Kinglumi 61019 Trick Light User Manual

June 17, 2024
Kinglumi

Kinglumi-logo

Kinglumi 61019 Trick Light

Product Information

Specifications

  • Compliance: FCC Part 15
  • RF Exposure: Minimum distance of 20cm

FAQ

  • Q: What is FCC Part 15 compliance?
  • A: FCC Part 15 compliance ensures that the device meets regulatory standards set by the Federal Communications Commission to minimize interference.
  • Q: Why is maintaining a distance of 20cm important for RF exposure?
  • A: Keeping a distance of 20cm helps reduce potential health risks associated with radiofrequency exposure.

Turn power OFF

Please follow the sequence of installation step by step. Switch off the electricity before commencing installation

Kinglumi-61019-Trick-Light-fig-2

  • Product lifespan refers to lighting time when the luminous flux of 50% luminaires in a batch of the same luminaires reaches 70% of the initial luminous flux(L70B50)..
  • The estimated product lifespan is based on the indoor ambient temperature of 25°C, good air circulation and working at rated voltage.

FEATURES

Kinglumi-61019-Trick-Light-fig-3

Dimension

Size of the luminaires

Kinglumi-61019-Trick-Light-fig-4 Kinglumi-61019
-Trick-Light-fig-5 Kinglumi-61019
-Trick-Light-fig-6

Installation Instructions

Rotation angle of the light

  • Only adjust the lighting angle when the power is OFF.
  • Please be careful when adjusting the angle, and please stop rotating in the same direction When the luminaire cap is adjusted to the stop position.

Kinglumi-61019-Trick-Light-fig-7

Recommended Installation Method

Kinglumi-61019-Trick-Light-fig-8

  • We recommended installing the track on the ceiling. It is prohibited to install the track on the side wall and the ground.

2Wire 1 Circuit (H) Track System

Kinglumi-61019-Trick-Light-fig-10

2Wire 1 Circuit (J) Track System

Kinglumi-61019-Trick-Light-fig-11

4 Wire 3Circuit Track System

Kinglumi-61019-Trick-Light-fig-12 Kinglumi-61019-Trick-Light-fig-13 Kinglumi-61019-Trick-Light-fig-14

Product Model

|

Watt

|

Input

|

Operating Current

|

Inrush Current

| Duration of inrush Current|

The Leakage Current

| Maximum Number of luminaires Connected of 16Atype B MCB/16A| Maximum Number of luminaires Connected of 16A type C MCB/16A
---|---|---|---|---|---|---|---|---
61018| 15W| 120V/60Hz| 0.18A| 3A| 115us| 0.5A| 57pcs| 66pcs
61019| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
61020| 20W| 120V/60Hz| 0.24A| 3A| 120us| 0.5A| 43pcs| S0pcs
61021| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
61022| 15W| 120V/60Hz| 0.18A| 3A| 115us| 0.5A| 57pcs| 66pcs
61023| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
61036| 15W| 120V/60Hz| 0.18A| 3A| 115us| 0.5A| 57pcs| 66pcs
61037| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
61038| 20W| 120V/60Hz| 0.24A| 3A| 120us| 0.5A| 43pcs| S0pcs
61039| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
61040| 15W| 120V/60Hz| 0.18A| 3A| 115us| 0.5A| 57pcs| 66pcs
61041| 30W| 120V/60Hz| 0.35A| 4.5A| 158us| 0.5A| 30pcs| 34pcs
 |  |  |  |  |  |  |  |

The leakage current (contact current or protective conductor current) of the circuit depends greatly on the conductor, such as the length of the conductor specification. In the field, the connection of power cord toconductor specification. In the field, the connection of the power cord to the luminaire, and the arrangement of the power cord of the luminaire also have an effect  In some cases it is also referred to as the ground drain current.

  1. Please be sure to cut off the power before operation.
  2. Do not continue to use it if the luminaire is damaged.
  3. Luminaires should not be stored and used in corrosive environments or environments containing hazardous substances such as sulphide, halides, phthalates, etc.
  4. Luminaires should be installed outside the reach of human hands.

Warming: The light source and parts of these luminaires are not replaceable. When the light source and parts reach the end of their life, the whole lamp should be replaced.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Statement
The distance between the user and the products should be no less than 20cm.