3531AG Select with Hydro Gap Air Gap Eductors User Manual
- May 15, 2024
- HYDRO
Table of Contents
**3531AG Select with Hydro Gap Air Gap Eductors User Manual
**
Safety Precautions
WARNING! Read and fully understand the user manual before operating this product.
THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS
Please use this equipment carefully and observe all warnings and cautions.
WEAR protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals, filling or emptying equipment, or changing metering tips.
ALWAYS observe safety and handling instructions of the chemical manufacturer.direct discharge away from you or other persons or into approved containers. dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise CAUTION when maintaining your equipment. reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.
KEEP equipment clean to maintain proper operation.
ATTACH only to water tap outlets (25 psi Minimum, 85 psi Maximum and Maximum water temperature 120° F).
NOTE If the unit is used to fill a sink, or the discharge hose can be
placed into a sink. The unit must be mounted so that the bottom of the cabinet
is above the overflow rim of the sink.
Device shall be installed in a vertical orientation. A plumbed, dedicated line
is preferred for installation. When a dedicated line is not available,
installation shall ensure that no cross-connections between hot and cold
water are created, and that atmospheric vaccum breakers integrated into the
building water supply are not negatively affected by being under pressure for
over 12 continuous hours.
Introduction
Package Contents
- Proportioning unit
- Supply tubing 21’ total (For Select 1+, +2), 56’ total (For Dual Select),
- Accessory kit (Mounting brackets and hardware)
- Foot valve assemblies and weights
- Metering tip kit(s) (2)
- Discharge tubing for each eductor
- Hose hook for 3.5 GPM eductor
Installation and operation
Installation
- Find suitable place close to water source for unit. Mounting bracket should be installed approx. 5’ from the floor. Level bracket and mark holes. Drill 9/32” holes and install mounting anchors and screws in bracket.
- Remove cabinet cover and hang cabinet on bracket. Mark hole for lower cabinet screw. Remove cabinet and drill 9/32” hole. Install anchor and screw in lower cabinet hole. When mounting unit, do not mount more than 5 feet from the floor. Also, never mount your concentrate container higher than the unit. Keyhole slots are also provided in the cabinet back if the mounting bracket won’t be used.
- Select metering tips (up to 4) for the selector valve. (Refer to section metering tip selection.) Push each tip firmly into a separate hose barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port being used. (This may be used for dispensing water only.) Select and install a metering tip for the single product eductor (right side) in the same manner.
- Cut tubing provided into separate supply tubes for each product to be dispensed (tubing allows 7 feet of tube per product). Supply tubes should reach from hose barbs on the selector valve body and eductor to bottom of concentrate containers Slide ceramic weights over one end of each tube and slide foot valves into the same ends of the tubes.
- Slip other end of supply tube through an opening in either side of the cabinet and push over the hose barb/metering tip on the eductor. (Repeat for all eductors.)
- Place foot valve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE STRAINERS REGULARLY FOR CLOGGING: CLEAN IF NECESSARY.
- If required, the optional Foam/Froth Reducing Tube can slide on the end of the grey 1 GPM eductor. Push the tube as far as possible. Warm the end of the tube for easy installation. This tube will reduce the amount of foam that may occur with some chemicals. It is not needed if your chemical does not foam.
- Short discharge tube is used with the 1.0 GPM eductor; minimum tube length is 7 in. (18 cm) for proper operation. Longer tubes (4 feet) are used with a 3.5 GPM eductor. Repeat for all the eductors. Hooks may be installed on longer tubes to allow discharge tube to conveniently hang from the dispenser when not in use.
- Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover.
- Connect water supply hose of at least 3/8” ID to water inlet swivel. (Minimum 25 psi pressure, with water running, is required for proper operation.) Connect opposite end of hose to water supply. Turn water supply on.
Operation
-
Purge air from the system by depressing the buttons briefly. There may be some water discharge from the eductor vents until the air is purged.
-
Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled).
