AKOYU ZD51 Amhey Bike Alarm Instruction Manual

May 15, 2024
AKOYU

AKOYU ZD51 Amhey Bike Alarm

ZD51-Amhey-Bike-Alarm-PRODUCT

INSTALLING & CHANGING

INSTALLING & CHANGING THE ALARM BATTERIES

  • Open the bottom cover of the alarm, and install 3 pcs AAA alkaline batteries, the red light flashes with the sound of “D” and will automatically start, and use the alarm directly.
    • Step 1: Remove the bottom of the alarm a screw
    • Step 2: Use the disassembly piece to reach into the bottom of the opening slot and rotate a little to open the bottom
    • Step 3: from the side up in turn, according to the buckle position to pry open the bottom shell side

ALARM INITIAL STATE:

  • The product is initially set to the disarmed state of the alarm mode, and the remote control has been paired.
  • The volume is 3 levels 120BD, and the sensitivity is 7 levels.
  • After installation, press the alarm button of the remote control and wait for 5s to use it. Installation Method

INSTALLATION METHOD

HOW TO SET THE FUNCTION

HOW TO SET THE FUNCTION OF THE ALARM DEVICE

  • Connect the battery to power on, and the red light flashes with the sound of “DI” will automatically start.
  • Battery installed and ready for use. Take out the battery will shut down automatically.
  • According to the remote control button, you can disarm, arm, adjust the volume, and find a bicycle in the parking.
  • Press the sound-switching button on the remote control to select the appropriate volume.
  • Mute+flash light – Medium+flash light – medium-120db – 120db+flash light.
  • Press the arm or disarm button on the remote control to select the alarm state.

SET THE ALARM MODE

  • Press the disarm button on the remote control to set it to the disarm state.
  • Press the grey mode button on the front of the alarm to switch the state. alarm mode- flash light mode-LED always on mode.

HOW TO SET THE VIBRATION SENSOR SENSITIVITY

  • When the device is in the disarm state, press the disarm key and arm key at the same time to enter the vibration sensitivity adjustment state.
  • Press the arm key to increase vibration sensitivity.
  • Press the SOS button to decrease (a total of seven adjustable levels, press the switch volume button and emergency button at the same time to exit the sensitivity setting mode).

SET THE TOILET ALARM

Operation method: device disarm, select an installation angle (placed horizontally, for example), short press the mode key to the always-on light mode, then long press the mode key, a drop indicates the opening of the tilt alarm function; then short press the mode key to exit the normal light mode, alarm mode, when the device is tilted from the current angle greater than 45°, the device begins to drop the alarm, if the tilt angle has been greater than 45°, every 30S Alarm once; when the tilt angle is less than 45°, the alarm stops.

  1. short press the setting key to switch to the disarm state
  2. Short press the mode key to switch to always on light mode
  3. Long press the mode button “drop” to open the tilt alarm
  4. The alarm starts when the tilt angle of the device is greater than 45°

OPERATION METHOD

CLOSE THE TILT ALARM OPERATION METHOD:

Equipment disarm, short press the mode key to the always-on light mode, then press and hold the mode key, two ticks to close the tilt alarm function.

  1. short press the setting key to switch to the disarm state
  2. Short press the mode key to switch to always on light mode
  3. Long press the mode key “drop” two sounds to close the tilt alarm function

HOW TO RESET THE DEVICE

Remove the battery, press and hold the mode key, access the battery power on, the red light is long and slow rhythm “drop” ten sounds, and finally fast “drop drop drop drop” that the total clear success, clear all accessories and settings, the default alarm mode disarm state
Learn Remote Control

Operation method: In alarm mode, press and hold the setting key, the device will tick and the light will be on to indicate the pairing state, then trigger any button of the remote control, the device will “tick” two times to indicate successful learning; “tick” one time to indicate repetition; “tick” three times to indicate full learning;

  1. Short press the mode key to switch to alarm mode
  2. Long press the setup button to enter the remote control pairing status
  3. Trigger any button on the remote control to send a pairing signal

Remove Remote Control

  • In the pairing state, long press the setting key, and the host “drops” 5 times to delete all the remote controls (pairing state short press any key or long time without any operation will exit the pairing state
  • Note: The host can learn up to 20 remote controls, when the host is in constant light or flashing light mode, triggering any key of the remote control will switch the host to alarm mode.
  1. short press the setting key to switch to the disarm statel
  2. long press the setting key, enter pairing status

LOW BATTERY WARNING: When the voltage is lower than 3.3V there will be a “drip drip drip” sound, the interval of 30-35 seconds will alarm 1 time

Technical parameters

  • Working voltage: 3 pcs AAA alkaline batteries
  • Standby power   consumption: < 1 ma
  • Alarm power consumption: <50ma
  • Wireless distance: >100m
  • Wireless frequency: 433.92MHz
  • Alarm decibel: 120db
  • If you have any questions, Please contact After-sales mailbox:Amheyserve@outlook.com.