IMPORTANT NOTE
THE HEATER OUTLET GRILLE BECOMES VERY HOT WHILST IN OPERATION. DO NOT COVER THE OUTLET GRILLE OR ANY PART OF THE APPLIANCE. FOR USE WITH 230V – 240V 50HZ ELECTRICITY SUPPLY ONLY. PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THE INSTRUCTIONS IN A SAFE PLACE.THEY WILL BE NEEDED WHEN MAINTENANCE OR SERVICING IS REQUIRED. THIS APPLIANCE MUST BE EARTHED.
BOX CONTENTS
PLEASE CHECK THAT THE FOLLOWING COMPONENTS ARE INCLUDED WITHIN THE BOX. IF ANYTHING IS MISSING OR DAMAGED, PLEASE CONTACT THE RETAILER AND DO NOT USE THE APPIANCE UNTIL YOU HAVE EVERYTHING.
- APPLIANCE WITH TRAILING LEAD WITH MOULDED 13AMP
- PLUG REMOTE CONTROLHANDSET AND BATTERIES.
- INSTRUCTION MANUAL.
- LOG SET.
- BLACK COAL.
- BLACK EMBER CRYSTALS.
HOW TO USE YOUR APPLIANCE
IMPORTANT SAFETY INFORMATION
- READ ALL OF THE INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE. INSTRUCTIONS ARE AVAILABLE ONLINE AT WWW.PAULAGNEWDESIGNS.COM
- REMOVE ALL PACKAGING AND DISPOSE OF AT AN APPROPRIATE RECYCLING FACILITY.
- DO NOT USE THIS APPLIANCE IN THE IMMEDIATE SURROUNDINGS OF A BATH, SHOWER, SWIMMING POOL OR ANY OTHER AREA WHERE THE APPLIANCE COULD COME INTO CONTACT WITH WATER OR HUMIDITY, E.G. A BATHROOM.
- DO NOT ALLOW THE APPLIANCE TO BE COVERED OR LET THE AIR INLET/OUTLET BECOME OBSTRUCTED AS THE APPLIANCE MAY OVERHEAT. PLEASE NOTE THE WARNING SYMBOL ON THE APPLIANCE. FOR INDOOR USE ONLY. THIS APPLIANCE IS NOT SUITABLE FOR USE OUTSIDE THE HOUSE
- KEEP THE POWER CORD AWAY FROM HOT SURFACES AND HOT CONDITIONS. DO NOT ROUTE THE POWER LEAD IN FRONT OF THE APPLIANCE.
- THIS APPLIANCE MUST BE INSTALLED IN A PURPOSE BUILT STUD-WORK ENCLOSURE OR A SUITABLY PREPARED FIREPLACE
- ENSURE THE APPLIANCE IS LEVEL AND THAT FURNITURE, CURTAINS ETC. ARE POSITIONED NO CLOSER THAN 1M.
- WHEN THE APPLIANCE HAS BEEN INSTALLED THE POSITION OF THE PLUG MUST BE ACCESSIBLE OR AN ISOLATION SWITCH WILL BE INSTALLED AWAY FROM THE APPLIANCE.
- WHERE THE ELECTRICITY SUPPLY CABLE HAS TO PASS THROUGH A MASONRY WALL, STONE SURROUND ETC. ENSURE SUITABLE RUBBER BUSHES ARE FITTED AT POSSIBLE WEAR POINTS.
- NEVER LEAVE CHILDREN UNSUPERVISED WITH AN UNGUARDED HEATER.
- NEVER OBSTRUCT OR COVER THE HEATER OUTLET.
- NEVER INSTALL OR USE THIS PRODUCT WHERE IT MAY COME IN CONTACT WITH WATER I.E. A BATHROOM OR WET ROOM.
- NEVER USE AEROSOLS OR STEAM CLEANERS NEAR THIS PRODUCT.
- NEVER ROUTE THE ELECTRIC CABLE NEAR THE HEATER OUTLET.
- NEVER ROUTE THE ELECTRIC CABLE UNDER CARPETS OR FLOOR COVERINGS.
- NEVER INSTALL THIS PRODUCT CLOSE TO CURTAINS OR COMBUSTIBLE MATERIALS.
- NEVER USE THE HEATER TO DRY CLOTHES OR OTHER OBJECTS.
- NEVER REMOVE THE FIREPLACE SURROUNDING WITHOUT ISOLATING THE ELECTRIC SUPPLY
- IF THE ELECTRICITY SUPPLY CABLE IS DAMAGED DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN REPLACED. FOR SAFETY REASONS THE REPLACEMENT HAS TO BE CARRIED OUT BY A SERVICE AGENT OR A SIMILARLY COMPETENT ELECTRICIAN.
- CAUTION: IN ORDER TO AVOID A HAZARD DUE TO INADVERTENT RESETTING OF THE THERMAL CUT OUT, THIS APPLIANCE MUST NOT BE SUPPLIED THROUGH AN EXTERNAL SWITCHING DEVICE, SUCH AS A TIMER, OR CONNECTED TO A CIRCUIT THAT IS REGULARLY SWITCHED ON AND OFF BY THE UTILITY
- DO NOT OPERATE THE APPLIANCE IF IT IS DAMAGED.
- REPAIRS OF ELECTRICAL APPLIANCES MUST ONLY BE PERFORMED BY AN ELECTRICAL ENGINEER. SHOULD THE APPLIANCE FAIL TO OPERATE, OR IN CASE OF ANY DAMAGE, PLEASE CONTACT THE RETAILER FROM WHOM THE APPLIANCE WAS PURCHASED.
- CAUTION: SOME PARTS OF THIS PRODUCT CAN BECOME VERY HOT AND CAUSE BURNS. PARTICULAR ATTENTION MUST BE GIVEN WHERE CHILDREN AND VULNERABLE PEOPLE ARE PRESENT.
- CHILDREN AGED FROM 3 YEARS AND LESS THAN 8 YEARS SHALL ONLY SWITCH ON/ OFF THE APPLIANCE PROVIDED THAT IT HAS BEEN PLACED OR INSTALLED IN ITS INTENDED NORMAL OPERATING POSITION AND THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN AGED FROM 3 YEARS AND LESS THAN 8 YEARS SHALL NOT PLUG IN, REGULATE AND CLEAN THE APPLIANCE OR PERFORM USER MAINTENANCE
IF YOU ARE INSTALLING YOUR APPLIANCE IN TO AN EXISTING CHIMNEY CAVITY
- ENSURE THE FLOOR AREA THE APPLIANCE WILL SIT ON IS FLAT AND FREE FROM LOOSE MATERIAL
- ENSURE THE FLUE OUT FROM THE CHIMNEY CAVITY IS SEALED
- IN ORDER TO INSTALL YOUR APPLIANCE EFFECTIVELY DISCUSS WITH YOUR SELLER THE SURROUND NEEDED TO ENCLOSE YOUR APPLIANCE INTO THE INSTALLATION LOCATION
- TO PROVIDE POWER TO THE APPLIANCE INSTRUCT A QUALIFIES ELECTRICIAN TO INSTALL AND POWER SOCKET INSIDE THE CHIMNEY CAVITY, ENSURING THERE IS AN ISOLATION SWITCH ACCESSIBLE OUTSIDE THE CAVITY
HOW TO USE YOUR APPLIANCE
APP CONNECTING INSTRUCTIONS
APP DOWNLOAD
- DOWNLOAD “ilektro” FROM THE APP STORE
- SEARCHING (ilektro fireplace) FROM THE APP STORE
- TURN ON THE BLUETOOTH FROM YOUR MOBILE DEVICE
Note: Make sure your mobile phone is well connected to the nearest 2.4GHz WIFI signal, not the 5GHz signal
LOG IN
-
OPEN THE ilektro APP, WAIT A MOMENT FOR THE ilektro APP TO INITIATE AND THEN IT WILL ASK YOU TO CREATE AN ACCOUNT OR LOG IN TO YOUR EXISTING ACCOUNT.
-
REGISTER WITH YOUR EMAIL ID OR MOBILE PHONE NUMBER AS THE USERNAME.
-
PUT ANY 6 TO 20 DIGIT NUMBERS AS PASSWORD.
-
AGREE TO THE TERMS AND CONDITIONS.
-
DURING THE PROCESS YOU MAY BE ASKED TO ALLOW THE APP TO KNOW YOUR LOCATION. THIS IS A REQUIREMENT OF THE DEVICE. THE APP WILL ONLY WORK IF YOU ALLOW THIS. THE APP DOES NOT USE THIS INFORMATION IN ANY WAY
-
YOU CAN ALSO RESET YOUR PASSWORD IN THIS INTERFACE
CONNECTING
- AIM THE REMOTE CONTROL AT THE FIREPLACE, PRESS AND HOLD THE POWER SWITCH BUTTON FOR 5
-
- SECONDS. THE FIREPLACE WILL DISPLAY “P0”.
- FIRST CONNECTION SHOULD TURN ON BLUTOOTH. DO NOT CONNECT THE PHONE TO OTHER BLUETOOTH DEVICES.
- ADD THE DEVICE BY PRESSING THE “+”. THEN ENTER THE WIFI PASSWORD FOR CONNECTING (NOTE: THE PHONE CAN ONLY CONNECT TO 2.4GHz WIFI AT THAT TIME
CONNECTING SUCCESSFULLY
THE FIREPLACE WILL DISPLAY “P4” AFTER YOUR FIREPLACE WELL CONNECTED. THE
NAME OF THE FIREPLACE APPEARS ON THE PHONE. CLICK THE NAME OF THE ELCTRIC
FIREPLACE TO ENTER THE OPERATION INTERFACE.
CONNECTING FAILURE
- PLEASE REPEAT FROM STEP 1 TO STEP 4
FUNCTIONS
LIGHT FUNCTIONS
-
YOU CAN CHANGE THE COLOUR AND BRIGHTNESS OF THE FLAME.
-
YOU CAN CHANGE THE COLOUR OF FUEL BED.
HEAT FUNCTION
- CHOOSE FOR H1: 1KW OF HEAT OR H2: 2KW OF HEAT (H0: 0KW)
TEMPERATURE FUNCTION
- YOU CAN SET THE TARGET TEMPERATURE; THE FIRE WILL AUTOMATICALLY CONTROL ITS HEATER TO WARM YOUR ROOM TO THAT TEMPERATURE AND MAINTAIN IT AROUND THAT TEMPERATURE.
YOUR APP WILL AUTOMATICALLY TAKE THE DAY AND TIME FROM YOUR PHONE OR TABLET. IF YOU ARE SETTING YOUR FIRE UP IN A DIFFERENT TIME ZONE TO THE ONE YOUR PHONE OR TABLET WAS SET UP IN, THEN FIRST SELECT “DATE & TIME” FROM THE SETTINGS MENU AND CHOOSE THE TIME ZONE YOUR FIRE IS LOCATED IN.
NOW SELECT “7-DAY PROGRAMME” FROM THE SETTINGS MENU AND PROCEED AS FOLLOWS:
a. TURN ON THE “USE 7-DAY PROGRAMME”.
b. SELECT WHETHER YOU WISH TO CONTROL THE FLAME PICTURE ONLY OR THE FLAME
PICTURE AND THE HEATING TOGETHER.
c. SELECT THE DAYS YOU WISH TO CONTROL. THERE ARE “BULK” OPTIONS OF
“WEEKDAYS”, “WEEKENDS” OR “EVERYDAY” OR YOU MAY WISH TO SET EACH DAY
SEPARATELY BY SIMPLY SELECTING THE INITIAL LETTER OF THE DAY YOU WISH TO SET.
d. NOW SET THE TIMES AT WHICH YOU WOULD LIKE YOUR FIRE TO OPERATE. ON/OFF
FOR “PERIOD 1”BY TOUCHING THE “TIME ON “AND “TIME OFF “BOXES IN TURN.
e. SET THE TARGET TEMPERATURE YOU WOULD LIKE YOUR FIRE TO HEAT THE ROOM
TO. THIS OPTION WILL NOT APPEAR IF YOU HAVE ELECTED TO CONTROL THE FLAME
PICTURE ONLY AT B ABOVE.
f. IF YOU WOULD LIKE TO CONTROL YOUR FIRE FOR A SECOND PERIOD ON THE SAME
DAY(S) THEN FOLLOW THE SAME PROCESS FOR “PERIOD 2”.
g. IT IS ESSENTIAL TO TOUCH THE “CONFIRM” BUTTON AT THE BOTTOM OF THIS
SCREEN TO SET THE PROGRAMME.
- YOU WILL NOTICE THAT ANY SCREEN YOU NAVIGATE TO ONCE YOU HAVE SET THE 7-DAY PROGRAMMER WILL HAVE THE ILLUMINATED CALENDAR ICON AT THE TOP RIGHT-HAND SIDE OF EACH SCREEN. THIS IS A QUICK REFERENCE FOR YOU TO CHECK IF YOUR FIRE HAS THE 7-DAY PROGRAMME SET OR NOT. YOU CAN TOUCH THE CALENDAR ICON TO NAVIGATE QUICKLY TO THE 7-DAY TIMER SCREEN.
- TO CANCEL THE 7-DAY PROGRAMMER, TURN OFF THE “USE 7-DAY PROGRAMME” SWITCH AND PRESS THE “CONFIRM” BUTTON. YOUR PREVIOUS SETTINGS WILL BE RETAINED IN CASE YOU WOULD LIKE TO TURN THE7-DAY PROGRAMMER BACK ON AT SOME FUTURE STAGE.
- TO REVIEW YOUR SETTINGS, RETURN TO THE 7-DAY PROGRAM ME SCREEN AND TOUCH EACH DAY IN TURN AND REVIEW THE SETTINGS FOR EACH DAY ONE-AT-A-TIME. YOU MAY REVIEW ONE DAY’S SETTING AT TIME ALLOWING YOU TO MAKE FINE ADJUSTMENTS TO EACH DAY AS YOU REQUIRE.
- IF YOU DO MAKE ADJUSTMENTS, PLEASE ENSURE THAT YOU “CONFIRM “YOUR NEW SETTINGS BEFORE EXITING THIS SCREEN.
