SAFETY INSTRUCTIONS
This manual is an integral part of your product.
These instructions are provided for your safety. Read this manual carefully
before installing and keep it in a safe place for future reference. Select a
suitable location. Make sure you can easily insert screws and wallplugs into
the wall. Do not connect your electrical appliance until your equipment is
totally installed and controlled. The installation, electric connections and
settings must be made using best practices by a specialized and qualified
person. The power supply must be installed in a dry place. Check the product
is only used for its intended purpose.
DESCRIPTION
Content/ Dimensions
WIRING/ INSTALLING
Installing
Wiring diagram
To strike/electric lock
To gate automation
TO RESET TO FACTORY DEFAULT
- Disconnect power from the unit
- Press and hold# key whilst powering the unit back up
- On hearing two “Di” release# key, system is now back factory settings
Please note only installer data is restored, user data will not be affected.
INDICATIONS
| | |
---|---|---|---
Open the door| Bright| | DI
Stand by| Bright| | |
Press keypad| | | | DI
Operation successful| | Bright| | DI
Operation failed| | | | DI DI DI
Enter into programming mode| Bright| | |
In the programming mode| | | Bright| DI
Exit from the programming mode| Bright| | | DI
USING
Fast programming
Programming a code
Programming a badge
Door opening
-
Trigger the opening through user code
-
To trigger the opening with a badge, you only have to present the badge in front of the keypad.
Detailed Programming Guide
User Settings
To enterthe programming mode Master code
999999 is the default factory master code
To exit from the programming mode
Note that to undertake the following programming the master user must
be logged in
Setting the working mode: Set valid card only users Set valid card and PIN
users
Set valid card or PIN users
| Entry is by card only
B 1 Entry is by card and PIN together
g Entry is by either card or PIN Idefault)
To add a user in either card or PIN mode, i.e. in the mode.
IDefault setting)
To add a PIN user
| User ID number PIN The ID number is any
number between 1 & 100. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode
as follows: User ID no 1 PIN User ID no 2
I
To delete a PIN user
To change the PIN of a PIN user
!This step must be done out of programming mode)
To add a card user !Method 1) This is rds can be added continuously the fastest way to enter cards, user without exiting programming mode
ID number auto generation.
To add a card user !Method 2) This is the alternative way to enter cards using user ID Allocation. In this method a user ID is allocated to a card. Only one user ID can be
allocated to a single card.
| ****
User can be added continuously without exiting programming mode
To delete a card user by card. Note users can be deleted continuously
without exiting programming mode
To delete a card user by user ID. This
option can be used when a user has lost their card
| To add a card and PIN user in card and PIN mode I| I
To Add a card and Pin user
!The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved.)
| Add the card as for a card user Press
• to exit from the programming mode Then allocate the card a PIN as follows:
To change a PIN in card and PIN mode IMethod 1) Note that this is done outside programming mode so the user can undertake this
themselves
| ****
To change a PIN in card and PIN mode !Method 2) Note that this is done outside
programming mode so the user can undertake this
themselves
| **
To delete a Card and PIN user just delete the card|
To add and delete a card user in card mode I g**
To Add and Delete a card user| The operating is the same as adding and
deleting a card user in g
TO DELETE ALL USERS
To delete all users. Note that this is
2 0000 # a dangerous option so use with care
| ****
0000
TO UNLOCK THE DOOR
For a PIN| user Enter the PIN then press|
For a card User
For a card and PIN user
Door settings
RELAY OUTPUT DELAY TIME
To set door relay strike time ;| Master code • 0-99 is
to set the door relay time 0-99 seconds
Changing the master code
Changing the master code
| ****
The master code consists of 6 to 8 digits
---|---
For security reasons we recommand changing the master code from default.
TECHNICAL FEATURES
- Voltage: 12V DC +/-10%
- Badge reading distance: 3-6 cm
- Active current: < 60mA
- Stand-by current: 25±5mA
- Lock load output: 3A max
- Operating temperature: -45°C – 60°C
- Degree of humidity : 10% – 90% RH
- Relay output delay time
- Possible wiring connections : electric lock, gate automation, exit button
- Backlight keys
- 2000 users, supports badge, PIN, badge+ PIN
- Full programming from the keypad
- Can be used as a stand alone keypad
- The keyboard can be used to remove the lost badge number, thoroughly eliminate the hidden safety trouble
- Adjustable Door Output time, Alarm time, Door Open time
- Fast operating speed
- Lock output current short circuit protection
- Indicator light and buzzer
- Frequency: 125kHz
- Maximum transmitted power: 2,82mW
- Protection rating: IP68
WARRANTY
Warranty 2 Year
The inwice will be required as proof of purchase date. Please keep it during
the warranty period. Carefully keep the barcode and the proof of purchase,
that will be necessary to claim warranty.
WARNINGS
- Keep matches, candles and flames away from the device.
- Product functionality can be influenced by a strong electromagnetic interference.
- This equipment is intended for private consumer use only.
- Connect all the parts before switching on the power.
- Do not cause any impact on the elements as their electronics are fragile.
- When installing the product, keep the packaging out of reach of children and animals. It is a source of potential danger.
- This appliance is not a toy. It is not designed to be used by children.
- Disconnect the appliance from the main power supply before service. Do not clean the product with solvent, abrasive or corrosive substances. Dnly use a soft cloth. Do not spray anything on the appliance.
- Make sure that your appliance is properly maintained and regularly checked in order to detect any sign of wear. Do not use it if a repair or adjustment is needed. Always call on qualified personnel.
- Don’t throw batteries or out of order products with the household waste (garbage). The dangerous substances that they are likely to include may harm health or the environment. Make your retailer take back these products or use the selective collect of garbage proposed by your city.