This 6-to-2 (six-2-two) RF switch designed for SCR operations. Version MK2 have got higher colletion and new hazard protecton board. There is still Fint- Win switching and added BCD inputs Unused ANT ports are connected to ground. Switch can handle more than 3 kW of the RF power. Do not forget to Hat Switch Protection

Jump to

Applications
Switch ControlConnection
BCD control examples
Parameters
Product details

Applications

  • SO2R antenna switch (2 TRX to 6 ANT)
  • BPF switch for 2 TRX
  • 6 TRX to 2 antennas

version with PL SO-239 connectors

version with N connectors

Example for 2 TRX and 6 antennas

Example for Band Pass Filters switching for 2 TRX
6-to-2 RF SWITCH BPF switching example

Switch Control – Connection

  • It is possible to use connectors A – IN 1-6, B – IN 1-6 for conventional control over 2×6 wires (+ GND). The switch is controlled by + DC voltage > 12 V
  • You can also use the BCD inputs A – BCD IN and B – BCD IN
  • The switch uses binary combinations for 1 to 6. Again + DC voltage
  • The BCD control has a voltage range from 3 V to 15 V. It is therefore compatible with TTL logic
  • If you use TTL logic, it is necessary to connect also voltage for relay control – terminal +12 at BCD. The recommended voltage is 13.8 V. It is possible to supply this voltage separately for the A and B part. If the jumper (+12V A/B | AB) is switched to the A/B position, each half of the switch needs its own voltage (+12V at BCD). In this case, the part not in use may be without power. In the AB position, only one power supply to one of the +12 at the BCD connector is needed.
  • If the BCD control voltage is higher than +13 V (13 to 15 V DC), you can use only the BCD + GND wires. The voltage for the relay is derived from the BCD control voltage.

Control connectors

BCD control examples

The control voltage can range from 3 to 15 V. In case it is lower than 12 V, the power supply for relay control (+12 V) must be connected. You need 5 wires for one TRX. If the BCD voltage is higher than 13 V, no additional voltage needs to be connected. 4 wires are needed (for each TRX). If you are using a long control cable, you can use the > 12 V control BCD voltage and also connect > 12 V to the +12 V connector.

When you use device with Open Collector:

  • You have to add Pull Up resistors 4k7, 0.25 W from + 12 V DC (12-15 V)
  • Or smaller 1k when you use + 5 V for Pull Ups

Parameters

A – 1 VSWR

B – 4 VSWR

B – 6 VSWR

A – B no selected

A – 2, B – 1

A – 4, B – 1

Product details

Included in package
Switch assembled and tested
Mounting holder with bracket – image

Box dimensions (mm) 222x145x75 – al box IP65
Weight brutto (kg) 2.75 kg

Manufacturer:
Ing. Jan Šustr
ID 05476356, VAT CZ8407024780
Palachova 1777/7, 591 01  Czech republic, Europe

General instructions:
Please also read general instructions before handling the product

European Union Declaration of Conformity

Manufacturer Ing. Jan Šustr (QRO.cz):
ID 05476356, VAT CZ8407024780
Palachova 1777/7, 591 01 Žďár nad Sázavou, Czech republic, Europe
declares that the assembled product

6-2 SWITCH MK2 CLASSIC

is compatible with the relevant Union harmonisation legislation directives:
EMC Directive 2014/30/EU ČSN EN 61000-6-3 ed. 2 ČSN EN 61000-6-1 ed. 2 (333432)

On behalf of Ing. Jan Šustr (QRO.cz)
Ing. Jan Šustr, CEO
1st January 2023

Tag: manual, switch, antenna switch, 6-2, 6 to 2, classic

Previous article

RELATED PRODUCTS

Easy Controller manual

Easy controller manual

Antenna switch 6-to-1 manual

Easy Controller 5-2

6-to-2 antenna switch MIG CLASSIC

6-to-1 antenna switch

LEAVE A COMMENT

agree to the Terms and Conditions and the Privacy Policy
Post comment
2021-2023 hamparts shop All Rights Reserved. Designed by Lucine Terms and Conditions Privacy Policy Cookies EU COCOR platform Cookies settings

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals