CONSORT CLAUDGEN HE7230SL Recessed Fit Downflow Ceiling Heater User Manual
- June 5, 2024
- CONSORT CLAUDGEN
Table of Contents
CONSORT CLAUDGEN HE7230SL Recessed Fit Downflow Ceiling Heater
Introduction
This instruction manual describes the CLAUDGEN Recessed Warm Air Ceiling Heaters. The heater is designed for discreet positioning in a suspended 600mm ceiling within retail or commercial premises. It can fit a recess as shallow as 210mm
General Information
General
All installations must be in accordance with the regulations in force in the
country of use. These instructions must be handed to the user on completion of
the installation.
Installers and service engineers must be able to demonstrate competence and be
suitably qualified in accordance with the regulations in force in the country
of use. To ensure continued and safe operation it is recommended that the
appliance is serviced annually. The heater outlet/inlet must not be obstructed
during use.
Health and Safety
Sole liability rests with the installer to ensure that all site safety
procedures are adhered to during installation. Sole liability rests with the
installer to ensure that protective safety wear such as hand, eye, ear and
head protection is used during installation of the product. Do not rest
anything especially ladders against the product.
Standards
Units conform to the European electrical standard BS EN 60335-2-30
Electrical Supply
The electrical supply is 230/240V single phase, Neutral and Earth. The maximum
cable inlet size is 4mm². It is recommended that the electrical supply to the
base unit in the heater is via an appropriately switched isolator in
accordance with the regulations in force in the country of use and must be via
a fused isolator having a contact separation of greater than 3mm on all poles.
There are no exceptions. BMS control, time switches, room thermostats and door
interlocks can be installed at the discretion and responsibility of the
installer. All units must be wired in accordance with I.E.E regulations for
the Electrical Equipment of Buildings and the installer should ensure that a
suitable isolating switch is connected in the mains supply.
Controller SL
models
The HE7230SL, HE7245SL, HE7260SL heaters are supplied without a controller.
The SL
models will not work without the controller. See section 5.1 for more
details.
Controller RX
models
The HE7230RX, HE7245RX, HE7260RX heaters are supplied without a controller.
The RX
models will not work without the CRXSL. See section 5.2 for more
details
Location
All units should be installed horizontally. It is recommended that the ceiling
heater is installed within the ceiling void or roof space. Care must be taken
to allow complete free air movement into the inlet grilles of the unit to
ensure the correct working operation of the heater. If the HE7230SL/RX or
HE7245SL/RX heaters are mounted close to the wall or corner the discharge
opening should be facing the wall. The minimum distance from the wall or
corner is 0.8m or 1.2m for the HE7260SL/RX.
Clearance distances
It is recommended that a minimum clearance of 50mm is allowed around the case and 30mm above the heater. The clearance allows for cable entry and prevent combustible surfaces from overheating. The minimum mounting height (floor to grille) is 2.2m for the HE7230SL/RX, HE7245SL/RX and 2.5m for the HE7260SL/RX. The recommended mounting height is 2.5m for the HE7230SL/RX, HE7245SL,RX and 3m for the HE7260SL/RX.
Dimensions
Installation Details.
Mounting
The Claudian recessed ceiling heaters are designed to fit in place of a
standard 600mm ceiling panel. IT IS ESSENTIAL THAT THE CEILING FRAME IS
ADEQUATE TO SUPPORT THE WEIGHT OF THE HEATER, OR THAT THE HEATER IS
INDIVIDUALLY SUPPORTED. THERE IS PROVISION ON THE HEATER FOR CHAIN OR WIRE,
SUPPORT OR MOUNTING. The weight of the HE7230SL/RX, and HE7245SL/RX is 7kg The
weight of the HE7260SL/RX is 10k It is the sole responsibility of the
installer to ensure that the points of attachment to the building are sound.
Care must be taken to allow complete free
air movement into the inlet grilles of the unit to ensure the correct working
operation of the heater. Carefully unpack the unit. The unit is supplied with
a length of the self-adhesive foam strip. This can be cut into lengths and is
to be laid on the 4 sides of the ceiling frame. This will ensure that the unit
assembly is free from vibration. The discharge grille and diffuser assembly
can now be fitted into the ceiling frame
Mounting supports
Air discharge of HE7230SL/RX and HE7245SL/RX
Air discharge of HE7260SL/RX
The wire or chain used to mount the heater can be attached to 4 of the M6 studs or the 4 x M6 threaded inserts as shown in diagram.
Electrical Connections
Electrical Connections.
These units are suitable for connection to a 230/240 Volt 50 Hz single-phase supply. The appliance shall be connected to the supply via an appropriate switched fused double pole isolator having a contact separation of greater than 3mm. Test for correct operation and refit the cover. For connection to the mains supply, it will be necessary to open the terminal cover at the side/ back of the unit to connect the supply from the controls prior to refitting the cover. Wire in accordance to the wiring diagrams. For safety reasons, a sound earth connection must always be made to the unit before it is put to use. The unit should be wired in accordance with IEE Regulations for the Electrical Equipment o Buildings.
Electrical connections for SL and RX models
- Heater with terminal cover open
- Terminal cover detail
Operation
SL models
The heaters HE7230SL, HE7245SL and HE7260SL can be controlled by CONSORT CRXSL
or any SL wireless controller. Each CRXSL or SL controller can control any
number of heaters providing they are in the RF range. For more details please
follow the instructions supplied with the controller.
RX Models
The heaters HE7230RX, HE7245RX and HE7260RX can be controlled by CONSORT
wireless controller CRXSL. The heaters will not work without a controller.
Each controller has unique identification code, it can control an unlimited
number of heaters in the same room and will not interfere with other
controllers within the building. For more details please follow the
instructions supplied with the controller.
Servicing & Maintenance.
Maintenance
ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE COMMENCING ANY MAINTENANCE ON THIS HEATER. To obtain the best results from the heater, it is essential to avoid the accumulation of dust and dirt within the unit on the air inlet and discharge grilles. For this reason, regular cleaning is necessary. Cleaning of the fan is best carried out with a soft brush. The product should be serviced annually. Servicing shall be undertaken by a competent person.
General
If the heater does not operate a competent service engineer should be called
to identify the nature of the fault. All heaters are fitted with motor thermal
protection. Other faults in relation to the element, motor and wiring should
be identified using conventional fault finding techniques. In the event that
electrical components are
replaced, please ensure that electrical safety checks in accordance with the
regulations in force in the country of use are undertaken.
Thermal cut-out
The units are protected from overheating in the event of fan failure or an
obstruction of the free airflow, by thermal cutouts. If this happens the
thermal cut outs switch off the appliance. The appliance will not operate
until the heater is disconnected from the mains supply and it has cooleddown.
If this fault occurs again, refer to the section ‘6.4 fault finding’. Fault
Finding If the heater will not operate, disconnect it from the mains and
arrange for a certified electrician to attend and investigate the reason.
Replacing the Fan Heater
- Remove the grille.
- Disconnect the internal wiring from the blower
- Remove the four screws fixing the fan heater assembly to the back of the case.
- The fan heater assembly can now be eased forward and removed from the heater case.
- Fit replacement fan heater and reassemble in reverse order.
Spares
It is essential when ordering spares or replacement parts to state the model
number and the serial number on the rating label fixed to the side of the unit
below the terminal cover. In the interest of progress the Company reserve the
right to vary specifications from time to time without notice. The material
listed is offered subject to the Company’s General Conditions of Sale, a copy
of which can be obtained on request.