Then push the button whenever dispensing is desired, and release button to stop flow of solution. If you wish to be able to lock the button in the “on” position: Depress button and slide button lock up. To unlock, depress button and release. -
It is essential that the discharge hose not be obstructed. If discharge is restricted, water will flow out the eductor vents. Do not start to operate the dispenser with liquid in the discharge tube.
-
Use for open discharge only. This dispenser is not intended to work with back pressure applied to the discharge hose.
Metering tip selection
The final concentration of the dispensed solution is related to both the size of the metering tip opening and the viscosity of the liquid being siphoned. For water-thin products, the chart at right can be used as a guideline. If product is noticeably thicker than water, consult the Measurement of Concentration procedure to achieve your desired water-to-product ratio. Because dilution can vary with water temperature and pressure, actual dilution achieved can only be ascertained by using the Measurement of Concentration procedure. The clear, undrilled tip is provided to permit drilling to size not listed should you need a dilution ratio that falls between standard tip sizes.
NOTE: A 1.0 GPM eductor is grey; a 3.5 GPM eductor is yellow.
Refer to parts diagram if unfamiliar with names of system components.
Measurement of Concentration:
You can determine the dispensed water-to-product ratio for any metering tip
size and product viscosity. All that is required is to operate the primed
dispenser for a minute or so and note two things the amount of dispensed
solution, and the amount of concentrate used in preparation of the solution
dispensed. The water-to-product ratio is then calculated as follows:
APPROXIMATE DILUTIONSAT 40 psi FOR WATER-THIN PRODUCTS (1.0 CP)
Tip Color| Orifice Size| Ratio (per Eductor Flow) 1 GPM
3.5 GPM
No Tip| .187| 2.2:1| 9:1
Grey| .128| 2.3:1| 10:1
Black| .098| 2.3:1| 11:1
Beige| .070| 3:1| 13:1
Red| .052| 4:1| 19:1
White| .043| 6:1| 25:1
Blue| .040| 7:1| 30:1
Tan| .035| 9:1| 32:1
Green| .028| 16:1| 60:1
Orange| .025| 19:1| 80:1
Brown| .023| 20:1| 85:1
Yellow| .020| 27:1| 105:1
Aqua| .018| 32:1| 128:1
Purple| .014| 64:1| 213:1
Pink| .010| 128:1| 400:1
Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn Amount of
Concentrate Drawn
Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If the test does not yield the desired ratio, choose a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact your concentrate supplier for further information on these alternative methods and the materials required to perform them.
Parts diagram
Key | Part No. | Description |
---|---|---|
1 | HYD238100 | Strainer washer |
2 | HYD10082830 | Swivel collar (molded) |
3 | HYD10082811 | Swivel stem (Molded) |
4 | HYD10075902 HYD10075903 HYD10075950 | Nipple, plastic (2 btn models) Nipple, |
platic (3 btn models) O-ring (2 required per nipple)
5| HYD10098573| Kit, Pipe plug & o-ring
6| HYD10091035| Wall bracket
7| HYD10020700 HYD10020900| Selector valve grommet back-up ring for grommet
8| HYD10098821 HYD10098824| Button, Low flow, process blue Button, High flow,
process blue
9| HYD10098544 HYD10098545| Cabinet set, select +1 Cabinet set, Dual Select
10| HYD10075980| Valve parts kit a. diaphragm b. armature c. spring d. valve
bonnet
11| HYD10079010| Spring
12| HYD10079000| Magnet
13| HYD10075995| Water valve
14a b| HYD160 HYD161| 1.0 GPM eductor – Grey 3.5 GPM eductor – Yellow
15| HYD3401R| Hose barb (included in eductor assemblies)
16| HYD690014| Metering tip kit
17| HYD10080955| Selector replacement kit e. Suction inlet, f. O-ring g.
