Product Information

Overview

This industrial USB to RS232/485/TTL isolated converter features the original FT232RL inside, providing fast communication,stability, reliability, and safety. It includes embedded protection circuits such as power isolation, ADI magnetical isolation, TVS diode, and more. The aluminium alloy enclosure ensures durability and solid performance.

Features

  • USB TO RS232, USB TO RS485, USB TO TTL (UART)
  • Original FT232RL for fast communication and better compatibility
  • Power isolation for stable isolated voltage without extra power supply
  • Magnetical isolation for signal isolation and high reliability
  • Onboard protection features for surge voltage suppression and over-current/voltage proof
  • Automatic transceiver circuit with no delay for fast and stable communication
  • TTL serial 3.3V/5V voltage translator with configurable TTL level switch
  • Aluminium alloy enclosure for durability
  • LED indicators for power and transceiver status

Specifications

  • * Product type: Industrial ADI magnetical isolation converter
    • Baudrate: 300-921600bps
    • Host port: USB
    • Device port: RS485/RS232/TTL
    • USB:
    • Operating voltage: 5V
    • Connector: USB-B
    • Protection: 200 mA self-recovery fuse, isolated output
    • Transmission distance: ~5m

Product Usage Instructions

Frequently Asked Questions (FAQ)

Overview

This is an industrial USB to RS232/485/TTL isolated converter with original FT232RL inside. It features embedded protection circuits such as power isolation, ADI magnetical isolation, and TVS diode, etc. What’s more, the USB TO RS232/485/TTL comes with an aluminium alloy enclosure, make it solid and durable to work.
The USB TO RS232/485/TTL is very easy to use, fully automatic transceiving without delay. Due to its fast communication, stability, reliability, and safety, it is an ideal choice for industrial control equipments and/or applications with high communication requirement.

Features
  • USB TO RS232, USB TO RS485, USB TO TTL (UART)
    Adopt original FT232RL, fast communicating, stable and reliable, better compatibility

  • Onboard unibody power supply isolation, provides stable isolated voltage, needs no extra power supply for the isolated terminal

  • Onboard unibody magnetical isolation, allows signal isolation, high reliability,strong anti-interference, low power consumption

  • Onboard TVS (Transient Voltage Suppressor), effectively suppress surge voltage and transient spike voltage in the circuit, lightning-proof & anti-electrostatic

  • Onboard self-recovery fuse and protection diodes, ensures the current/voltage stable outputs, provides over-current/over-voltage proof, improves shock resistance

  • Fully automatic transceiver circuit with no delay, ensures the USB port communicates with different interfaces fastly and stably, without interfering each other

  • Onboard TTL serial 3.3V/5V voltage translator, config the TTL level via switch

  • Aluminium alloy enclosure with sand blasting and anodic oxidation, CNC process opening, solid and durable

  • 3 LEDs for indicating the power and transceiver status

  • High quality USB-B and RS232 connectors, smoothly plug/pul

Specifications

  • Product type: industrial ADI magnetical isolation converter
  • Baudrate: 300-921600bps
  • Host port: USB
  • Device port: RS485/RS232/TTL
  • USB:
    • Operating voltage: 5V
    • Connector: USB-B
    • Protection: 200mA self-recovery fuse, isolated output
    • Transmission distance: ~5m
  • RS485:
    • Connector: screw terminal
    • Pins: A+, B-, GND
    • Direction control: hardware automatic control
    • Protection: 600W lightning-proof and surge-suppress, 15 KV ESD protection (reserved 120 R balancing resistor solder pads)
    • Transmission distance: ~1200m
    • Transmission mode: point-to-multipoints (up to 32 nodes, it is recommended to use repeaters for 16 nodes or more)
  • RS232:
    • Connector: DR9 male
    • Protection: TVS diode, surge protection, ESD protection
    • Transmission distance: ~15m
    • Transmission mode: point-to-point
  • TTL (UART):
    • Operating voltage: 3.3V/5V
    • Connector: screw terminal
    • Pins: TXD, RXD, GND
    • Protection: clamp protection diode, over-voltage/negative-voltage proof, shock resistance
    • Transmission mode: point-to-point
  • LED indicators:
    • PWR: red power indicator, light up when there is USB connection and voltage is detected
    • TXD: green TX indicator, light up when the USB port sends data
    • RXD: blue RX indicator, light up when the device ports send data back
  • Operating environment:
    • Temperature: -15℃ ~ 70℃
    • Humidity: 5%RH ~ 95%RH
  • Operating system: Windows 10 / 8.1 / 8 / 7 / XP

Note: There is a pad reserved for 120 R balancing resistance. Recommend you to weld 120 Ω resistors to the first and last devices if you connect many devices at the same time.

Driver Installation

  1. Connect module to PC, if you find that a yellow exclamation symbol occur as below,WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(1\)

  2. Download the driver from Waveshare Wiki
    https://www.waveshare.com/wiki/USB_TO_RS232/485/TTL#Resources

  3. After downloading, extract and install itWAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(2\)

  4. Click ExtractWAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(3\)

  5. Click Next StepWAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(4\) WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(5\)WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG- \(6\)

  6. After installing, you can check if the yellow exclamation symbol disappear.

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(7\)

Testing

INTERFACES

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(8\)

RS23 2
Connect RS232 and USB interface to PC. Open two Serial Assistance Software and set them with same baudrate, test them as below:

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(10\)

RS48 5
Connect RS485 interface to RS485 interface of target board (here we use our RS485 board to test), A to A and B to B. Open two Serial Software on PC and test it. ( Note that RS48 5 Board should pull- high RSE to send data and pull0 download it to receive))

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(11\)

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(14\)

TTL
Connect TTL interface to other UART board and connect to PC, open two Serial software and test:

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(12\)

WAVESHARE-USB-TO-RS232-Interface-Converter-Industrial-Isolation-FIG-
\(13\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

WAVESHARE User Manuals

Related Manuals