TASKLighting LP42HR21NDBBK30 Lighted Power Strip Instruction Manual

June 17, 2024
TASKLighting

TASKLighting LP42HR21NDBBK30 Lighted Power Strip

TASKLighting LP42HR21NDBBK30 Lighted Power Strip 

General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

General Guidelines

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

Wiring for Combined Light and Receptacle Circuit – Non Dimmable

Wiring for Combined Light and Receptacle Circuit - Non Dimmable

Step 1
Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN wires to PEM studs inside of back frame.

Step 2
When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.

Step 3
To terminate last LPS, use wire nuts on ends of wires

Step 4
Snap cover in place and turn power on.

Snap cover in place and turn power on.

Wiring for Separate Light and Receptacle Circuits

Step 1
Secure LPS to wall by screwing into wall studs or use anchors provided. If running two circuits, one for receptacles, one for lighting, connect fixture wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

Step 2
When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.

Step 3
To terminate last LPS, use wire nuts on ends of wires.

Step 4
Snap cover in place and turn power on.

Wiring Diagram for Combined Light & Receptacle Circuit – Non Dimmable

Wiring Diagram for Combined Light & Receptacle Circuit - Non
Dimmable

Wiring Diagram for Separate Light & Receptacle Circuits

Wiring Diagram for Combined Light & Receptacle Circuit - Non
Dimmable

General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

General Guidelines
General Guidelines

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.

General Guidelines

Remote Power Supply- 120V Entry

Step 1

Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK to BLACK, WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.

Step 2
When connecting two LPS, run Romex from fixture to fixture. Ground each section to the next.

Step 3
To terminate last LPS, use wire nuts on ends of wires.

Step 4
Using appropriate knockout hole, pull low voltage wire from remote power supply into the low voltage space, connect BLACK wire (negative) to BLACK wire from lights and RED wire (positive) to RED wire.

Step 5
Snap cover in place and turn power on.

Customer Service

Customer Service: 800.445.6404 • Design Services/Technical Support: 866.848.9094 • TaskLighting.com

Customer Service: 800-445-6404 Design Services & Tech Support: 866-848-9094

Symbols

www.TaskLighting.com
DesignAndSupport@TaskLighting.com

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals