RDINSCOS RD630 3 In 1 Electromagnetic Electric Magnetic Radio Frequency Field Detector User Manual

May 15, 2024
RDINSCOS

RDINSCOS logo EMF Detector
user’s manual

RDINSCOS RD630 3 In 1 Electromagnetic Electric Magnetic Radio Frequency
Field Detector Feel free to contact us:
rotin@reddragonmeter.com

Product Overview

1.1 foreword
Thank you for purchasing this EMF detector. It is a precision hand-held electronic instrument with built-in electromagnetic radiation sensors. The signals received by the sensors are processed by integrated circuits and displayed in digital form on the screen.
Users can reasonably process or effectively avoid electromagnetic radiation based on the detection results. In order to exert the best function of the instrument, please read this manual carefully before using It.

1.2 Application Scenario
This instrument can detect electromagnetic radiation conditions in the living environment, and plays an important role in reasonable processing or effective avoidance of electromagnetic radiation. It can be applied to the following scenarios:

  1. Used for measuring EMF in living environments such as living rooms, offices, computer rooms, power distribution rooms, and emission towers, such as testing the intensity of electromagnetic radiation in frequently active areas such as sofas, restaurants, bedrooms, and desks. If the radiation exceeds the standard, use an instrument to identify the radiation source and move it to a safe location; Test the electromagnetic radiation intensity of the base station on the roof of the community.
  2. Used for functional testing of EMF protection products, such as testing whether the electromagnetic protective clothing and computer radiation screen shield electromagnetic radiation functions are qualified; Monitoring of radio frequency signals in confidential rooms or shielded machine rooms.
  3. Used for testing various radio frequency electromagnetic radiation, such as testing the electromagnetic radiation of wireless communication equipment such as mobile phones, radios, routers, microwave ovens, and radio frequency transmitting equipment; Demonstrate the relative strength of various electromagnetic wave radiation sources.

Product diagram

2.1 Product Component DescriptionRDINSCOS RD630 3 In 1 Electromagnetic
Electric Magnetic Radio Frequency Field Detector - Product
Diagram

  1. display screen
  2. Indicator light: green represents safety, yellow represents warning, red represents exceeding
  3. Unit switch/Automatic power off button (short press switch units, long press turn on or off APO)
  4. Hold screen/MAX mode button (Short press hold screen, long press switch to MAX mode)
  5. Power & buzzer on/off button (Short press Power on /off, long press buzzer on/off)
  6. Battery compartment

2.2 Display Description

  1. Mute icon: This icon is displayed on the screen, indicating that the buzzer has been turned off
  2. Electric field radiation value
  3. Electric field radiation unit: V/m
  4. Magnetic field radiation value
  5. Magnetic field radiation unit: mG/μ T( short Press the “ ” key to switch)
  6. RF radiation value
  7. RF radiation unit:mW/ m²
  8. Radiation safety assessment: safe; warning; Exceed
  9. Battery indicator icon
  10. Automatic power off icon, if this icon is displayed, it indicates that the instrument will automatically power off
  11. MAX mode icon, if this icon is displayed, it indicates that the current detection mode is the MAX mode, the instrument only displays the maximum value during this detection process
  12. Lock screen icon, if this icon is displayed, it indicates that the screen is locked

Instrument use

3.1 Power On/Off

In the power off state, short press the “ ” key to turn on
In the power on state, short press the “ ” key to turn off

3.2 Electric field radiation detection
After power on, the instrument automatically enters the detection state, and slowly moves the head of the instrument closer to the measured object. The closer it is to the measured object, the greater the electric field radiation intensity. When the electric field  radiation value displayed on the screen is greater than 80V/m, The red indicator lights up, the radiation evaluation icon displays “ “, and the buzzer sounds “beep…”, it indicates that the electric field radiation here exceeds the standard.

RDINSCOS RD630 3 In 1 Electromagnetic Electric Magnetic Radio Frequency
Field Detector - Field radiation

3.3 Magnetic field radiation detection
After power on, the instrument automatically enters the detection state, and slowly moves the head of the instrument closer to the measured object. The closer it is to the measured object, the greater the magnetic field radiation intensity.When the magnetic field radiation value displayed on the screen is greater than 8mG or 0. 8uT, The red indicator lights up, the radiation evaluation icon displays “ “, and the buzzer sounds “beep…”, itindicates that the magnetic field radiation here exceeds the standard.

RDINSCOS RD630 3 In 1 Electromagnetic Electric Magnetic Radio Frequency
Field Detector - Field radiation 2

3.4 Radio frequency(RF) radiation detection
After power on, the instrument automatically enters the detection state, and slowly moves the head of the instrument closer to the measured object. The closer it is to the measured object, the greater the RF radiation intensity.When the RF radiation value displayed on the screen is greater than 10mW/m², The red indicator lights up, the radiation evaluation icon displays “ ” and the buzzer sounds “beep…”, it indicates that the magnetic field radiation here exceeds the standard.

RDINSCOS RD630 3 In 1 Electromagnetic Electric Magnetic Radio Frequency
Field Detector - Field radiation 3

NOTE:
In the three radiation assessments of EF, MF, and RF, as long as one of the radiation assessments reaches “ “, the instrument will illuminate a yellow indicator light, and the buzzer will emit an alarm sound; Similarly, as long as one radiation assessment reaches “ “, the instrument will illuminate a red indicator light anda buzzer will sound an alarm.

3.5 Replace the battery
When the battery icon on the display shows low “ ” please replace the battery immediately.

3.6 Switch Units
The magnetic field radiation intensity of this instrument has two units: mG and uT, the user can switch according to their needs, please set it according to this method: short press the “ ” key to observe the unit change on the display.

3.7 Cancel automatic power off
This instrument will automatic power off by default, if you need to cancel, set it according to this method: press and hold the “ ” key, until the icon “APO” on the screen disappears.

3.8 Switch MAX mode
The instrument defaults to real-time measurement mode every time it is turned on, if you need to switch the MAX mode, please press and hold the “ ” key until the icon “MAX” appears on the screen and release the button.

3.9 Additional Notes

  1. The microwave signal has high frequency, short wavelength, poor penetration ability and strong reflection ability. For example, when detecting the radiation of mobile phone base stations, there is a big difference between outdoor and indoor with walls; If there is a metal object near the detection point, the microwave will likely have the effect of enhanced reflection, so make sure that there is no metal or other conductor near the detection point to avoid incorrect detection results.
  2. Washing machines, refrigerators, air conditioners, rice cookers, computer hosts, and other electrical appliances that have a metal shell and do not generate strong electric field radiation in the circuit will be well shielded and eliminated when the grounding wire of the power socket is good. If such appliances detect large electric field radiation, users need to carefully check whether the power socket is well grounded. “Another type of household appliances, such as microwave ovens, induction cookers, energy-saving lamps, old-fashioned television displays, humidifiers, negative ion air purifiers, and laser printers, have relatively large electric field radiation even if they are connected toa ground wire. This is because there are electronic circuits that generate high voltage and strong electric fields inside such appliances, and grounding shielding cannot completely eliminate the effect. Therefore, reasonable precautions should be taken to avoid such appliances.”
  3. Most radiocommunication related devices emit high- frequency signals, such as mobile phones, walkie- talkies, wireless telephones, radio and television towers, and wireless network devices. This type of device typically transmits signals intermittently or the power level of the transmitted signal varies. For example, when the phone is in standby mode, it only receives signals; The transmission power of the mobile phone base station will automatically adjust according to network load, weather conditions, etc. There is alsoa class of wireless communication devices that do not transmit but only receive signals, such as satellite television ground receiving antennas, which do not emit radiation. Users should first understand the relevant working conditions of the radiation source to avoid confusion about the detection results.
  4. Itis necessary to hold the instrument for testing, as the detection value of the instrument is based on the handheld calibration condition. After approaching the test object, stabilize the position and do not move quickly, because the instrument requires reaction time.
  5. The detection sensor of the instrument is located at the front of the housing and has a high detection sensitivity. During detection, you should hold the back of the instrument (below the screen and buttons) by hand. Do not shield or touch the front end of the instrument and the display screen with your hands or other conductors to avoid introducing interference from the induced electric field caused by the human body or conductors.

technical parameter

sensitivity| EF: 1V/m
MF: 0.1mG or 0. 01uT
RF: O. 01mW/m²
---|---
measuring range| EF: 1-1999V/m
MF: 0.1-999.9mG or 0.01-99.99uT
RF: 0.01-19.99mW/m²
Alarm threshold| | EF(V/m)| MF(mG)| RF(mW/m2)
Safe| <40| <4| <5
Alert| 40 ∼ 80| 4 ∼ 8| 5 ∼ 10
Avoid| >80| >8| >10
measuremet accuracy| ±5%
bandwidth| 50Hz-3500MHz
APO| Default 15 minutes, can be turned off
Operating temperature and humidity| temperature: -10 ∼ +60°C ; humidity:<80%RH
battery| 1 9V Battery
size| 147
68. 5*28mm
weight| about 132g