PENTAIR EF-1500 Full Flow Drinking Water Filtration System Installation Guide
- June 17, 2024
- Pentair
Table of Contents
PENTAIR EF-1500 Full Flow Drinking Water Filtration System
Thank you
Thank you for purchasing an Everpure by Pentair commercial grade water filtration system for your home. With your Everpure by Pentair system, you get premium quality water direct from your tap that’s great-tasting, healthful and convenient for you and your family.
PRODUCT SPECIFICATIONS
- For Cold Water Use Only
- Temperature Range: 35-100°F
- Min.-Max. Working Pressure: 10-125 psi
EF-6000| 1.67 gpm| 6,000 gallons, or at least once a year.
---|---|---
EF-3000| 2.2 gpm| 3,000 gallons, or at least once a year.
EF-1500| 2.2 gpm| 1,500 gallons, or at least once a year.
See Performance Data Sheet for further Performance and specification information
TOOLS REQUIRED FOR INSTALLATION
- Phillips Screwdriver
- Adjustable Wrench
- Tape Measure
- Pencil
BASIC INSTALLATION INSTRUCTIONS
- Open Carton & Inspect Parts
Installation Parts
Key | Description | Part No. |
---|---|---|
1 | QL3 Filter Head | EV927082 |
2a | EF-1500 Filter Cartridge | EV985850 |
2b | EF-3000 Filter Cartridge | EV985750 |
2c | EF-6000 Filter Cartridge | EV985550 |
3 | 2 Locking Washers | EV306204 |
4 | 2 Screws | EV306196 |
5 | 3/8-inch MPT x 3/8-inch FTP Elbow | EV310852 |
6 | (2) 3/8-inch x 1/2-inch Unions | EV312251 |
7 | (2) 3/8-inch x 3/8-inch Unions | EV312250 |
8 | Plumber Tape | EV312119 |
9 | Everpure Filter Timer | EV314160 |
– For purchase of replaceable components please contact your local distributor
- Verify Under-Sink Mounting Location Measure 22”, 20”or 15” (depending on cartridge -see dimensions below) from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.
DIMENSION| Width| Height| Depth
---|---|---|---
EF-1500| 5 inches| 15 inches| 5 inches
EF-3000| 5 inches| 20 inches| 5 inches
EF-6000| 5 inches| 22 inches| 5 inches
NOTE: The head and cartridge must be mounted in the vertical position, with
the cartridge hanging down.
SPECIAL NOTICES
* Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
* Check for compliance with state and local laws and regulations.
* Spent adsorption media will not be regenerated and used.
* If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter.
CALIFORNIA PROPOSITION 65 WARNING
This product contains chemicals known to the State of California to cause
cancer or birth defects or other reproductive harm.
The EF-1500, EF-3000, & EF-6000 are Tested and Certified by NSF International
against CSA B483.1 and NSF/ANSI 42, 53 and 401 for the claims specified on the
Performance Data Sheet.
-
Mount Filter Head Under Sink
NOTE: Two sets of unions are included to connect to the 3/8- inch head connections. If your existing braided tubing has 1/2-inch connections, use the 1/2-inch x 3/8-inch unions instead of the 3/8-inch x 3/8-inch unions. You will have 2 extra fittings with either installation. The following instructions are for a typical installation using 1/2-inch supply lines.
A. Apply plumber tape to the small threads of one Union Fitting and screw into the open end of the Elbow. Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.
B. Apply plumber tape to the threads of the Elbow Fitting and screw into the inlet (left) side of the Filter Head. Hand tighten only.
C. Apply plumber tape to the small threads of the second Union Fitting, and screw into the right side of the filter head in the same manner.
D. Securely mount the filter head on the cabinet wall using the enclosed mounting screws and washers.
-
Connect Inlet Water Supply
E. Locate and close the cold water shut-off valve under your sink. Open cold water line of faucet to release water pressure.
F. Unscrew and disconnect the braided tubing on top of cold water shut- off valve.
G. Attach one end of the new braided tubing to the top of the cold water shut-off valve.
H. Attach the other end of the new Braided Tubing to the inlet side of the filter head (Union & Elbow Fittings).
-
Attach Filtered Water To Cold Line of Faucet
I. Attach open end of existing Braided Tubing to Union Fitting on outlet side (right) of new Filter Head. Hand tighten to avoid damage to fittings.
-
Install And Flush Filter Cartridge
J. Lift handle of the build-in shut off (QC Valve) on the Head.
K. Hold Head firmly with one hand.
L. Align cartridge lug with label on filter Head.
M. Insert filter Cartridge—Push upwards.
N. Turn it to the right—About 1⁄4 turn—Until rotation stops.
O. Open cold water valve and check for leaks up to Inlet\ Elbow Fitting.
P. Open Water Faucet (not pictured).
Q. Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridges for at least 3 minutes to remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more than one week, please contact Pentair Technical Support for assistance: 800-279-9404
R. Activate Filter Timer by pinching bubble until you feel a change in resistance as the Filter timer “pops.” Within a few seconds, a thin RED line will appear in the white window showing the Timestrip(R) has been activated. Peel away backing and adhere to desired location. When the white window is completely filled with RED, it is time to replace your product.
