Product Information

Specifications

  • Model : SMP 2.0 with E-Gap Eductors
  • Models Available : SMP 2.0-A-EG, SMP 2.0-B-EG, SMP 2.0-C-EG
  • Certifications : ASSE, UPC, CSA certified to ASSE 1055
  • Flow Rate : 3.5 GPM eductor

Product Usage Instructions

Safety Precautions

Before operating the product, ensure to read and fully understand the user manual. Always wear protective clothing and eyewear when dispensing chemicals or working with materials. Keep all attachments secure. Observe safety and handling instructions provided by the chemical manufacturer.

Installation

  1. Mounting the unit: Use the provided mounting bracket or follow the template for proper spacing and hole locations.
  2. Drill holes: Use a 5/16 drill bit to create holes for wall anchors and install anchors securely.
  3. Fasten wall bracket: If using the bracket, secure it to the wall with screws.
  4. Unit setup: Remove the cabinet cover, insert the bottle shelf, and place the dispenser on the wall bracket or directly onto the wall.
  5. Secure unit: Install screws as per instructions to ensure proper mounting support.
  6. Reassemble: Re-install the cover on the unit.

(FAQ)

  • Q: Can the unit be used with any type of chemical?
  • A : It is recommended to follow the manufacturer’s instructions for dispensing cleaners and chemicals to ensure safe usage.
  • Q : What is the preferred orientation for installing the device?
  • A: The device should be installed vertically to ensure proper operation.
  • Q: What should I do if I don’t have a dedicated line for installation?
  • A: Ensure no cross-connections between hot and cold water are created, and follow guidelines to prevent negative effects on atmospheric vacuum breakers during installation.

safety precautions

WARNING! Read and fully understand the user manual before operating this product.

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

Please use this equipment carefully and observe all warnings and cautions.
**NOTE
WEAR| protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals, filling or emptying equipment, or changing metering tips.

ALWAYS

| observe the safety and handling instructions of the chemical manufacturer.

direct discharge away from you or other persons or into approved containers.

dispense cleaners and chemicals in accordance with the manufacturer‘s instructions. Exercise CAUTION when maintaining your equipment.

reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.

KEEP| equipment clean to maintain proper operation.
ATTACH| only to water tap outlets (25 psi Minimum, 85 psi Maximum and Maximum water temperature 120° F).

NOTE

| If the unit is used to fill a sink, the discharge hose can be placed into a sink. The unit must be mounted so that the bottom of the cabinet is above the overflow rim of the sink.

The device shall be installed in a vertical orientation.

A plumbed, dedicated lines is preferred for installation. When a dedicated line is not available, installation shall ensure that no cross-connections between hot and cold water are created and that atmospheric vacuum breakers integrated into the building water supply are not negatively affected by being under pressure for over 12 continuous hours.

introduction

Package Contents

  1. Proportioning unit – ASSE, UPC and CSA certified to ASSE 1055| 5) Hose hook — 3.5 GPM educator only
    ---|---
  2. Wall bracket| 6) Mounting hardware
  3. Bottle shelf| 7) Mounting template
  4. Discharge tube for each educator|

installation/operation

  1. The unit can be mounted with or without the provided mounting bracket. Use the mounting template for proper spacing and location of the mounting holes, noting the holes used with the bracket and holes used with dispenser back, see chart at bottom of the mounting template.
  2. Drill holes for the wall anchors with a 5/16″ drill bit. Install anchors.
  3. If using the provided wall bracket, fasten it to the wall with two screws.HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-1
  4. Remove the cabinet cover of the unit by pressing the two tabs located on the sides. Rotate up and out on the cabinet cover.
  5. Insert the bottle shelf up into the cabinet back by aligning the three top tabs on the shelf with the bottom notches on the cabinet back. Slide the shelf to the left until it’s snapped into place. The bottle shelf should be centered vertically with the unit.HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-2
  6. Place the dispenser on a wall bracket and install a screw into the cabinet back’s top centre hole. Skip to step 8
  7. If not using a wall bracket, fasten the unit to the wall using the top two mounting holes located on the cabinet back.
  8. Important: Install the screw already fastened into bottle shelf. You have an option to Install (2) more screws into holes for added mounting support.HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-3
  9. Re-install cover on the unit.
  10. Place the hose hook on the end of 3.5 GPM discharge tube. Hang on a shelf when not in use.
  11. Connect water supply hose of at least 3/8″ ID to the water inlet swivel. Min. 25 psi pressure is required for proper operation, Max. pressure 85 psi and 120°F Max. water temperature. Connect opposite end of the hose to the water supply. Turn the water supply on.HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-5
  12. Purge air from the system by pressing the buttons briefly. There may be some water discharged from the educator vents until the air is purged.
  13. Raise the handle on the unit and insert the product container onto a shelf. Lower the handle until it locks the bottle in place. Ensure bottle is aligned with the chemical seal.
  14. To operate button fill units, depress the button to dispense the product, and release the button to stop the flow. IF YOU WISH TO LOCK THE BUTTON IN THE “ON” POSITION: Depress button and slide button lock up, TO UNLOCK, DE-PRESS BUTTON AND RELEASE.HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-6
  15. To remove the product container, push the handle up until it clears the bottle.

HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-7

parts list/diagrams

HYDRO-SMP-2.0-A-EG-E-Gap-Eductors-FIG-8

Key Part No. Description
1 HYD90096402 Cabinet front
2 HYD90096464 Kit, button replacement, high flow
3 HYD90096461 Kit, button replacement, low flow
4 HYD90096439 Kit, vent seals
5 HYD90096432 Kit, bottle seal assembly
6 HYD90096433 Kit, seal replacement
7 HYD90096435 Kit, tubing replacement
8 HYD90096401 Cabinet back
9 HYD90096403 Mount bracket, vent
10 HYD90096440 Wall bracket
11 HYD90096420 Bottle shelf
12 HYD238100 Strainer washer
13 HYD90096436 Kit, water inlet assembly
14 HYD90096437 Kit, nipple assembly
15 HYD10098573 Kit, pipe plug
Key Part No. Description
--- --- ---
16 HYD10075980 Valve parts kit

a.  diaphragm

b.   armature

c.  spring

d.   valve bonnet

17| HYD10079010| Spring
18| HYD10079000| Magnet
19a

b c

| HYD90096431 HYD90096434 HYD10088870| Kit, Eductor assy 1.0 GPM (grey) Kit, Eductor assy 3.5 GPM (yellow) Kit, educator assy 3 GPM (orange)
20a


b

| HYD90097375 HYD90080288| 1.0 GPM discharge tube with flooding ring (12”)

3.5 GPM discharge tube with flooding ring (6”)

21| HYD10080730| Hose hook, dark grey
Not shown:
| HYD90096438| Kit, preventive maintenance includes: 4, 6 &7

troubleshooting

Problem Cause Solution
1. No discharge a. No water
b. Excessive water pressure b.

water running) exceeds 85 psi
| c.| Clogged water inlet strainer| c.| Disconnect the inlet water line and clean the strainer
| d.| The magnetic valve not functioning| d.| Install valve parts kit
2. No concentrate draw| a.| Low water pressure| a.| A minimum 25 psi (with water running) is required to operate the unit properly
| b.| The concentrate container is empty| b.| Replace with full container
| c.| Worn or missing concentrate bottle seal| c.| Replace seal
| d.| Discharge tube and/or flooding ring not in place| d.| Push the tube firmly onto the eductor discharge hose barb, or replace the tube if it doesn‘t have a flooding ring.
| e.| Clogged water inlet strainer| e.| Disconnect the inlet water line and clean the strainer
| f.| Poor vent seal

(#4 on parts diagram)

| f.| Replace vent seal and/or vent clips
3. Foaming in discharge| a.| Concentrate container malfunctioning| a.| Replace with new concentrate container
| b.| Worn or missing concentrate bottle seal| b.| Replace seal
| c.| Air leak in pick-up assembly| c.| Replace the pick-up assembly kit
| d.| Poor vent seal

(#4 on parts diagram)

| d.| Replace vent seal and/or vent clips
4. Failure of the unit to turn off| a.| Excessive water pressure| a.| Install regulator if water pressure (with water running) exceeds 85 psi
| b.| Magnet doesn‘t fully return| b.| Make sure the magnet moves freely Replace the spring if short of weak
| c.| Water valve parts are dirty or defective| c.| Clean or replace with valve parts kit

  • In hard water areas, the scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp the water valve and unthread the eductor. Replace in the same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the unit with the suction tube in the descaling solution. Operate the unit until the solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put the suction tube into the concentrate.

warranty

Limited Warranty
Seller warrants solely to Buyer, that the products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the Products are altered or repaired by Buyer without Seller’s prior written approval, all warranties will be void.
No other warranty, oral, expressed or implied, including any warranty of merchantability or fitness for any particular purpose, is made for these products, and all other warranties are hereby expressly excluded.
Seller’s sole obligation under this warranty will be, at Seller’s option, to repair or replace F.O.B. Seller’s facility in Cincinnati, Ohio any products found to be other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively as stated herein. Seller shall have no other liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or breach of warranty.

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYDRO User Manuals

Related Manuals