kramer EXT3-U-R USB Receiver User Guide
- May 15, 2024
- Kramer
Table of Contents
- kramer EXT3-U-R USB Receiver
- Product Information
- Product Usage Instructions
- Step 1: Check what’s in the box
- Step 2: Get to know your EXT3-U-R
- Step 3: Mount EXT3-U-R
- Step 4: Connect inputs and outputs
- Step 5: Connect power
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
kramer EXT3-U-R USB Receiver
Product Information
Specifications:
- Model: EXT3-U-R
- USB Receiver: 1
- Bracket set: 1
- Rubber feet: 4
Product Usage Instructions
Step 1: Check what’s in the box
Ensure the following items are included:
- EXT3-U-R USB Receiver
- Bracket set
- 4 Rubber feet
- Quick start guide
Step 2: Get to know your EXT3-U-R
Features
- LINK LED: Flashes blue when a link is established.
- AUDIO OUT 3.5mm Mini Jack: Connect to an unbalanced stereo audio acceptor.
- USB 2 Type A Ports (1 to 4): Connect to USB devices. Connect the receiver directly to the power adapter for USB device charging.
- ON LED: Lights green when locally powered by the adapter, orange when powered by PoC.
- LINK IN RJ-45 Connector: Connect to the LINK OUT port on the EXT3-U-T.
- PROG (Tx, Rx) 5-pin Terminal Block Connector: Connect for firmware upgrade.
- RS-232 (Rx, Tx) (with common G pin): Connect for serial extension (9600 baud rate).
- 12V DC Power Connector: Connect to the power adapter.
Step 3: Mount EXT3-U-R
Install EXT3-U-R using one of the recommended methods provided in the
manual.
Step 4: Connect inputs and outputs
Connect your devices to EXT3-U-R following the instructions provided.
Always power OFF devices before connecting them.
Wiring the RJ-45 Connectors:
This section defines the TP pinout using a straight pin-to-pin cable with
RJ-45 connectors. Ensure proper wiring as per the provided diagram.
Step 5: Connect power
The EXT3-U-R is powered via PoC. Follow safety instructions for power
connection.
FAQ
-
Q: How do I update firmware on EXT3-U-R?
A: To update firmware, connect the PROG (Tx, Rx) terminal block connector for firmware upgrade as detailed in the manual. -
Q: Can I use third-party cables with EXT3-U-R?
A: It is recommended to use Kramer cables available at www.kramerav.com/product/EXT3-U-R to avoid any potential damage. Third-party cables may not be compatible. -
Q: What baud rate is supported for RS-232 communication?
A: Only 9600 baud rate is supported for RS-232 communication with EXT3-U-R.
EXT3-U-R Quick Start Guide
This guide helps you install and use your EXT3-U-R for the first time.
Go to
www.kramerav.com/downloads/EXT3-U-R
to download the latest user manual and check if firmware upgrades are
available.
Step 1: Check what’s in the box
- EXT3-U-R USB Receiver
- 1 Bracket set
- 4 Rubber feet
- 1 Quick start guide
Step 2: Get to know your EXT3-U-R
EXT3-U-R
# | Feature | Function | |
---|---|---|---|
1 | LINK LED | Flashes blue when a link is established. | |
2 | AUDIO OUT 3.5mm Mini Jack | Connect to an unbalanced stereo audio acceptor. | |
3 | USB 2 Type A Ports (1 to 4) |
- Connect to USB devices.
- Connect the receiver directly to the power adapter in order to charge USB devices.
4| ON LED| Lights green when locally powered by the power adapter. Lights
orange when powered by PoC.
5| LINK IN RJ-45 Connector| Connect to the LINK OUT port on the EXT3-U-T.
6| PROG (Tx, Rx)| 5-pin Terminal Block Connector (with common G pin)| Connect
for firmware upgrade.
7| RS-232 (Rx, Tx)| Connect for serial extension (9600 baud rate).
8| 12V DC Power Connector| Connect to the power adapter.
Step 3: Mount EXT3-U-R
Install EXT3-U-R using one of the following methods:
-
Attach the rubber feet and place the unit on a flat surface.
-
Fasten a bracket (included) on each side of the unit and attach it to a flat surface (see www.kramerav.com/downloads/EXT3-U-R).
-
Mount the unit in a rack using the recommended rack adapter (see www.kramerav.com/product/EXT3-U-R).
-
Ensure that the environment (e.g., maximum ambient temperature & air flow) is compatible for the device.
-
Avoid uneven mechanical loading.
-
Appropriate consideration of equipment nameplate ratings should be used for avoiding overloading of the circuits.
-
Reliable earthing of rack-mounted equipment should be maintained.
-
Maximum mounting height for the device is 2 meters.
Step 4: Connect inputs and outputs
In this example EXT3-U-R is connected to the Kramer SWT3-41-U-T transmitter.
Always switch OFF the power on each device before connecting it to your
EXT3-U-R.
- Devices that are connected to the EXT3-U-R USB ports are powered/charged while connected.
- Only 9600 baud rate is supported for RS-232 communication for EXT3-U-R.
Wiring the RJ-45 Connectors
This section defines the TP pinout, using a straight pin-to-pin cable with
RJ-45 connectors.
Wiring the RJ-45 Connectors| | |
---|---|---|---
This section defines the TP pinout, using a straight pin-to-pin cable with
RJ-45 connectors.| EIA /TIA 568B|
PIN| Wire Color
1| Orange / White
| 2| Orange
| 3| Green / White
| 4| Blue
It is recommended that the cable ground shielding be connected/soldered to the
connector shield.| 5| Blue / White
6| Green
7| Brown / White
8| Brown|
To achieve specified extension distances, use the recommended Kramer cables available at www.kramerav.com/product/EXT3-U-R. Using third-party cables may cause damage!
Step 5: Connect power
EXT3-U-R is powered via POC.
Safety Instructions (See www.kramerav.com for updated safety information)
Caution
- For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
- There are no operator serviceable parts inside the unit.
Warning:
- Use only the power cord that is supplied with the unit.
- Disconnect the power and unplug the unit from the wall before installing.
References
- Kramer | Audio-Visual Solutions and Experiences
- Kramer | Audio-Visual Solutions and Experiences
- Application Diagrams - Kramer Electronics
- EXT3-U-R USB Receiver
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>