Safety Instruction
WARNING
- Disconnect all electrical devices in the water from the power supply before reaching into the water. Otherwise there is a risk of severe injuries or death by electrocution.
- This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Safety information
Electrical connection
- Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
- The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
- For your own safety, please consult a qualified electrician.
- Only connect the unit if the electrical data of the unit and the power supply match.
- Protect the plug connection from moisture.
Safe operation
- Never operate the unit if an electrical cable is defective!
- The supply cord cannot be replaced. If the cord is damaged, the appliance should be scrapped.
- Do not carry or pull the unit by its power cable.
- Route lines in such a way that they are protected from damage and do not present a tripping hazard.
- Never operate the unit if the housing is defective!
- Only open the unit housing or its attendant components if this is explicitly specified in the operating instructions.
- Only carry out work on the unit that is described in this manual.
- Never carry out technical changes to the unit.
- Only use original spare parts and accessories.
Intended use
Only use the product described in this manual as follows:
- Connection to OASE pumps with EGC connection, that are suitable for control via this device.
- While adhering to the technical specifications.
Product Description
Overview
DescriptionA
- Eco Control
- Retaining frame for fastening the device to the wall, or for fitting it to the ground stake or holding clip
- Ground stake
- Holding clip for fastening the device to the pump handle
- Operating instructions Eco Control
Properties
Eco Control can be used to control EGC-capable OASE pumps.
Features:
- Connection to the EGC socket of the pump.
- Illuminated display.
- Does not require a separate power supply.
- Control of the pump capacity, switching the Seasonal Function Control (SFC) and Dynamic Function Control (DFC) on or off, selection of programmes.
- Allows display of the pump status and malfunctions.
Installation and connection
Fastening the device to the pump
How to proceed:
B
- Fit the holding clip onto the pump handle.
- Slide the device onto the holding clip.
- Align the device.
Installing the device with the ground stake
How to proceed:
C
- Fully insert the ground stake into the ground.
- Slide the device onto the ground stake.
- Check its stability.
Fastening the device to the wall
How to proceed:
**D**
- Remove the retaining frame and fasten it to the wall using suitable screws.
- Fit the device into the retaining frame.
- Ensure that the device is properly engaged in the retaining frame.
- Ensure that the device is properly engaged in the retaining frame.
Connect the unit
NOTE
The unit will be damaged, if water enters the plug connector.
- Connect the plug connector or place the protective cap on it.
- Ensure that the rubber seal is clean and fits exactly.
- If the rubber seal is damaged, it must be replaced. When the plug connector is disconnected, the rubber seal must be replaced if it is older than 2 years.
- Always secure the plug connector or the protective cap with the two screws.
How to proceed:
**E**
- Remove the protection cap from the unit.
- Fit the plug connector and secure with the two screws (max. 2.0 Nm (max. 18 lb-in)).
- Ensure that the rubber seal is clean and fits exactly.
- Replace the rubber seal if damaged.
- Only connect the plug to the left-hand EGC socket.
Operation
Control system overview
| Description| Function
---|---|---
1| Two-line display with backlighting|
2| LED ON/OFF| Indicates whether the pump is switched on or off.
3| ON/OFF button| For switching the pump on or off.
4| Arrow keys| For changing values in the menus or selecting other lines in
the menu.
5| Mode button| For selecting the next menu in the display. The selection is
continuous. It continues from the last menu to the first menu.
6| LED MODE| Indicates the pump status.
Status displays
The LEDs signal the following statuses:
LED | Status | Description |
---|---|---|
LED ON/OFF | Green | The pump is switched on. |
Off | The pump is switched off. | |
LED MODE | Green | Seasonal Function Control (SFC) and/or Dynamic Function |
Control (DFC) is activated
Red flashing| Malfunction (→ Error messages)
Off| SFC and/or DFC is deactivated
Menu: AquaMax Eco Expert / AquaMax Eco Titanium pump
Menus and setting options when connecting a pump AquaMax Eco Expert.
Description
-
Connected pump (e.g. AquaMax Eco Expert 21000)
-
The pump is switched off
Setting: -
Switch on the pump via the ON/OFF button
-
Connected pump (e.g. AquaMax Eco Expert 21000)
-
The pump is switched on
Operating modes: -
SPEED
: The speed is shown as a percentage (SFC is deactivated) -
SFC MODE
: SFC is activated (it is not possible to adjust the speed)
− SFC mode (MIN, MID, MAX)
Adjustment (only forSPEED
): -
Change the speed using the arrow keys
−0 %
: Min. speed,100 %
: Max. speed
Display only -
SFC
(Seasonal Flow Control)
− ON
: Activated
− OFF
: Deactivated -
SFC-MoDE
(MIN, MID, MAX)- SFC deactivated: No display
-
Select the next display using the arrow keys
Display only -
Current power consumption of the pump in watts
- Display precision: ±5 % of max. pump capacity
-
Current speed of the pump in rpm
-
Select next/previous display using the arrow keys
Display only -
Total pump operating time in hours
-
Pump serial number
-
SFC is switched on
Setting: -
Switch off SFC using the arrow key
-
SFC is switched off
Setting: -
Switch on SFC using the arrow key
Menu: Aquarius Eco Expert pump
Menus and setting options when connecting a pump Aquarius Eco Expert.
Description
-
Connected pump (e.g. Aquarius 28000)
-
The pump is switched off
Setting: -
Switch on the pump via the ON/OFF button
-
Connected pump (e.g. Aquarius 28000)
-
The pump is switched on
Operating modes: -
SPEED
: The speed is shown as a percentage (DFC is deactivated) -
DFC MODE
: DFC is activated (it is not possible to adjust the speed)- DFC mode (SCENE 1 … SCENE 12)
Adjustment (only forSPEED
):
- DFC mode (SCENE 1 … SCENE 12)
-
Change the speed using the arrow keys
− 0 %:
Min. speed,100 %:
Max. speed
Display only -
DFC
(Seasonal Flow Control)ON
: ActivatedOFF
: Deactivated
-
DFC-MODE
(SCENE 1 … SCENE 12)- DFC deactivated: No display
-
Select the next display using the arrow keys
Display only -
Current power consumption of the pump in watts
- Display precision: ±5 % of max. pump capacity
-
Current speed of the pump in rpm
-
Select next/previous display using the arrow keys
Display only -
Total pump operating time in hours
-
Pump serial number
-
DFC is switched off
Setting: -
Switch on DFC
-
DFC is switched on, program 1 is selected
Setting: -
Program selection (SCENE 1 … SCENE 12) and switching DFC off using the SET DFC –› SCENE 12 arrow keys
Storage/winter protection
The unit is frost-proof to -20 °C. If lower temperatures are expected, remove the unit and place it in storage.
- Protect the EGC plug from moisture and dirt.
Error messages
Once a malfunction has been corrected, the error message automatically disappears.
Error message | Cause | Remedy |
---|---|---|
WARNING NO WATER |
The pump has run dry (dry run protection has tripped). |
- Flood the pump.
- Fully submerge the pump for operation in a pond.
- Vent the supply line.
- Remove any blockage from the supply line.
Filter housing clogged (dry run protection has tripped).| Clean pump
WARNING``MOTOR BLOCKED
| Impeller unit is blocked (dry run protection has
tripped).| Disconnect the power supply and remove obstacle. Then switch the
pump on again.
WARNING``HIGH TEMPERATURE
| Ambient temperature for dry installation is too
high.|
- Avoid exposure to direct sunlight.
- Note maximum water temperature of +35°C.
Water temperature too high.| Note maximum water temperature of +35°C.
WARNING``HIGH POWER
| Current consumption too high
- Impeller unit running sluggishly
- Excessively soiled water
| Clean the pump.
Wear parts
- EGC plug seal
Disposal
NOTE
Do not dispose of this unit with household waste.
- Dispose of the unit by using the return system provided for this purpose.
- Should you have questions, please contact your local disposal company. They will give you information on how to correctly dispose of the unit.
- Render the unit unusable by cutting the cables.
Power consumption| Connection /interface| Length of connection – cable|
Dimensions| Weight
---|---|---|---|---
| | |
---|---|---|---
Dust protected. Splash water protected| Protect from direct sun radiation.| Do
not dispose of together with household waste!| Read the operating instructions
Description
Pos. | Eco Control |
---|---|
1 | 11710 |
2 | 20284 |
3 | 40466 |
4 | 40465 |
Customer Support
OASE GmbH
Tecklenburger Straße 161 48477 Hörstel | Germany
+49 (0) 5454 80-0
+49 (0) 5454 80-9353
info@oase.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>