Shadow Industrial 903689 Shadow Infinity Industrial Infrared Heater Instruction Manual

May 15, 2024
SHADOW Industrial

Shadow Industrial 903689 Shadow Infinity Industrial Infrared Heater

Shadow-Industrial-903689-Shadow-Infinity-Industrial-Infrared-Heater-
product

Specifications

  • Model : Shadow Infinity 9kW and 12kW Industrial Infrared Heaters
  • Technology: Ultra Low Glare infrared lamp technology
  • Mounting Options : Wall, ceiling, or chains
  • Intended Use : Heating large-sized industrial spaces

Product Information

The Shadow Infinity industrial and warehouse infrared heaters feature market- leading Ultra Low Glare infrared lamp technology combined with advanced outer casing construction. This design allows for instant short-wave infrared heat in the desired area. These heaters are available in 9kW and 12kW models and are suitable for heating large industrial spaces.

Safety Instructions

Before using the heater, carefully read all provided instructions. The heater must be installed and used as instructed to ensure safe operation. Failure to follow instructions may result in injury or damage to property.

Cleaning & Maintenance

Any maintenance or repairs should only be carried out by a qualified electrician if you’re unsure how to do so. Refer to online resources for further guidance on cleaning and maintaining the heater.

Assembly Instructions

Wall Mounting

  1. Mark and drill 4 holes, each 10mm in diameter on the wall.
  2. Insert 4 expansion bolts into the holes, align the heater onto the bolts, and lock with 4 nuts tightly.

Bracket Mounting

Refer to the diagram for the minimum safe mounting distances between the appliance and the ceiling, wall, and floor.

FAQ

  • Can the Shadow Infinity heaters be used outdoors?
    • No, these heaters are designed for indoor use in industrial spaces.
  • What is the recommended voltage for these heaters?
    • The heaters operate at 240V.

Brief Introduction

Shadow Infinity industrial and warehouse infrared heaters combine the market- leading Ultra Low Glare infrared lamp technology with advanced outer casing construction, allowing you to achieve instant short-wave infrared heat in the desired area.

The Shadow Infinity 9kW and 12kW Industrial Heaters can be mounted from a wall or ceiling or hung on chains and are designed for heating large-sized industrial spaces.

Important Information

Please carefully read all instructions provided before using this appliance. This heater must be installed and used as instructed.

This Operation Manual contains important safety information, as well as some recommendations on the correct use, installation, and maintenance of the appliance.

When operating this infrared heater observe necessary safety precautions, as improper use may result in injury or damage to property.

Ensure to keep this manual along with your sales receipt, and if possible, cardboard package and packing material in case a return of the unit is necessary.

  • Unpack the infrared heater making sure that all the items are present, there are no components left in the box and the heater head is free from any packing material.
  • Using the detailed diagrams follow the steps to assemble your infrared heater.
  • Do NOT connect the infrared heater to the power supply until the assembly is complete.
  • Do NOT connect the infrared heater to the power supply if any of the components are damaged in any way.

Safety Instructions

Read these instructions before using them.

WARNING

Potential fire risk if the heater is covered by any flammable materials.

  • CAUTION — Some parts of the heater can become very hot and cause burns.
  • Do NOT touch the appliance during operation to avoid the risk of injury.
  • Check that the voltage indicated on the nameplate of the appliance corresponds to the local mains voltage before the appliance is hardwired.
  • The power supply to the appliance should correspond to the relevant regulations of the power supply companies and the regional construction regulations.
  • To avoid overheating do NOT cover the heater.
  • The heater must NOT be located immediately below a socket outlet.
  • The heater must be installed at least 3.5m above the floor.
  • After fixing to a wall or ceiling, adjustments to the direction of radiation must only be made with the appropriate tools.
  • It can become a fire risk if the heater is covered or positioned incorrectly.
  • It’s dangerous to install the heater close to combustible materials.
  • Do NOT use in unventilated areas.
  • Do NOT use where gas, petrol, paint or other flammable materials are stored.
  • Do NOT push any items through, obstruct or cover the grills of the heater head.
  • Do NOT move the heater when it is connected to the power supply.
  • Always wait till the heater has cooled down completely before putting it into storage.
  • The heater must be placed with a clearance of 300cm to the wall and 40cm to the ceiling.
  • Improper use of the appliance can result in electric shock or fire hazards.
  • In case of damage, the heater must only be repaired by a professional electrician.

Cleaning & Maintenance

  • Isolate the appliance from the power supply system and wait until it has sufficiently cooled off.
  • After the appliance has cooled down, the housing can be wiped clean with a damp cloth.
  • Wipe the appliance only with a clean and lint-free cloth or a soft brush.
  • Do NOT touch the bulb element with your fingers. Stains can build up from touching the bulb and may cause the bulb to malfunction.
  • Do NOT use any abrasive or hard cleaning products on any part of this heater.
  • Wait until the unit is completely dry before use.
  • When cleaning the reflector, contact a qualified electrician to see if the reflector needs to be removed.

https://www.heat-outdoors.co.uk/help-desk/useful-articles/heater-and-lamp- maintenance.html

Any maintenance or repairs should only be carried out by a qualified electrician if you’re unsure how to do so. For further information and guidance, visit our online help articles and videos.

Assembly Instructions

Installation

  • When unpacking the heater, please make sure that all the items are present, there are no components left in the box, that all the parts are free from any packing material, and are not damaged. Ensure that the items used for mounting (dowels and screws) are stable and secure enough to mount and hold the appliance in place.
  • Do NOT connect the heater to the electrical supply until all the assembly is done.
  • Do NOT connect the heater to the electrical supply if any of the components are damaged in any way. If in doubt, please contact your local supplier.

Wall Mounting For Each Bracket

  1. Mark and drill 4 holes 10mm in diameter on the wall.
  2. Insert 4 expansion bolts into the holes, align the heater onto the bolts, and lock with 4 nuts tightly

The diagram below demonstrates the minimum safe mounting distance between the appliance and the ceiling, wall, and floor.

Shadow-Industrial-903689-Shadow-Infinity-Industrial-Infrared-Heater-
fig2

Bracket Mounting

Operation

  • The heater needs to be hardwired to the circuit, only a qualified electrician should install the appliance.

Product Dimensions

Shadow-Industrial-903689-Shadow-Infinity-Industrial-Infrared-Heater-
fig4

Wiring Diagrams

Shadow-Industrial-903689-Shadow-Infinity-Industrial-Infrared-Heater-
fig5

Technical Specifications

Shadow-Industrial-903689-Shadow-Infinity-Industrial-Infrared-Heater-
fig6

Disposal

In accordance with European Directive 2001/96/EG concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE), please return any electrical equipment that you are no longer using to the collection points provided for their disposal.

This symbol indicates that the appliance cannot be treated as normal domestic waste, it must be handed to a collection point for recycling electric and electronic appliances. Information concerning where the equipment can be disposed of can be obtained from your local authority

Storage

If the heater isn’t going to be used for a long period of time, store it in a cool, dry location. To prevent dust and dirt build-up, use the original packaging to repack the heater.

Customer Service

  • Repairs must carried out by authorized specialists, thus ensuring electrical safety.
  • Please contact us or a suitably qualified electrician.
  • Improper repairs could lead to danger to the user.

Warranty does NOT cover damage or failure that results from alteration, accident, misuse, abuse, neglect, commercial use or improper maintenance. In line with our policy of continuous product development, we reserve the right to change the product and documentation specifications without notice.

Unit 9, Stort Valley Industrial Estate

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals