SAUTER SP 200K Internal Sensor Digital Light Meter Instruction Manual
- June 13, 2024
- SAUTER
Table of Contents
- General information
- Functions
- Technical description
- Function keys and part names
- influencing variables of the spectral sensitivity
- Steps for commissioning
- Check and replace batteries
- Maintenance
- Examples of recommended illuminance levels
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SAUTER SP 200K Internal Sensor Digital Light Meter Instruction Manual
General information
This digital illuminance meter is a precision instrument for measuring the illuminancein the work area. The sensor has a full cosine correction for oblique light incidence.The instrument is compact, robust and easy to use due to its design. The light sensitive component used in this light meter is a very stable silicon diode with a long lifetime
Functions
- FC (foot candle)
- High accuracy and fast response
- Peak-Hold function for the acquisition of peak values
- Unit and number display for easy reading
- Automatic zero setting
- Non-standard light sources are automatically corrected
- Short rise and fall times
- also suitable for LED lighting
Technical description
Display: 3 ½
digit LCDMeasuring range: 200; .000; 20.000; 200.000 Lux (20,000 lux
reading value x 10, 200,000 lux reading value x 100)20; 200; 2,000; 20,000 FC
(20,000 FC Reading value x 10)
1 FC= 10.76 Lux
Exceeded display range : Display of the highest Digit “1” appears on the
display
ccuracy: ± 4% rdg ± 10 digit up to 20,000 lux / 2,000 FC ± 5% rdg ± 10
digit up to 200,000 lux / 20,000 FCCalibrated with a standard incandescent
lamp at a colour temperature of2856K
Repeat precision: ± 2%
Temperature Characteristic value: ± 1%/°C
Measuring rate: 2 times/sec
Photosensor: Silicon photo diode with filter
Working temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 0 to 70 %RH
Storage temperature: -10°C to 50°C (14°F to 122°F)
Storage humidity: 0 to 80% RH
Power source: 1 x 9V block battery, 6F22
Operating time: 200h
Dimensions: 185mmx68mmx38mm
Weight: 130 g
Accessories: Carrying case, operating instructions, battery
Function keys and part names
- LCD Display: 3 ½ Digits with maximum reading value until 1999.
- ON/OFF: With this button the luxmeter is switched on/off.
- Hold key: With this key the current measured value can be fixed. The meter will not display new readings until the HOLD key is pressed again.
- Range: This key is used to switch between the measuring ranges 200Lux/20FC; 2.000Lux/200FC; 20.000Lux/2.000FC; 200.000Lux/ 20.000FC
- Lux/FC Unit Button: Press this button to switch between the Lux or Foodcandle (FC) unit.
- photo sensor
- Cover for sensor: Used to protect the photodiode when the light meter is not in use.
influencing variables of the spectral sensitivity
As for the photo sensor: the photodiode used with filters almost reaches the
C.I.E.(International Commission on Illumination) standard of spectral
sensitivity test characteristics. The photometric curve V ( ) is shown in the
following table:
Steps for commissioning
- Power button: The power button is used to turn the light meter on and off.
- Selection of the Lux/FC scale: Press this button to select the desired light measurement unit.
- The photo sensor cover must first be removed and the photo sensor is then held against the light source in a horizontal position.
- The nominal value of the illuminance can now be read from the LCD display.
- Measuring range exceeded: If the device only shows a “1” on the display, the input signal was too strong and a higher range must be selected.
- Data HOLD Mode: The HOLD button is pressed to enter the HOLD mode. Theluxmeter stops all further measurements. When this key is pressed again, this command is cancelled and the instrument returns to normal operation.
- After all measurements have been completed, the protective cap of the photo sensor must be replaced.
- Switch off the device.
Check and replace batteries
- As soon as a sufficient power supply is not ensured, the symbol appears on the LCD display and a battery change with a 9V block battery is necessary.
- For this purpose the device must be switched off. The battery compartment cover on the back of the instrument is opened by simultaneously pressing and sliding it in the direction of the arrow.
- The battery is removed from the housing and replaced by a new 9V block battery.
- Then the battery cover is reattached.
Maintenance
- The white protective cap on the photo sensor should be wiped with a damp cloth from time to time.
- The Light Meter should not be stored at excessive temperature or humidity.
- The respective period of time for a calibration of the photo sensor varies with the working operations. In general, the light sensitivity decreases directlyproportional to the product of the light intensity of the working time.
To maintain the general accuracy of the instrument, periodic calibration is recommended.
Examples of recommended illuminance levels
Office
Conference/reception room: 200-750
Office work: 700-1500
machine writing, technical drawing: 1000-2000
School
Lecture hall, gymnasium: 100-300
Classroom: 200-750
Laboratory, library, drawing room: 5 00-1500
Factory
Packing work, goods receipt : 150-300
Work on the assembly line: 300-750
Visual inspection work: 750-1500
Assembly work of electronic parts : 1500-3000
Hotel
Social room, cloakroom: 100-200
Reception, cashier: 220-1000
retail shop
Entrance stairs range: 150-200
Shop windows, packing tables : 750-1500
Front area of the shop window: 1500-3000
Note:
When the protective cap is on the photoelectric sensor, the display shows
“0.00”continuously. If this is the case, please do not influence the
potentiometer on the back of the housing.
Note:
To view the CE declaration, please click on the following link: https://www
.kern-sohn.com/shop/de/DOWNLOADS/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>