SAUTER TI-HED Shore Test Stand Instruction Manual

June 17, 2024
SAUTER

SAUTER TI-HED Shore Test Stand

SAUTER-TI-HED-Shore-Test-Stand-product

Product Information

Specifications

  • Model: SAUTER TI-HED TI-HEA
  • Hardness Scales: Shore D, Shore A
  • Test Force Hardness Measurement: 50N, 10N
  • Overall Dimensions: Net weight approx. 10kg, 6kg

Frequently Asked Questions

  • Q: Can I use the test stand for materials other than plastics?
    • A: The test stand is specifically designed for hardness testing of plastics using the Shore A and D scales. It is recommended to consult the manufacturer for testing other materials.
  • Q: How do I connect the test stand to a PC for data transfer?
    • A: The test stand features a Data Interface RS-232 for bidirectional connection to a printer or PC. You can use suitable software provided by the manufacturer for data transfer.
  • Q: Is it possible to save measurements within the test stand?
    • A: Yes, the test stand includes an internal memory where measurements can be saved for future reference or analysis.

Product Usage Instructions

Setting up the Test Stand:

  • Place the SAUTER TI-HE test stand on a stable surface in a well-lit area.
  • Ensure all components are securely attached.

Conducting Hardness Testing:

  • Attach the appropriate hardness testing tool for either Shore A or Shore D scale.
  • Apply the test force as specified for accurate measurements.

Using the Features

  • Adjusting Program (CAL): Use an external adjusting weight for quick accuracy setting.
  • Calibration Block: Standard for adjusting or correcting the measuring device.
  • Peak Hold Function: Capture peak values during the measuring process.
  • Scan Mode: Continuously capture and display measurements.
  • Push and Pull: Measure tension and compression forces.

Features

SAUTER-TI-HED-Shore-Test-Stand-fig-1

  • High-quality test stand for Shore hardness testing of plastics in industry and the laboratory
  • 1. One test stand for two hardness scales: The test stand TI-HEA only requires the additional weight TI-HE to be screwed onto so it is also suitable for Shore D hardness tests, see Accessories
  • 2. Level adjustment: For the precise levelling of the steel base plate, e.g. for the correction of inhomogeneous test objects
  • Robust design enables accurate measuring movements
  • 3. Simple handling means that you can achieve repeatable measuring results
  • Hardness measuring device is not included with delivery

Technical data

  • Maximum stroke length: 20 mm
  • Maximum test object height: 50 mm
  • Base plate ∅ 115 mm

Accessories

  • 1. Option Shore D pour TI-HE: Additional weight for TI-HEA test stand, SAUTER TI-HE

More Information

STANDARD

Information

SAUTER-TI-HED-Shore-Test-Stand-fig-43

SAUTER Pictograms

  • Adjusting program (CAL)

    • For quick setting of the instrument’s accuracy.
    • External adjusting weight required
  • Calibration block

    • Standard for adjusting or correcting the measuring device
  • Peak hold function

    • Capturing a peak value within a measuring process
  • Scan mode

    • Continuous capture and display of measurements
  • Push and Pull

    • The measuring device can capture tension and compression forces
  • Length measurement

    • Captures the geometric dimensions of a test object or the movement during a test process
  • Focus function

    • Increases the measuring accuracy of a device within a defined measuring range
  • Internal memory

    • To save measurements in the device memory
  • Data interface RS-232

    • Bidirectional, for connection of printer and PC
  • Profibus

    • For transmitting data, e.g. between scales, measuring cells, controllers and peripheral devices over long distances. Suitable for safe, fast, fault-tolerant data transmission. Less susceptible to magnetic interference
  • Profinet

    • Enables efficient data exchange between decentralised peripheral devices (balances, measuring cells, measuring instruments etc.) and a control unit (controller).
    • Especially advantageous when exchanging complex measured values, device, diagnostic and process information. Savings potential through shorter commissioning times and device integration possible
  • Data interface USB

    • To connect the measuring instrument to a printer, PC or other peripheral devices
  • Bluetooth* data interface

    • To transfer data from the balance/measuring instrument to a printer, PC or other peripherals
  • WIFI data interface

    • To transfer data from the balance/measuring instrument to a printer, PC or other peripherals
  • Data interface infrared

    • To transfer data from the measuring instrument to a printer, PC or other peripheral devices
  • Control outputs (optocoupler, digital I/O)

    • To connect relays, signal lamps, valves, etc.
  • Analogue interface

    • To connect a suitable peripheral device for analogue processing of the measurements
  • Analogue output

    • For output of an electrical signal depending on the load (e.g. voltage 0 V – 10 V or current 4 mA – 20 mA)
  • Statistics

    • Using the saved values, the device calculates statistical data, such as average value, standard deviation etc.
  • PC Software

    • To transfer the measurement data from the device to a PC
  • Printer

    • A printer can be connected to the device to print out the measurement data
  • Network interface

    • For connecting the scale/ measuring instrument to an Ethernet network
  • KERN Communication Protocol (KCP)

    • It is a standardized interface command set for KERN balances and other instruments, which allows retrieving and controlling all relevant parameters and functions of the device.
    • KERN devices featuring KCP are thus easily integrated with computers, industrial controllers and other digital systems
  • GLP/ISO record keeping

    • GLP/ISO record keeping of measurement data with date, time and serial number. Only with SAUTER printers
  • Measuring units

    • Weighing units can be switched to e.g. non-metric.
    • Please refer to website for more details
  • Measuring with tolerance range (limit-setting function)

    • Upper and lower limiting can be programmed individually. The process is supported by an audible or visual signal, see the relevant model
  • Protection against dust and water splashes IPxx

    • The type of protection is shown in the pictogram cf.
    • DIN EN 60529:2000-09, IEC 60529:1989
    • +A1:1999+A2:2013
  • ZERO

    • Resets the display to “0”
  • Battery operation

    • Ready for battery operation. The battery type is specified for each device
  • Rechargeable battery pack

    • Rechargeable set
  • Plug-in power supply

    • 230V/50Hz in standard version for EU. On request GB, AUS or US version available
  • Integrated power supply unit

    • Integrated, 230V/50Hz in EU. More standards e.g. GB, AUS or US on request
  • Motorised drive

    • The mechanical movement is carried out by a electric motor
  • Motorised drive

    • The mechanical movement is carried out by a synchronous motor (stepper)
  • Fast-Move

    • The total length of travel can be covered by a single lever movement
  • Conformity assessment

    • Models with type approval for construction of verifiable systems
  • DAkkS calibration possible

    • The time required for DAkkS calibration is shown in days in the pictogram
  • Factory calibration (ISO)

    • The time required for factory calibration is specified in the pictogram
  • Package shipment

    • The time required for internal shipping preparations is shown in days in the pictogram
  • Pallet shipment

    • The time required for internal shipping preparations is shown in days in the pictogram
  • The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by KERN & SOHN GmbH is under license.
    Other trademarks and trade names are those of their respective owners.

Contact

SAUTER GmbH

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals