Sanitas SMA 36 Electric Nail File Manicure and Pedicure Set Instructions
- June 17, 2024
- Sanitas
Table of Contents
SMA 36
Manicure/Pedicure set
Instruction for Use
SMA 36 Electric Nail File Manicure and Pedicure Set
Read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
Warning
- This device may be used by children over the age of 8 and by people with reduced physical, sensory or mental skills or a lack of experience or knowledge, provided that they are supervised or have been instructed on how to use the device safely, and are fully aware of the consequent risks of use.
- Children must not play with the device.
- Cleaning and user maintenance must not be performed by children unless supervised.
- Do not use the device if it shows signs of damage or does not function properly. In these cases, contact Customer Services.
- Repairs must only be carried out by Customer Services or authorised suppliers.
- If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed, the device must be disposed of.
- The unit is only intended for domestic/private use, not for commercial use.
- Under no circumstances should you open or repair the device yourself, as faultless functionality can no longer be guaranteed thereafter. Failure to adhere to this instruction will void the warranty.
Items included in the package
– Manicure and pedicure device
– 7 high-quality attachments made from sapphire and felt
– Adapter
– Storage pouch
– These instructions for use
Important notes
**** Please ensure that no hair can get caught in the rotating attachments
when using the device. Use a hair tie for your safety.
When in use, there may be an intense heat build-up on the skin or nail.
– Check results regularly during treatment. This is particularly advisable in
the case of diabetics, as they are less sensitive to pain and are liable to
become injured more easily.
Attachments 1, 2, 3, 4 and 5 that are provided are basically suitable for
diabetics as they are only used for treatment of areas rather than specific
points. Attachments 6 and 7 are, however, less suitable for diabetics. Always
use with extreme care.
If in doubt, ask your doctor.
– This instrument must be used only for the purpose for which it has been
developed, and in the manner described in the instructions for use. Any
improper use can be dangerous.
– In case of prolonged intensive use (e.g. milling of dead skin from your
feet) the device might get very hot. In order to prevent skin burns in these
situations, there should be longer breaks between each application. For your
own safety, constantly monitor heat build up in the device. This particularly
applies to people who are insensitive to heat.
– The device is only for private use and is not intended for medical or
commercial purposes.
– For reasons of hygiene, the device should only be used on one person.
– The manager is not responsible for damage or injury caused by improper or
incorrect use.
– Keep children away from the packaging materials. Risk of suffocation.
– The appliance must be checked frequently for signs of wear or damage. If
such signs are present, or if the appliance has been used improperly, it must
be taken to either the manufacturer or the dealer before further use.
– Switch off the instrument immediately in the event of defects or
malfunctions.
– Repairs may be carried out only by the customer service or authorized
dealers.
– On no account try to repair the instrument yourself!
– Use the instrument only with the accessories provided.
– Never operate the appliance without supervision, particularly when children
are in the vicinity.
– Do not use on small animals/animals.
– Prevent all contact with water (except when cleaning with a slightly
moistened cloth!). Water must never enter the inside of the appliance. Never
immerse the appliance in water. On no account use the appliance in the bath,
in a shower, in a swimming pool or over a water-filled wash basin. In the
unlikely event that water gets into the case, disconnect the appliance
immediately from the mains and contact your specialist electrical supplier or
customer service.
– Keep the instrument away from sources of heat.
– Do not use the instrument under blankets, pillows etc.
– The instrument must not be operated continuously for longer than 20 minutes.
After this time, wait an interval of at least 15 minutes to prevent the motor
from overheating.
– Ensure your hands are dry before handling either the instrument or the plug-
in power unit.
– Do not pull on the power cord or instrument to unplug the plug-in power unit
from the socket outlet.
– The plug-in power unit must be operated only from a power supply as
specified on it.
– The appliance should only be operated with the power unit provided.
– After use, before cleaning and changing any accessory parts, the power unit
should always be disconnected.
Preparation
This manicure and pedicure instrument is equipped with high-quality
attachments.
The basic version includes 7 attachments with long-life sapphire coating or
polishing felt.
Together with the 2-level speed control and clockwise/anticlockwise operation,
this ensures a professional pedicure and manicure that would otherwise only be
possible at a podiatrist.
Application
General
– This instrument is intended only for the treatment of hands (manicure) and
feet (pedicure).
– Make sure that the device is switched off beforehand.
– Select an attachment and push it onto the instrument spindle using a slight
pressure. To remove: pull the attachment and instrument apart in the axial
direction (straight).
– Switch the device on by moving the slide switch down (anticlockwise, LED
red) or up (clockwise, LED green).
– You can choose between two speed settings („Hi“ and „Lo“). To set the
desired speed setting, push the switch up („Hi“) or down („Lo“).
– All file and cutting attachments are coated with a sapphire grain.
This guarantees extremely long life and almost guarantees freedom from wear.
– Do not exert heavy pressure and always guide the attachments carefully over
the surface to be treated.
– Move the instrument under light pressure in circular movements slowly over
the parts to be treated.
– Note that the cutting attachments will have a reduced effect if the skin is
softened or moist. For this reason, do not carry out any pretreatment in a
bath.
– Do not remove all the callus skin in order to retain the natural protection
of the skin.
– Always ensure that the spindle can rotate freely. It must never be
permanently jammed, otherwise the instrument will become too hot and suffer
damage.
– After every use, apply moisturizing cream to the parts treated.
Important:
** Check the results during treatment. This is particularly important for
diabetics, since their hands and feet are less sensitive.
Attachments**
As these are attachments for use by professionals, we would ask you to handle
them with care as they can cause injury when used incorrectly. Particular
caution is advised at higher speeds.
The following attachments are provided with your appliance:
-
Sapphire disk, fine
Filing and treatment of the nails, fine grained sapphire disk. The specific aspect of this sapphire disk is that only the inner disk rotates, while the outer support is stationary. This enables precise filing of the nails without the risk of burning the skin with the fast rotating disk. -
Sapphire disk, coarse
Filing and treatment of the nails, coarse grain sapphire disk. This attachment allows you to shorten even thick nails by filing. Since it quickly removes large areas of the nail, you should proceed with caution in this case also. -
Sapphire cone
Removal of dry skin or calluses from the soles of the feet and from the heels and for manicuring the nails. -
Felt cone
Smoothing and polishing the edge of the nail after filing as well as for cleaning the nail surface. Always polish in circular movements and do not allow the felt cone to rest in one place, otherwise friction could cause heat to develop. -
Sapphire callus rasp
For rapid removal of stubborn calluses and hard skin on the soles of feet and heels This attachment can be used on large areas. -
Cylindrical milling cutter
Grinding of lignified foot nail surfaces as well as smoothing of these. For this purpose, apply the milling cutter horizontally to the nail surface and remove the unwanted layer of nail using slow circular movements. -
Flame milling cutter
For removing ingrowing nails. Carefully guide the flame cutter up to the part to be treated and remove parts of the nail as necessary.
When filing, always work from the outside of the nail towards the tip!
Always check results regularly during treatment. As soon as the application
becomes unpleasant, stop the treatment.
Cleaning/care
Before cleaning the power unit, always unplug it from the socket outlet!
– Clean the instrument with a slightly moistened cloth. You can also moisten
the cloth with mild soap suds to remove more stubborn dirt.
– If necessary, for reasons of hygiene, the attachments can be cleaned with a
cloth or brush moistened with alcohol. Dry them carefully afterwards.
– Do not drop the instrument.
– Make sure that no water enters the instrument. But if this should happen, do
not use the instrument again until it is completely dry.
– Do not use chemical detergent or scouring agents for cleaning.
– Never immerse the instrument or plug-in power unit in water or other
liquids.
Disposal
**** For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.
Technical specifications
Supply
Input:
Output:| 100-240 V~; 50/60 Hz 0.5 A
30.0 V 0.25 A; 7.5 W
---|---
Average active efficiency:| ≥ 80.3 %
No-load power consumption:| ≤ 0.09 W
Speed:| 3,800 – 4,600 +/- 15%
Device dimensions:| 15.2 x 3.7 x 3.7 cm
Weight:| Mains part: approx. 93 g
Device: approx. 100 g
Replacement items
For replacement parts and additional items contact the corresponding service
address in your country (according to the service address list).
Replacement parts and additional items are also available from retailers.
Subject to technical changes
Item | Item number |
---|
1 x Sapphire disk, fine
1 x Sapphire disk, coarse
1 x Sapphire cone
1 x Felt cone
1 x Sapphire callus rasp
1 x Cylindrical milling cutter
1 x Flame milling cutter| 572.09
Warranty/service
Hans Dinslage GmbH, Riedlinger Straße 28, 89524 Uttenweiler, Germany
(hereinafter referred to as “HaDi”) provides a warranty for this product,
subject to the requirements below and to the extent described as follows.
The warranty conditions below shall not affect the seller’s statutory warranty
obligations which ensue from the sales agreement with the buyer. The warranty
shall apply without prejudice to any mandatory statutory provisions on
liability.
HaDi guarantees the perfect functionality and completeness of this product.The
worldwide warranty period is 2 years, commencing from the purchase of the new,
unused product from the seller.
The warranty only applies to products purchased by the buyer as a consumer and
used exclusively for personal purposes in the context of domestic use.German
law shall apply.
During the warranty period, should this product prove to be incomplete or
defective in functionality in accordance with the following provisions, HaDi
shall carry out a repair or a replacement delivery free of charge, in accor-
dance with these warranty conditions.
If the buyer wishes to make a warranty claim, they should approach their local
retailer in the first instance: see the attached “International Service” list
of service addresses.
The buyer will then receive further information about the processing of the
warranty claim, e.g. where they can send the product and what documentation is
required.
A warranty claim shall only be considered if the buyer can provide HaDi, or an
authorised HaDi partner, with
– a copy of the invoice/purchase receipt, and
– the original product.
The following are explicitly excluded from this warranty:
– deterioration due to normal use or consumption of the product;
– accessories supplied with this product which are worn out or used up through
proper use (e.g. batteries, rechargeable batteries, cuffs, seals, electrodes,
light sources, attachments and nebuliser accessories);
– products that are used, cleaned, stored or maintained improperly and/or
contrary to the provisions of the instructions for use, as well as products
that have been opened, repaired or modified by the buyer or by a service
centre not authorised by HaDi;
– damage that arises during transport between manufacturer and customer, or
between service centre and customer;
– products purchased as seconds or as used goods;
– consequential damage arising from a fault in this product (however, in this
case, claims may exist arising from product liability or other compulsory
statutory liability provisions).
Repairs or an exchange in full do not extend the warranty period under any
circumstances.
Hans Dinslage GmbH, Riedlinger
Straße 28, 88524 Uttenweiler, Germany
Documents / Resources
|
Sanitas SMA 36 Electric Nail File Manicure and Pedicure
Set
[pdf] Instructions
SMA 36 Electric Nail File Manicure and Pedicure Set, SMA 36, Electric Nail
File Manicure and Pedicure Set, File Manicure and Pedicure Set, Manicure and
Pedicure Set, Pedicure Set
---|---