Selector valve assembly
18| HYD500814 HYD500821| Tubing 1/4“ x 14‘ Tubing 1/4“ x 21‘
19| HYD509900| Weight
20| HYD10089410| Footvalve -Viton (EPDM also available. Order 10076302)
21| HYD10099721| Optional Foam Reduction Tube (1 GPM Only)
22| HYD10064794| 1 GPM Discharge Tube (7“)
23| HYD505804| 3.5 GPM Discharge Tube (4‘)
24| HYD10080730| Hose hook, Dark grey (Standard)
25| HYD10099707| Clip, Swivel Air-Gap Select Valve (Grey)
| Not Shown: HYD641751| Security screws (for cabinet sides)
Troubleshooting and maintenance
Problem | Cause | Solution |
---|---|---|
1. No discharge | a. No water | a. Open water supply |
b. Excessive water pressure | b. Install regulator if water pressure (with |
water running) exceeds 85 psi
c. Clogged water inlet strainer| c. Disconnect inlet water line and clean
strainer
d. Magnetic valve not functioning| d. Install valve parts kit
e. Eductor clogged| e. Clean or replace
2. No concentrate draw| a. Clogged foot valve| a. Clean or replace
b. Metering tip or eductor has scale build-up| b. Clean (descale) or replace
c. Low water pressure| c. Minimum 25 psi (with water running) required to
operate unit properly
d. Discharge tube not in place| d. Push tube firmly onto eductor discharge
hose barb
e. Concentrate container is empty| e. Replace with full container
f. Clogged water inlet strainer| f. Disconnect inlet water line and clean
strainer
g. Inlet hose barb not screwed into eductor tightly| g. Tighten, but do not
overtight
h. Air leak in pick-up tube| h. Put clamp on tube or replace tube if brittle
i. Selector out of position| i. Assure selector is in position desired
3. Excess concentrate draw| a. Metering tip not in place| a. Press correct
tip firmly into barb on eductor
b. Chemical above eductor| b. Place concentrate below eductor
4. Failure of unit to turn off| a. Water valve parts dirty or defective| a.
Clean or replace with valve parts kit
b. Magnet doesn‘t fully return| b. Make sure that magnet moves freely replace
spring if short or weak
c. Push button stuck| c. Remove button and clean cabinet/button to remove
excess dirt lodged in slide recess
5. Excess foaming in discharge| a. Air leak in pick-up tube| a. Put clamp on
tube or replace tube if brittle
6. Water discharge from air vents of eductor| a. Restricted discharge hose|
a. Be sure discharge tube is not immersed, kinked or elevated. Be sure there
is no liquid in the discharge hose when beginning to operate dispenser.
b. High water pressure| b. Install pressure regulator if flowing water
pressure exceeds 85 psi.
- In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively, a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit.
Operate the unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.
Warranty
Limited Warranty
Seller warrants solely to Buyer the products will be free from
defects in material and workmanship under normal use and service for a period
of one year from the date of completion of manufacture. This limited warranty
does not apply to (a) hoses; (b) products that have a normal life shorter than
one year; or (c) failure in performance or damage caused by chemicals,
abrasive materials, corrosion, lightning, improper voltage supply, physical
abuse, mishandling or misapplication. In the event the products are altered or
repaired by Buyer without
Seller’s prior written approval, all warranties will be void.
No other warranty, oral, expressed or implied, including any warranty of
merchantability or fitness for any particular purpose, is made for these
products, and all other warranties are hereby expressly excluded.
Seller’s sole obligation under this warranty will be, at Seller’s option, to repair or replace F.O.B. Seller’s facility in Cincinnati, Ohio any products found to be other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively as stated herein. Seller shall have no other liability, direct or indirect, of any kind, including liability for special, incidental, or consequential damages or for any other claims for damage or loss resulting from any cause whatsoever, whether based on negligence, strict liability, breach of contract or breach of warranty.
Hydro Systems
3798 Round Bottom Road
Cincinnati, OH 45244
Phone 513.271.88OO
Toll Free 8OO.543.7184
Fax 513.271.O16O
Web hydrosystemsco.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>