EF-1500 Cartridge – Part No. EV985850
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
FEATURES
- Finely polishes treated water to premium quality for drinking and cooking.
- Reduces chlorine taste and odor.
- NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
- Reduces common earthy, moldy, fishy tastes and odors.
**HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI***
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance| Influent Challenge Concentration| Max. Permissible Product Water
Concentration| Reduction Requirements| Minimum Reduction| Average Reduction
---|---|---|---|---|---
Standard 42—Aesthetic Effects
Chlorine| 2.0 mg/L ± 10%| | ≥ 50%| | 97.2%
Particulate, Class I particles 0.5 to| at least 10,000 particles/mL| | ≥ 85%|
| 99.9%
Standard 53—Health Effects
Cyst| Minimum 50,000/L| | 99.95%| 99.99%| 99.99%
Lead 8.5| 0.15 mg/L ± 10%| 0.010 mg/L| | 98.1%| 98.8%
Lead 6.5| 0.15 mg/L ± 10%| 0.010 mg/L| | 99.3%| 99.3%
*Tested using flow rate = 2.2 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
- Capacity: 1500 gallons (5,600 liters)
- Pressure requirement: 10-125 psi (0.7 – 8.6 bar), non-shock
- Temperature: 35-100°F (2°-38°C)
- Flow Rate: 2.2 gpm (8.3 lpm)
GENERAL INSTALLATION/OPERATION/MAINTENANCE REQUIREMENTS
- Space required: 5”W x 15”H x 5”D (13 x 38 x 13 cm) including 2-1/2 inches of clear space under unit for cartridge change.
- Install vertically with cartridge hanging down.
- Use minimum length of tubing possible.
- Flush new cartridge at full flow for three minutes to purge air.
- Replace cartridges when capacity is reached, or when flow becomes too slow, but at least annually.
SPECIAL NOTICES
- Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
- This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
- Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction that may contain filterable cysts.
- The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
- Check for compliance with state and local laws and regulations.
- Tests run under standard laboratory conditions. Actual performance may vary.
- Spent adsorption media will not be regenerated and used.
- If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter.
EPA Est. 002623-IL-002
The EF-1500 is Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance S Data Sheet.
EF-3000 Cartridge – Part No. EV985750 (1-pack)
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
FEATURES
- Finely polishes treated water to premium quality for drinking and cooking.
- Reduces chlorine taste and odor.
- NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
- Reduces common earthy, moldy, fishy tastes and odors.
- Reduces lead.
**HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI***
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Substance| Influent Challenge Concentration| Max. Permissible Product Water
Concentration| Reduction Requirements| Minimum Reduction| Average Reduction
---|---|---|---|---|---
Standard 42—Aesthetic Effects
Chlorine| 2.0 mg/L ± 10%| | ≥ 50%| | 99.0%
Particulate, Class I particles 0.5 to| at least 10,000 particles/mL| | ≥ 85%|
| 98.3%
Standard 53—Health Effects
Cyst| Minimum 50,000/L| | 99.95%| 99.99%| 99.99%
Lead 6.5| 0.15 mg/L ± 10%| 0.010 mg/L| | 93.2%| 98.5
Lead 8.5| 0.15 mg/L ± 10%| 0.010 mg/L| | 99.9%| 99.9%
*Tested using flow rate = 2.2 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C
OPERATING SPECIFICATIONS
- Capacity: 3000 gallons (11,200 liters)
- Pressure requirement: 10-125 psi (0.7 – 8.6 bar), non-shock
- Temperature: 35-100°F (2°-38°C)
- Flow Rate: 2.2 gpm (8.3 lpm)
GENERAL INSTALLATION/OPERATION/MAINTENANCE REQUIREMENTS
- Space required: 5”W x 20”H x 5”D (13 x 51 x 13 cm) including 2-1/2 inches of clear space under unit for cartridge change.
- Install vertically with cartridge hanging down.
- Use minimum length of tubing possible.
- Flush new cartridge at full flow for three minutes to purge air.
- Replace cartridges when capacity is reached, or when flow becomes too slow, but at least annually.
SPECIAL NOTICES
- Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
- This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
- Do not use with water that is microbiologically unsafe, or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on waters that may contain filterable cysts.
- The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
- Check for compliance with state and local laws and regulations.
- Tests run under standard laboratory conditions. Actual performance may vary.
- Spent adsorption media will not be regenerated and used.
- If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter.
EPA Est. 002623-IL-002
The EF-3000 is Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
Customer Support
For Everpure§Product Warranties visit: www.everpure.com
13845 BISHOPS DR., SUITE 200, BROOKFIELD, WI 53005
EVERPURE.COM | CUSTOMER CARE: 800.279.9404 | tech-
support@pentair.com
©2023 Pentair Residential Filtration, LLC. All rights reserved.
§ For a detailed list of where Pentair trademarks are registered, please visit
waterpurification.pentair.com/brands.
Pentair trademarks and logos are owned by Pentair plc or its affiliates.
Third party registered and unregistered trademarks and logos are the property
of their respective owners. 4004794 REV C DE23
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>