HEATROD Prefix A HE Domestic Immersion Heaters Instructions

June 17, 2024
HEATROD

HEATROD Prefix A HE Domestic Immersion Heaters

HEATROD-Prefix-A-HE-Domestic-Immersion-Heater-product

Specifications

  • Manufacturer: Heatrod Elements Ltd.
  • Model: Immersion Heater Types A,B,C,D
  • Conformance: EN60335.2.73, EEC Directive BS EN 550141:2006+A2:2011, EEC Directive 76/889, BS800:1977
  • Approval: NEMKO
  • Warranty: 12 months parts only

Product Usage Instructions

  1. Check that the heater rating label matches your mains supply voltage.
  2. Install the heater into the water tank or cylinder using theprovided O-ring or gasket. Use a shaped immersion heater spanner for installation.
  3. Ensure the heater operates below water level in a suitable tank (cistern-fed or mains regulated).
  4. Check for water leakage before proceeding to the wiring stage.
  5. Refer to the schematic wiring diagram for proper installation.
  6. Use approved thermal controls (Thermowatt type: R.T.S-3, Cotherm TSE00187).
  7. Isolate the heater from mains electricity before making any adjustments within the terminal cover.
  8. Supervise children when near the appliance.
  9. If thermostat/cut-out issues persist, replace the device using manufacturer-provided details.

FAQ

  1. Q: Where can I find technical help or assistance?
    A: For technical support, refer to the FAQ’s website at www.heatrod.com or www.heatrodshop.com. You can also contact technical support via phone at 0161 727 3713, fax at 0161 727 3733, or email at technicalsupport@heatrod.com.

  2. Q: What is the warranty policy for the product?
    A: All products come with a standard 12-month parts-only warranty. Faulty products can be returned for replacement or credit within this period. For further details, visit the manufacturer’s website.

  3. Q: Can the product be recycled?
    A: Yes, at the end of its life cycle, the product can be recycled. Contact Heatrod Elements Limited for disposal instructions.

Instructions

`For further information on the HWA Charter Membership, please refer to the HWA website hotwater.org.uk

Fitting Instructions for Immersion Heater Types :
Heaters Having Part No. Prefix A,B,C,D Heaters Conform to EN60335.2.73

  1. Check that the heater rating label shows the voltage that conforms to your mains supply.

  2. Install the heater into the water tank or cylinder using the O-ring or gasket supplied. Use a shaped immersion heater spanner- Stillsons should not be used. The heater may be installed into a tank of any size, suitable to take this heater when installed in a horizontal manner, the heater must operate below water level, such as in a cistern-fed or mains regulated tank, if applicable.

  3. It is essential that the installer checks that the water level within the tank or cylinder is such that the water will always fully cover the heating element by a depth of at least 100mm. Under NO circumstances must the heater be allowed to run dry – serious damage may result to the heater in addition to danger of personal injury and damage to property.

  4. Check the heater for possible water leakage before moving on to the wiring stage.
    See overleaf for the schematic wiring diagram.

  5. The heater is to be wired with cable having a minimum size of 1.5 sq mm., 90ºC elastomer insulated H05BN4-F sheathed cable to BS6500. The heater MUST be fully earthed and wired through a double pole switch having a contact separation of at least 3mm in accordance with the wiring rules. Ensure all terminal connections are securely made and there are no loose strands. Do not use excessive force when tightening terminals.

  6. NEMKO approval will only apply to Approved Heaters if the following thermal controls are used :

    • Thermowatt type : R.T.S-3 , Cotherm TSE00187. The heater conforms to the EEC Directive BS EN 55014- 1:2006+A2:2011 for Electromagnetic compatibility.
      Warning: Before making any adjustments within the heater terminal cover, isolate the heater from the mains electricity supply. DO NOT COVER the heater cap.

    • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with this appliance.

  7. In the event of the manually resettable cut-out within the thermostat operating range, isolate the heater from the mains supply before removing the terminal cover. Investigate and identify the cause for the operation of the cut-out, and rectify if possible before manually resetting the device by pressing the small button located on the top of the ther-mostat housing. At the same time, to prevent re-occurrence, it is advisable to turn down the temperature setting on the thermostat to around 55°C. Refer to FAQ’s website.
    It must be noted that if the cylinder is also heated by a secondary source such as solar energy, or by an oil or coal-fired boiler producing heat higher than the cut-out pre-set temperature, this can also cause the cut-out to operate. It is not recommended that the thermostat is set higher than 60°C.

  8. Important: It is not necessary for the heater to be removed to rectify any problems with the thermostat/cut-out. If the fault persists, the device can be replaced. Replacement thermostats can be obtained from the immersion heater manufacturer using the details overleaf.

  9. All heaters conform with EEC Directive 76/889 for Radio Interference and comply with BS800:1977
    Heatrod Elements Ltd . Unit 10 Top Deck . Smethurst Lane. Bolton . BL4 0AN Document Ref. MS-011

  10. Schematic Wiring Diagram, Earth Assembly Diagram and Cable Grip Fitment Details.
    HEATROD-Prefix-A-HE-Domestic-Immersion-Heater-1 HEATROD-Prefix-A-HE-Domestic-Immersion-Heater-2

Manufactured in the UK.
PLEASE RETAIN THIS LEAFLET FOR FUTURE REFERENCE
IT IS THE INSTALLERS RESPONSIBILITY TO CHECK ALL CONNECTIONS, INCLUDING FACTORY-MADE CONNECTIONS.

Warranty Information

All products carry a standard 12-month parts-only warranty. Products that are deemed faulty can be returned for replacement or credit at any time within this warranty period.

PLEASE SEE OUR WEBSITE FOR FURTHER DETAILS.
For Technical Help or Assistance—Refer to FAQ’s website
www.heatrod.com or www.heatrodshop.com

Environmental Information

Please note this product can be recycled at the end of its life cycle.
If required this product can be returned to Heatrod Elements Limited for disposal.

Heatrod Elements Ltd . Unit 10 Top Deck . Smethurst Lane. Bolton . BL4 0AN Document Ref. MS-011