STEP: 01
STEP: 02
STEP: 03
STEP: 04
STEP: 05
STEP: 06
STEP: 07
STEP: 08
STEP: 09
HOW TO USE YOUR APPLIANCE
**REMOTE CONTROL BUTTONS AND DISPLAY
**
-
POWER SWITCH ON/OFF THE POWER
-
FLAME BRIGHTNESS
FIVE FLAME BRIGHTNESS SETTINGS: F5-F4-F3- F2-F1 -
COLOUR OF FLAME
ORANGE, YELLOW, BLUE, ORANGE-YELLOW, YELLOW-BLUE AND YELLOW-ORANGE-BLUE -
BRIGHTNESS OF FUEL BED
FIVE FUEL BED BRIGHTNESS SETTINGS: F5-F4- F3-F2-F1, F5 IS THE BRIGHTEST, F1 TURN ON THE PULSATING FUNCTION -
FUEL BED COLOUR
TEN COLOURS OF FUEL BED SETTINGS: 01 ORANGE, 02 RED, 03 BLUE, 04 YELLOW, 05 GREEN, 06 PURPLE, 07 SKY BLUE, 08 CARMINE, 09 WHITE, 10 PINK, 11 ALL COLOUR CYCLE -
SPEED OF FLAME
3 FLAME SPEED SETTINGS : 1 LOW SPEED, 2 INTERMEDIATE SPEED, 3 HIGH SPEED -
HEATING
HO HEATING OFF, H1 LOW HEATING, H2 HEATING HIGH. INHIBITION OF HEAT FUNCTION: LONG PRESS THE HEATING BUTTON FOR 5 SECONDS, DISPLAY LO, THE PRODUCT CANNOT BE HEATED AT THIS TIME, HEATING AND TEMPERATURE SETTINGS ARE INVALID, LONG PRESS THE HOT KEY FOR 5 SECONDS OR TURN OFF THE POWER TO TURN OFF AND REMOVE THE INHIBITION OF HEAT FUNCTION. -
TIMING
POWER PFF FOR 30 MINUTES TO 8 HOURS 30-1H-2H-3H-4H-5H-6H-7H-8H-00 00 IS A TIMED SHUTDOWN -
TEMPERATURE SETTINGS
18 °, 19 °, 20 °, 21 °, 22 °, 23 °, 24 °, 25 °, 26 °, 27 °, 28 °, 29 °, 30 °, C. C IS SET FOR THE SHUTDOWN TEMPERATURE.
HOW TO USE YOUR APPLIANCE
OPERATING INSTRUCTIONS
- THERMAL SAFETY CUT OUT IF THE SAFETY CUT OUT FOR THE HEATER TRIPS THE APPLIANCE HAS OVERHEATED. IF THIS HAPPENS:
- SWITH OFF THE DEVICE FROM THE ISOLATION SWITCH AND ALLOW IT TO COOL DOWN FOR A MINIMUM OF 2 HOURS
- CHECK THE HEATER OUTLET VENTS FOR ANY OBSTRUCTION AND CLEAR IF NECESSARY. SEE MAINTENANCE SECTION FOR GUIDANCE
- PLUG IN THE APPLIANCE AND SWITCH IT ON. THE CUT OUT WILL RESET AND THE APPLIANCE SHOULD FUNCTION NORMALLY.
- IF THE APPLIANCE CONTINUES TO NOT FUNCTION CORRECTLY, CONTACT THE RETAILER OR PLACE OF PURCHASE.
THE AIR INLET GRILLES ON THE TOPSIDE AND BACK OF THE APPLIANCE SHOULD BE UNOBSTRUCTED. FREE AIR NEEDS TO CIRCULATE IN THIS AREA.
ALWAYS SWITCH OFF THE APPLIANCE FROM THE ISOLATION SWITCH BEFORE CLEANING OR UNDERTAKING AND MAINTENANCE.
GENERAL CLEANING
- ONLY CLEAN THE GLASS WHEN ITS COLD
- DO NOT USE ABRASIVE CLEANERS ON ANY PART OF THE APPLIANCE
- USE A LINT FREE CLOTH TO WIPE ANY SURFACES
- DO NOT SPRAY CLEANER INTO THE APPLIANCE
CLEANING THE FUEL BED
TO ACCESS THE FUEL EFFECT IT WILL BE NECESSARY TO REMOVE THE FRONT GLASS
VIEWING PANEL, SEE SERVICING SECTION
- ENSURE THE APPLIANCE IS SWITCHED OFF AT ISOLATION SWITCH.
- REMOVE THE LOGS AND DUST CLEAN. DO NOT WET THE LOGS.
- USE A LINT FREE DUSTER.
- LIFT ALL FUEL MEDIUM OUT OF THE FIRE AND WIPE FUEL BED DOWN.
- ENSURE NO MOISTURE REMAINS BEFORE RETURNING THE LOGS INTO POSITION. SEE LOG INSTALLATION PROCESS.
- CAUTION: REPLACE FRONT TRIM WHILE REMOVING LOGS AND FUEL MATERIAL TO ENSURE PIECES DO NOT FALL INTO THE APPLIANCE
- REPLACE THE GLASS AND TRIM AS DESCRIBED IN THE SERVICING INSTRUCTION SECTION
HOW TO USE YOUR APPLIANCE
MAINTENANCE AND CARE
CLEANING THE OUTLETS
- ENSURE THE APPLIANCE IS SWITCHED OFF AT THE ISOLATION SWITCH
- CLEAN THE AIR OUTLET GRILLES REGULARLY WITH A SOFT CLOTH OR THE NOZZLE OF A VACUUM CLEANER
FIG: 2 OUTLET
- DUST BUILD-UP CAN INHIBIT EFFICIENT PERFORMANCE OF THE FAN AND LEAD TO THE SAFETY CUT-OUT OPERATING.
- KEEP THE AREA AROUND THE APPLIANCE CLEAN AND FREE OF FLUFF, DUST OR PET HAIR.
- IN PARTICULAR, BUILD-UP OF DUST ETC. CAN OCCUR AROUND THE HEATER VENT AREA. TAKE PARTICULAR CARE TO KEEP THIS AREA FREE FROM SUCH PARTICLES ON A REGULAR BASIS TO PREVENT BUILDUP.
BATTERY REPLACEMENT
WHEN THE REMOTE BATTERIES IS LOW IT MUST BE CHANGED IMMEDIATELY. INSTALL
CORRECT REPLACEMENTS AND DISPOSE OF THE OLD BATTERIES CAREFULLY
BATTERY REPLACEMENT REMOTE CONTROL
BATTERY INFORMATION – SEE FIG. 3
- SLIDE OPEN THE BATTERY COVER ON THE BACK OF THE REMOTE CONTROL
- INSTALL AAA BATTERIES INTO THE REMOTE CONTROL
- REPLACE THE BATTERY COVER
DISCARD LEAKY BATTERIES
DISPOSE OF BATTERIES IN THE PROPER MANNER ACCORDING TO LOCAL REGULATIONS.
ANY BATTERY MAY LEAK ELECTROLYTE IF MIXED WITH A DIFFERENT BATTERY TYPE, IF
INSERTED INCORRECTLY, IF ALLTHE BATTERIES ARE NOT REPLACED AT THE SAME TIME,
IF DISPOSED OF IN A FIRE, OR IF AN ATTEMPT IS MADE TO CHARGE A BATTERY NOT
INTENDED TO BE RECHARGED.
HOW TO INSTALL YOUR APPLIANCE
TECHNICAL SPECIFICATION
MODEL | WOODLAND ELECTRIC STOVE |
---|---|
WEIGHT KG | 50 |
VOLTAGE | 220-240V AC -50-60HZ |
BATTERY HANDSET | 12V MN 21/23 |
TRANSMITTER ELECTRICAL POWER CONSUMPTION | FLAME PICTURE |
ONLY | 8W |
HEATING ON | 2000 WATT |
SUPPLY CORD | UK |
AUSTRALIAN | AS/NZS3112 |
EUROPEAN | VDE 0620 |
NOTE:
WEIGHTS UNIT ONLY NOT INCLUDING PACKAGING SUITE APPLIANCE (S) WEIGHTS ARE NOT
INCLUDING WOODEN SURROUND
THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE HAS BEEN CERTIFIED FOR USE IN COUNTRIES OTHER THAN THOSE STATED. TO INSTALL THIS APPLIANCE IN THESE COUNTRIES, IT IS ESSENTIAL TO OBTAIN THE TRANSLATED INSTRUCTIONS AND IN SOME CASES THE APPLIANCE WILL REQUIRE MODIFICATION. CONTACT YOUR RETAILER FOR FURTHER INFORMATION.
FOR PRODUCT DIMENSIONS AND INSTALLATION GUIDES FOR BUILDING YOUAPPLIANCE INTO A LOCATION, PLEASE GO TO WEBSITE: PAULAGNEW DESIGNS.COM.AU. TO DOWNLOAD THE SPEC SHEET FOR YOUR APPLIANCE
HOW TO INSTALL YOUR APPLIANCE GENERAL INSTALLATION
NOTE: INSTALLATION SHOULD BE CARRIED OUT BY A TRAINED INSTALLATION TECHNICIAN. I F THE PRODUCT IS INSTALLED INCORRECTLY YOUR WARRANTY MY BE INVALID.
IT IS VERY IMPORTANT THAT THE AIR INLET GRILLES ON THE TOPSIDE AND BACK OF THE APPLIANCE ARE UNOBSTRUCTED AND ADEQUATE SPACE IS LEFT TO ALLOW FREE CIRCULATION OF AIR AROUND THIS AREA.
TOOLS REQUIRED
HEX 3 ALLEN KEY REQUIRED UNSCREW THE SCRUB SCREW TO REMOVE THE HANDLE AND TO
OPEN THE DOOR
UNPACKING THE FIREPLACE
WARNING! DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN EXPOSED TO WATER.
IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT AND TO REPLACE ANY
PART OF THE ELECTRICAL SYSTEM IF NECESSARY.
- CAREFULLY UNPACK THE APPLIANCE. TAKE CARE NOT TO DAMAGE THE SURFACE OF THE APPLIANCE OR THE INSTALLATION AREA. KEEP PLASTIC WRAPPING AWAY FROM CHILDREN. BE RESPONSIBLE WHEN HANDLING THE PACKING MATERIALS.
- CHECK ALL PARTS AND ACCESSORIES ARE REMOVED BEFORE DISPOSING OF ANY PACKAGING.
- IF NECESSARY, KEEP THE ORIGINAL PACKAGING FOR FUTURE TRANSPORT AND/ OR STORAGE
FITTING THE APPLIANCE
TAKE CARE WHEN LIFTING THE APPLIANCE, OBTAIN ASSISTANCE IF REQUIRED AND ALWAYS
FOLLOW SAFE MANUAL HANDLING TECHNIQUES.
WHEN IN DOUBT CONSULT YOUR RETAILER OR SUITABLY QUALIFIED PERSON.
HOW TO INSTALL YOUR APPLIANCE
INSTALLATION
POSITIONING YOUR APPLIANCE
- YOUR NEW APPLIANCE MAY BE INSTALLED VIRTUALLY ANYWHERE IN YOUR HOME. HOWEVER, WHEN CHOOSING A LOCATION ENSURE THAT THE GENERAL INSTRUCTIONS ARE FOLLOWED.
- THE POSITIONING OF THE APPLIANCE SHOULD IDEALLY BE FITTED INTO/ ONTO A FLAT WALL OF BLOCK/BRICK CONSTRUCTION OR AN INTERNAL WOODEN FRAME PLASTER BOARD WALL. NO FIXINGS ARE PROVIDED WITH YOUR APPLIANCE. PLEASE SEEK ADVICE FROM YOUR RETAILER REGARDING FIXING METHODS, BASED ON YOUR CHOSEN INSTALLATION POSITION ANDYOUR WALL MATERIAL.
- ALWAYS ENSURE THE APPLIANCE IS ADEQUATELY SUPPORTED AND SITS ON A FIRM STRUCTURE WHEN MOUNTING ABOVE FLOOR LEVEL
- IF THE POWER CORD IS DAMAGED, IT MUST BE REPAIRED BY THE MANUFACTURER, ITS AUTHORIZED SERVICE CENTRE OR PROFESSIONAL PERSON.
- ENSURE THAT CURTAINS AND FURNITURE ARE NOT POSITIONED CLOSE TO THE CHOSEN POSITION, AS THIS WOULD CREATE A POTENTIAL FIRE HAZARD OR BLOCK THE HEATER OUTLET DUCTS. FOR BEST RESULTS, INSTALL OUT OF DIRECT SUNLIGHT.
- THE APPLIANCE SHOULD IDEALLY BE LOCATED CLOSE TO A SUITABLE MAINS SOCKET TO ENABLE CONNECTION. THE ELECTRICAL SOCKET MUST BE EASILY ACCESSIBLE TO ALLOW DISCONNECTION WHEN THE APPLIANCE IS FITTED.
- WARNING! IF THE ELECTRICAL SOCKET IS NOT ACCESSIBLE ONCE THE APPLIANCE HAS BEEN INSTALLED THEN A QUALIFIED ELECTRICIAN WILL NEED TO INSTALL AN ISOLATION SWITCH.
- WARNING! KEEP ANY FURNISHINGS OR COMBUSTIBLE MATERIALS AT LEAST 1m FROM THE FRONT OF THE ELECTRIC FIREPLACE.
SETTING THE FUEL BED
INCLUSIONS:
CERAMIC LOG SETS (8 PIECE LOG SET) AMBER CRYSTALS BLACK CRYSTALS COALS CHIP
FIG 5: CRYTALS AND COAL CHIPS
-
CAUTION CERAMIC LOG SETS ARE DELICATE.
TAKE CARE WHEN HANDLING. -
STEP 1
SPREAD AMBER CRYSTALS ON FUEL BED -
STEP 2
POSITION CERAMIC LOG AS PER THE DIAGRAM AS SHOWN BELOW. RANDOMLY STACK AND OVERLAY LOGS AGAINST EACH OTHER. -
STEP 3
DISTRIBUTE THE BLACK CRYSTALS EVENLY ACROSS THE FUEL BED. -
STEP 4
DISTRIBUTE THE COALS CHIPS EVENLY ACROSS THE FUEL BED
HOW TO INSTALL YOUR APPLIANCE
ELECTRICAL CONNECTION
WARNING
- ENSURE THE APPLIANCE IS FULLY ASSEMBLED AND THE FRONT GLASS WITH TRIM IS BACK IN THE APPLIANCE BEFORE THE APPLIANCE IS CONNECTED TO MAINS POWER
CONNECTING TO MAINS SUPPLY
-
CHECK WHETHER THE MAINS SUPPLY CAN ACCOMMODATE THE ADDITIONAL LOAD OF 1000 OR 2000 WATT
FIG 7: IEC POWER CABLE
-
CONNECT THE POWER CABLE TO AN EARTHED SOCKET
-
ONLY USE THE POWER CABLE PROVIDED WITH YOUR APPLIANCE AS IT WILL BE CORRECT FOR YOUR REGION
SERVICING INSTRUCTIONS
GENERAL INFORMATION
THIS APPLIANCE MUST ONLY BE SERVICED BY A SUITABLY QUALIFIED PERSON.
BEFORE UNDERTAKING ANY WORK ON THE APPLIANCE: SWITCH OFF THE APPLIANCE FROM THE ISOLATION SWITCH.
WAIT FOR AT LEAST 10 MINUTES UNTIL THE APPLIANCE HAS COOLED DOWN.
REMOTE HANDSET BATTERY REPLACEMENT THE REMOTE-CONTROL HANDSET, USES 2 X AAA BATTERIES FOR POWER OPERATION, THESE WILL NEED REPLACING OVER A PERIOD OF TIME.
FOR REPLACEMENT:
- OPEN THE BATTERY COMPARTMENT COVER ON THE REAR OF THE HANDSET.
- REMOVE THE OLD BATTERIES AND REPLACE OBSERVING THE CORRECT POLARITY (+ & -) AS MARKED UPON THE BATTERIES AND
• HANDSET REMOTE CONTROL. REPLACE THE HANDSET COVER
MAINTENANCE OF MOTORS
THE MOTORS USED ON THE FAN AND FLAME EFFECT ARE PRE-LUBRICATED FOR EXTENDED
BEARING LIFE AND REQUIRE NO FURTHER LUBRICATION. HOWEVER, PERIODIC CLEANING/
VACUUM OF THE FAN/HEATER UNIT IS RECOMMENDED.
RESETTING THE THERMAL CUT OUT SWITCH
THE APPLIANCE IS FITTED WITH AN ELECTRONIC SAFETY CONTROL (E.S.). THIS ISA
SAFETY DEVICE WHICH SWITCHES OFF THE HEAT ONLY IF, THE APPLIANCE OVERHEATS FOR
ANY REASON E.G. WHEN COVERED
IF THE HEATER STOPS OPERATING WHILST THE FLAME EFFECT CONTINUES NORMALLY, THIS INDICATES THAT THE E.S. CONTROL IS IN OPERATION.
THE E.S. CONTROL CAN ONLY BE RE-SET AFTERTHE APPLIANCE HAS COOLED DOWN
TO RE-SET THE E.S:
- SWITCH OFF THE APPLIANCE (ISOLATION SWITCH) AND LEAVE FOR UP TO 2 HOURS.
- REMOVE ANY OBSTRUCTION TO THE FAN HEATER OUTLET OR OTHER INTERNAL PARTS.
- SWITCH ON APPLIANCE AND THE E.S. CONTROL WILL RE-SET.
- ENSURE THAT THE APPLIANCE IS FUNCTIONING CORRECTLY. IF THE E.S. CONTROL OPERATES AGAIN, THE APPLIANCE SHOULD BE CHECKED BY A COMPETENT ELECTRICIAN
IF THE POWER SUPPLY IS INTERRUPTED (POWER FAILURE) OR THE APPLIANCE IS TURNED OFF AT THE ISOLATION SWITCH WHILST THE HEATER IS ON, IT WILL BE NECESSARY TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY AND LEAVE FOR 5 MINUTES IN ORDER TO DISCHARGE THE ELECTRONICS BEFORE ATTEMPTING TO TURN THE APPLIANCE ON
SERVICING INSTRUCTIONS
FAULT FINDING
OPERATE APPLIANCE BEFORE COMMISSIONING
- CLICK ON THE REMOTE HANDSET POWER BUTTON. IF THE APPLIANCE DOES NOT FUNCTION, THEN, FOLLOW POINTS 1, 2, 3, 4 AND 5 RESPECTIVELY.
- CHECK THE POWER CONNECTION AT THE ISOLATION SWITCH IS IN THE ON POSITION.
- CHECK THE ISOLATION SWITCH ON THE APPLIANCE (SEE STICKER ON THE APPLIANCE). THE SWITCH MUST BE SET TO THE “I” POSITION
- CHECK THE BATTERIES IN YOUR HANDSET. CHECK IF THE BATTERIES ARE IN THE CORRECT POSITION AND REFIT IF NECESSARY.
- IF AFTER CHECKING 1, 2, 3 & 4 NOTHING STILL HAS HAPPENED, THEN DISCONNECT THE POWER FROM THE MAINS (UNPLUG FROM SOCKET), AND WAIT FOR 60 SECONDS, THEN PLUG IT BACK IN AND REPEAT STEPS 1 TO 4. IF YOU DO NOT HAVE ACCESS TO THE MAINS SWITCH, BECAUSE IT IS BUILT-IN, THEN SWITCH OFF THE UNIT FROM ISOLATION SWITCH
FIG: 8 ISOLATION SWITCH
NOTE:
THE UNIT CAN BE OPERATED BY SUPPLIED REMOTE CONTROL ONLY. FOR THE UNIT TO
OPERATE, THE MANUAL ON/OFF SWITCH, LOCATED ON THE REAR TOP RIGHTSIDE OF THE
FIREPLACE MUST BE SWITCHED TO THE “I” POSITION.
FAULT: THE HEATING DOES NOT TURN-ON WHEN YOU SELECT HEATING MODE BUT THE FLAME EFFECT IS RUNNING.
A) CHECK THE BATTERIES IN YOUR HAND SET. THE RED LED MUST BE SHOWING BRIGHTLY.
B) TRY SELECTING HEATING MODE AGAIN, BUT CLOSER TO THE APPLIANCE.
C). TURN OFF APPLIANCE, THEN TURN IT ON AGAIN. WAIT FOR 10 SECONDS, THEN SELECT HEATING MODE AGAIN
REFERENCE INFORMATION **
**
WIRING DIAGRAM
REFERENCE INFORMATION
EXPLODED DIAGRAM
REFERENCE INFORMATION
EXPLODED DIAGRAM
Replaceable Parts
No | Description | Part Number |
---|---|---|
1 | REMOTE CONTROL | WOODLAND STOVE REMOTE |
2 | SYNCHRONOUS MOTOR | 430000210000 |
3 | MAIN PCB BOARD | 440402830125 |
4 | FUEL BED LED | 440402810100 |
5 | FLAME EFFECT ROTTISORIE | 510400300430 |
6 | FLAME LED | 440402820100 |
7 | FAN AND HEATING ELEMENT | 430400030150 |
8 | IEC CABLE | 470000070300 |
9 | ISOLATION SWITCH | 460000010400 |
10 | HANDLE SS | EL-800-308-0 |
11 | DISPLAY BOARD | 440402830001 |
12 | FUEL BED | 300400233610 |
13 | SIDE GLASS | 500400077800 |
14 | SCREEN BOARD | 300401300700 |
15 | FRONT GLASS | 500400077700 |
TERMS AND CONDITIONS WARRANTY
EUROSTOVE LTD
MENDIP INDUSTRIAL ESTATE ROOKSBRIDGE SOMERSET BS26 2UG
FULL TERMS AND CONDITIONS ARE DETAILED
IN THE WARRANTY STATEMENT ON THE WEBSITE WWW.PAULAGNEWDESIGNS.COM.AU.
IN THE EVENT OF ANY CONFLICT OF INFORMATION THE WORDING ON THE WEBSITE SHALL PREVAIL. IMPORTANT NOTE: SHOULD ANY PROBLEMS BE EXPERIENCED WITH YOUR PRODUCT, CLAIMS MUST FIRST BE SUBMITTED TO THE RETAILER WHERE THE APPLIANCE WAS PURCHASED FROM WHO WILL OFFER IMMEDIATE ASSISTANCE
REGISTRATION NUMBER:
IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2012/19/ EU, WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) MUST NOT BE DISPOSED OF WITH HOUSEHOLD WASTE. AT THE END OF ITS USEFUL LIFE PLEASE TAKE THIS PRODUCT TO AN APPROPRIATE RECYCLING CENTRE OR COLLECTION POINT. YOU CAN FIND
YOUR NEAREST RECYCLING CENTRE BY USING THE BANK LOCATOR AT
WWW.RECYCLE-MORE. CO.UK FOR UK CUSTOMERS,
WWW.ACOR.ORG.AU FOR AUSTRALIA CUSTOMERS
WWW.WEEEIRELAND.IE FOR CUSTOMERS IN THE REPUBLIC OF IRELAND, OR BY CONTACTING
YOUR LOCAL AUTHORITY
Technical support UK Distributor
Eurostove Ltd
Unit H1
Mendip Industrial Estate Rooksbridge Somerset BS26 2UG Tel:
+44(0)1934 750500
Fax: +44(0)1173 156207
technical@eurostove.co.uk
www.eurostove.co.uk
Version 1 27/10/23
Contents of manual may be updated without notice. For the latest version of
this manual please refer to our
website: www.eurostove.co.uk
References
- Home - Australian Council of Recycling
- Eurostove
- Paul Agnew Designs
- Paul Agnew Designs Australia – A leader in luxury fireplaces in Australia
- WEEE Ireland Waste Electrical and Electronic Equipment Recycling
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>