Gude ZWP 280-30 PTO Pump Instruction Manual

June 4, 2024
Gude

Gude logo Translation of the original instructionsGude ZWP 280 30 PTO
Pump
ZWP 280-30 93913
GÜDE GmbH & Co. KG

Birkichstrasse 6
74549 Wolpertshausen
Deutschland

ZWP 280-30 PTO Pump

Please read the instructions carefully before starting the machine.

Scope of deliveryGude ZWP 280 30 PTO Pump - fig

Assembly

Cleaning & Transport, Gude ZWP 280 30 PTO Pump - fig
1Gude ZWP 280 30 PTO Pump - fig 2

Gude ZWP 280 30 PTO Pump - fig 3Gude ZWP 280 30
PTO Pump - fig 4

Technical data

PTO pump ZWP 280-30
Item no. 93913
Max. discharge rate 16.800 l/h
Max. discharge head 30 m
Max. submersion depth 5 m
Max. particle size 2 mm
Max. water temperature Connection 35 °C
Connection 1 1/2” IT
Weight 19,5 kg

Use the machine only after you have carefully read and understood the operating instructions. Familiarise yourself with the operating elements and the proper use of the machine. Observe all safety instructions contained in these operating instructions. Act responsibly towards other people. The operator is responsible for accidents or hazards affecting third parties. If there is any doubt about connecting and operating the machine, contact customer service. Cleaning and user maintenance may not be carried out by unsupervised children. Children should be supervised to make sure they do not play with the device. Instruct children and unauthorized persons to keep away from the appliance at all times.

Intended use
The pump is intended solely for draining and pumping out containers in the house, garden, farm, and agriculture and is only designed for use with water, taking into account the technical data and safety instructions.
This machine may only be used as directed. The manufacturer cannot be held responsible for any damage resulting from non-compliance with the provisions of the generally applicable regulations and the provisions of these operating instructions.
Do not use the pump when the outdoor temperature is below 0 °C or above 40 °C.

The pump is not suitable for long-term operation (e.g. as a circulating pump in ponds or for brooks). If this type of operation is carried out, the service life will be reduced accordingly. Make sure there are sufficient breaks between operating cycles.
The pump must not be used for pumping wastewater.
**** The pump must never be used as a circulation pump in swimming pools.

Safety instructions

While the pump is in operation, persons or animals are not allowed to be standing in or immersed in the liquid to be pumped (e.g. swimming pools, cellars, etc.). The temperature of the liquid to be pumped must not exceed +35 °C.
The pump must never run dry. Never operate the pump when it is left unsupervised in order to prevent damage caused by any possible malfunctions.
If the pump is used in pools, wells, etc., and in the corresponding water systems, the standards for pump use in the relevant country must be observed.
The user is responsible for third parties for the use of the pump (water system, etc.). Do not under any circumstances carry out repairs yourself.

Requirements for the operator
The operator must have carefully read and understood the operating instructions before using the machine.
Qualification: Apart from detailed instruction by a competent person, no special qualification for using the machine is required.
Minimum age: The machine may only be operated by persons who are 16 years of age or older. An exception is made for use by a minor if the pump is used in the course of vocational training to acquire the skill under the supervision of a trainer.
Training: The only requirement for using the machine is appropriate instruction by a qualified person or the operating instructions. Special training is not necessary.

In case of emergency
Initiate the first aid measures necessary for the injury and request qualified medical assistance as soon as possible. Safeguard the injured person from further injury and keep them calm.
If you request help, please provide the following information: 1. Location of the accident, 2. Type of accident, 3. A number of injured persons, 4.
Type of Injuries

SYMBOLS

**** WARNING/CAUTION!
**** WARNING – to reduce the risk of injury, read the operating

instructions.
| Standing in the medium to be pumped is prohibited
| Beware of hand injuries!
| Keep your distance!

Maintenance

The machine must not be used if it is damaged or if the safety devices are defective. Replace worn and damaged parts. Repairs and work not described in this manual should only be carried out by qualified personnel. Only use original accessories and original spare parts. Only a regularly serviced and well-maintained machine can be a useful tool. Lack of maintenance and care can lead to unforeseeable accidents and injuries.
We recommend regularly rinsing the pump with clean water to prolong the service life of the pump seals.
Caution! Depending on the design, water that is left standing for a longer period of time may cause corrosion in the pump housing!
(Brown coloration) For winter storage, ensure that there is no water in the device. Otherwise, frost exposure may cause irreparable damage to the device. The pump must be stored in a completely empty and frost-proof state. If required, you can find the spare parts list online at www.guede.com.

Warranty
The warranty period is 12 months for commercial use, 24 months for consumers, and begins with the date of purchase of the machine. The warranty exclusively covers defects attrib- table to material or manufacturing defects. In the event of the assertion of a defect within the meaning of the warranty, the original proof of

GÜDE accepts no liability for damages caused by incorrect installation or operation of the pump.
The system must be regularly inspected and checked to ensure that it is in perfect condition.
Please note that, in accordance with the valid standards, we do not accept any responsibility for any damage caused by our devices if the following have occurred
Inappropriate repairs carried out by unauthorized service centers;

  • Misuse or non-compliance with the intended use;
  • Overloading of the pump through continuous operation;
  • Frost damage and other damage caused by weather;

The same applies to the accessories.
In order to avoid or prevent potential damage (e.g. flooded rooms, etc.) as a result of an improper pump operation (due to malfunctions or defects), the owner (user) must take appropriate safety measures (installation of an alarm device, reserve pump, or similar).

Important customer information
Please note that returns within or outside the warranty period should always be in the original packaging. This measure effectively avoids unnecessary transport damage and any resulting disputed settlement. Your equipment is optimally protected only in the original box, and keeping it in that box will ensure smooth processing.

Service

Do you have a technical question? A complaint? Do you need spare parts or operating instructions? We can help you quickly and easily in the Service section of the homepage of Güde GmbH & Co. KG (www.guede.com). Please help us to help you. To identify your machine in the event of a complaint, we need the serial number, the item number and year of manufacture. All this data can be found on the rating plate.

Tel.: +49 (0) 79 04 / 700-360
Fax: +49 (0) 79 04 / 700-51999
Email: support@ts.guede.com

Inspection and maintenance schedule

Time interval Description Further details, if applicable
According to need and level of soiling Clean and rinse

Fault – Cause – Remedy

Fault Cause Remedy
Pump does not suck The pump impeller is clogged Remove blockage
Insufficient water flow rate Dirty suction filter

Water level drops rapidly
Maximum discharge head exceeded
Kink in the discharge line| Clean the suction filter
Ensure sufficient afterglow
Check the length of the discharge line
Check the discharge line

GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
Email: info@guede.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>