SAUTER EY6RT30 BACnet Testing Laboratories Instructions
- June 17, 2024
- SAUTER
Table of Contents
SAUTER EY6RT30 BACnet Testing Laboratories
Product Specifications
-
Vendor: Fr. Sauter AG
-
Location: Im Surinam 55, 4058 Basel,
Switzerland -
BACnet Protocol Revision: Revision 24
-
Firmware Version: V1.0.1b3871
-
Device Profiles:
- BACnet Router (B-RTR)
- BACnet Broadcast Management Device (B-BBMD)
- BACnet Secure Connect Hub (B-SCHUB)
-
BIBBs Supported:
-
Data Sharing:
-
ReadProperty-B, ReadPropertyMultiple-B
-
Write Property-B, WritePropertyMultiple-B, Change Of Value
Unsubscribed-B -
DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DS-COVU-B
-
Device Management:
-
Dynamic Device Binding-A, Dynamic Device Binding-B, Dynamic Object Binding-B, DeviceCommunicationControl-B
-
time synchronization-B, UTCTime Synchronization-B
-
ReinitializeDevice-B, Backup, and Restore-B
-
Restart-B, List Manipulation-B, Router Configuration-B, BBMD Configuration-B, Foreign Device Registration-A, Secure Connect Hub-B
-
Object Type Support: Device, File, Network Port
-
Data Link Layer Options: Media – BACnet/IP (Annex J), BACnet/SC
-
Character Set Support: ISO 10646 (UTF-8)
-
Product Usage Instructions
- Ensure the device is properly connected to the network using the specified media (BACnet/IP or BACnet/SC).
- Access the device configuration settings using the provided model numbers and firmware version.
- Configure the device profiles based on your requirements (BACnet Router, Broadcast Management Device, Secure Connect Hub).
- Utilize the supported BIBBs for data sharing and device management as needed.
- For advanced configurations, refer to the object type support and data link layer options.
Frequently Asked Questions (FAQ)
Q: How do I update the firmware of the Modulo 6 BACnet Router and SC-Hub?
A: To update the firmware, please follow these steps:
- Download the latest firmware version from the vendor’s official website.
- Access the device’s configuration interface and navigate to the firmware update section.
- Select the downloaded firmware file and initiate the update process.
- Wait for the update to complete and ensure the device restarts successfully.
Q: What should I do if I encounter connectivity issues with the device?
A: If you face connectivity issues, please try the following troubleshooting steps:
- Check the network connection and ensure all cables are securely plugged in.
- Verify that the device settings match your network configuration.
- Restart the device and check if the issue persists.
- Contact customer support for further assistance if the problem continues.
- BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve, or test products for compliance with ASHRAE standards.
- Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International.
- BTL is a registered trademark of BACnet International.
BACnet Testing Laboratories Product Listing
- BACnet functionality in each Listed product has been successfully tested at a Recognized BACnet Testing Organization utilizing the industry standard BTL test suite and test policies that were current at the time it was tested.
- For Listings with multiple products, some products may have less functionality than the Listing document indicates. The PICS document provides information on the specific functionality of each product.
- Note that the manufacturer provides PICS documents on the BTL Listings site and are not independently verified by BTL.
Listing Information (BTL-31125)
Vendor | Listing Status |
---|---|
Fr. Sauter AG Im Surinam 55 4058 Basel Switzerland | **** Listed Product |
Test Requirements | BACnet Protocol Revision |
Requirements as of June 2023 | Revision 24 |
Product Name | Model Numbers |
--- | --- |
modulo 6 BACnet Router and SC-Hub | EY6RT30F001 |
Device Profiles
Profile | Model Numbers |
---|
BACnet Router (B-RTR) BACnet Broadcast Management Device (B-BBMD) BACnet Secure Connect Hub (B-SCHUB)| **** All models
BIBBs Supported
**** Data Sharing | ReadProperty-B | DS-RP-B |
---|---|---|
ReadPropertyMultiple-B | DS-RPM-B | |
WriteProperty-B | DS-WP-B | |
WritePropertyMultiple-B | DS-WPM-B | |
Change Of Value Unsubscribed-B | DS-COVU-B | |
**** Device Management | Dynamic Device Binding-A | DM-DDB-A |
--- | --- | --- |
Dynamic Device Binding-B | DM-DDB-B | |
Dynamic Object Binding-B | DM-DOB-B | |
DeviceCommunicationControl-B | DM-DCC-B | |
time synchronization-B | DM-TS-B | |
UTCTimeSynchronization-B | DM-UTC-B | |
ReinitializeDevice-B | DM-RD-B | |
Backup and Restore-B | DM-BR-B | |
Restart-B | DM-R-B | |
List Manipulation-B | DM-LM-B | |
Router Configuration-B | NM-RC-B | |
BBMD Configuration-B | NM-BBMDC-B | |
Foreign Device Registration-A | NM-FDR-A | |
Secure Connect Hub-B | NM-SCH-B |
Object Type Support
Device | File | Network Port |
---|
Data Link Layer Options
Media | Options |
---|---|
**** BACnet/IP (Annex J) | BBMD Register as Foreign Device BACnet/IP, ‘DIX’ |
Ethernet
BACnet/SC| Hub
Character Set Support
ISO 10646 (UTF-8)