/television technician for additional suggestions. The installer may find the following booklet, prepared by the Federal Communications Commission, helpful:
“How to Identify and Resolve Radio-TV Interference Problems.”
- This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402
- Stock No. 004-000-00345-4
INDUSTRY CANADA
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
NFPA 72
This equipment should be installed in accordance with Chapter 29 of the
National Fire Alarm Code,
ANSI/NFPA 72, (National Fire Protection Association, Batterymarch Park,
Quincy, MA 02269). Printed information describing proper installation,
operation, testing, maintenance, evacuation planning, and repair service is to
be provided with this equipment.
Warning: Owner’s instruction notice, not to be removed by anyone except occupant.
Specifications
- PowerComF
- Primary Power Nominal 12 – 24 VDC
- Current Draw at 12 VDC
- Standby 75 mA
- Alarm 280 mA Peak Cellular Communication
- Dimensions and Color
- Housing Dimensions 5.50” W x 3.75” L x 1.00” H
- Housing Color Red (R)
- Ordering Information
- POWERCOMF-A Network and LTE (AT&T)
- POWERCOMF-V Network and LTE (Verizon)
- Accessories
383P Replacement Dual Band Cellular Antenna
Certifications for PowerComF
- Cellular
- FCC Part 15:
- XMR201707BG96
- XMR201910BG95M3
- IC: 10224A-201709BG96
- 10224A-2019BG95M3