RDINSCOS MT28 Pinless Moisture Meter
Product Information
Specifications:
- Intended Use: Measure moisture content in various materials without damaging the surface
- Technical Parameters: Advanced sensor technology, measurement range: 5% – 50%, Accuracy: ±2%
- Product Features: Pinless design, easy-to-read display, battery level indicator
Product Description:
The Pinless Moisture Meter is a precision tool designed to accurately measure
moisture content in a wide range of materials without the need for pins. It
features advanced sensor technology that provides reliable readings without
damaging the surface being tested.
Product Usage Instructions
Safety Instructions:
Before starting or using the device, carefully read the manual provided. Store
the manual near the device for reference.
Operation:
- Insert batteries according to the specified orientation.
- Switch on the device using the power button.
- Hold the device close to the material being tested and press the measurement button to start the reading.
Application Notices:
Avoid using the device in potentially explosive environments or exposing it to
corrosive chemicals or liquids. Operate the device in dry conditions within
specified humidity and temperature ranges.
Transportation and Storage:
During transportation, ensure the device is securely packed to prevent damage.
Store the device in a dry and cool place away from direct sunlight.
Maintenance and Repair:
Regularly clean the device with a soft, dry cloth. Do not attempt to repair
the device yourself; seek assistance from an authorized specialist company if
needed.
Waste Disposal:
Dispose of the device and its components following local waste disposal
regulations.
FAQ:
-
Q: Can the Pinless Moisture Meter be used on all types of materials?
A: The meter is suitable for use on various materials such as wood, drywall, and plaster, but may not be suitable for all material types. Refer to the user manual for specific guidance. -
Q: How often should the batteries be replaced?
A: Battery replacement frequency depends on usage. Replace the batteries when the low battery indicator appears on the display.
Safety instructions
Read this manual carefully before starting or using the device. Always store the manual near the device or its site of use.
Warning
Read all safety warnings and all instructions. Failure to follow the warnings
and instructions may result in electric shock, fire or serious injury.
- Do not use the device in potentially explosive rooms or areas and do not install it there.
- Do not expose device to harmful or corrosive chemicals.
- Do not immerse the device in water. Do not allow liquids to penetrate into the device.
- The device may only be used in dry surroundings and must not be used in the rain or at a relative humidity exceeding the operating conditions. Protect the device from permanent direct sunlight. Do not expose the device to strong vibrations. Do not operate the device near medical equipment (e.g. pacemakers).
- Do not open the device.
- Do not operate the device near open electrical wiring.
- Risk of suffocation. Do not leave the packaging lying around. Children may use it as a dangerous toy.
- The device is not a toy and does not belong in the hands of children.
Warning of electrical voltage
- There is a risk of a shot circuit due to liquid penetrating the housing. Do not immerse the device and accessories in water.
- Work on the electrical components must only be carried out by an authorised specialist company.
Product description and specifications
Intended use
This device is used for non-destructive determination of the material moisture
approximately in 2 types of wood and 2 types of building materials, it based
on the principle that the dielectric permittivity of the measured material
changes with the change of moisture content, the moisture content of the
measured material is deduced from the changed dielectric permittivity. This
device reading data is displayed as %, it is based on the dry mass of the
measured material. The moisture content is calculated according to the
following formula: moisture content in % = (mass of water contained in the
material / dry mass of the material)x 100. Example: 1 kg of material
containing 500 g of water = 100% material moisture.
The measured values may differ from the actual values. Measured values can be
influenced by many factors, such as, building materials of the same type but
with
different designation/composition/strength/ density. If different measured
values occur, the reading should be viewed as relative value, can still be
used to compare the measurement at this spot with another spot.
Technical parameters
Product Features
Display description
Battery level indicator
Operation
-
Insert battery
Open the battery compartment, and insert a 9V battery. Correct polarity must be observed. -
Switching On/off
Press the on/off button “ ****” to switch on/off the device. When the device is switched on again, the last selected measuring mode is preset in the device.
The device will switch itself off Automatically to conserve battery life after 5 mins without operation. -
Start measurement
- Selecting the measurement mode
For optimum measuring results, measurement mode must be selected according to the material characteristic before each measurement. This instrument has 4 selectable measurement mode. Before making a measurement, press the button “ “, ” “, “ “,” “to select the appropriate material.
Reference tables of materials
**Reference table of moisture level**
- For wall&masonry measurement mode, the reading should be viewed as relative value.
- Wallpaper affects the measurement to such an extent that the displayed value is falsified. Nevertheless, the reading can still be used to compare the measurement at this spot with another spot. The same is true of tiles, linoleum, vinyl and wood used to cover building materials.
- Influenced by the surface treatments (e.g. paints), such wood measurements should only be viewed relatively.
Hold data
- Selecting the measurement mode
-
Turn on/off the flashlight
In order to work in dark environments, this device is equipped with LED flashlight. Press the flashlight on/off button “ ****” to turn on or turn off. -
Replace battery
Battery replace is required when the device can no longer be switched on or the battery icon shows low power “ ****“. Please remove the old battery, then observe the polarity mark in the battery compartment , and install new batteries according to the correct polarity. -
Zero calibration
Zero calibration is suitable for special reasons that the instrument cannot reset its reading to “00.0%” without measuring any materials.
Application notices
Special notices
- There must be no metal inside the measuring material.
- The pinless moisture meter readings can be influenced by nearby metal, or your own fingers. Keep at least 5cm distance from metal. Keep fingers in the narrower part of the bottom when using, well clear of sensor.
- Do not use this instrument measure water or water attached to the surface of the material that has not yet been immersed in the material, it is pointless. Because this pinless moisture meter is not an instrument which can detect the presence of water molecules, but works according to the principle that the dielectric constant of the material changes with the change of humidity.
- Wipe measured material surface dry and neat for best results. In addition, the measured material (walls, masonry and wood) being measured is not stacked or sitting on wetter materials.
- The pinless moisture meter is penetrates up to 0.75inches deep, so wetter materials located below your subject material can also influence the readings, as can metal nails, workbench, your hand, etc.
- To accurately measure the moisture content of the material to be tested, it is recommended that the thickness of the material to be tested ≥5mm, otherwise, the measurement value will be too low.
- If the thickness of the material to be tested is less than 19mm, due to the Max induction depth of the instrument is 19mm, in order to avoid interference from other materials, it is recommended to suspend or stack the material above 19mm before measurement.
- Make sure that the sensor make good contact with the material with no air inclusions.
- Always measure at several different spots.
This pinless moisture meter is a sensitive tool. This means that the measurement results may be subject to slight deviations when someone touches the device with their hand or when contact is broken between the device and the material being measured. However, contact with the user’s hand forms the basis for calibrating the measuring device, so we recommend holding onto the device whilst taking your measurements.
Other factors that may affect the readings
- If possible, do not measure wood with a temperature below -5°C. Too low wood temperatures distort the result of the measurement.
- Avoid static charge of the material to be measured due to friction. Static charge distorts the measurement result.
- If a construction material contains electrically conducting substances, the dielectric constant is also increased, which then simulates high moisture values. Consequently, a too high measured value will be displayed.
- With a wood moisture of less than 10 % RH electrostatic forces may occur at the good to be measured. This can falsify the result of the measurement. Experience has shown that this occurs at the outlet of veneer drying plants. Remove the static charge by use of suitable grounding measures.
- From visual inspection it is not always apparent.whether there are any electrically conducting substances inside the construction material. Some of the main error sources here are in particular reinforcements, metal laminations and conducting insulation such as slag in timber beam ceiling constructions. Especially in case of insulation materials with metal lamination, measured values are often misinterpreted.
- For optimum conditions neither electrical fields nor conducting materials should be present.
- Oily and/or aqueous timber preservatives affect the measurement result.
- The surface of the material to be measured should be as level as possible to permit thorough contact of the measuring probe.
Transportation and storage
lf you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.
-
Transport
For transporting the device use a suitable bag to protect it from external influences. -
Storage
When the device is not being used, observe the following storage conditions:- Dry and protected from frost and heat.
- Protected from dust and direct sunlight.
- The storage temperature complies with the values specified in the technical data.
Maintenance and repair
-
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners. But only clean water to moisten the cloth. -
Repair
Do not modify the device or install any spare parts. For repairsor device testing, contact the manufacturer.
Waste disposal
Always dispose of packaging materials, batteries and waste electrical and electronic equipment in an environmentally friendly manner and in accordance with the applicable local disposal regulations.
This icon is taken from Directive 2012/19/EU. It states that this device must not be disposed of with household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
Feel free to contact us: rotin@reddragonmeter.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>