hygiena Allergen RM 800 Hazelnut Detection Kit User Manual

June 17, 2024
Hygiena

hygiena Allergen RM 800 Hazelnut Detection Kit

Specifications

  • Product Name: Hazelnut Detection Kit
  • Product No.: KIT230059
  • Revision: A, December 2023
  • PCR kit for the qualitative detection of hazelnut DNA using real-time PCR instruments
  •  Kit for 64 reactions
  • For food testing purposes
  • FOR IN VITRO USE ONLY

foodproof®

Hazelnut Detection Kit Ready Reference Guide

Product No. KIT230059

PCR kit for the qualitative detection of hazelnut DNA using real-time PCR instruments.
Before starting, it is strongly recommended to read the entire product manual available on our website.

PROGRAM SETUP

Program your real-time PCR instrument before setting up the PCR reactions.

Select the following channels:

FAM (hazelnut) and HEX (Internal Control).

hygiena-Allerge-800-Hazelnu-Detection-Kit-01For some real-time PCR instruments, the probe quencher as well as the use of a passive reference dye must be specified. This kit contains probes with a non- fluorescent “dark” quencher and no passive reference dye.

DATA INTERPRETATION

Verify results of positive (Control Template) and negative (H2O) controls, before interpreting the sample results. Always compare samples to positive and negative controls. Review data from each channel and interpret results as described in the table.

hygiena-Allerge-800-Hazelnu-Detection-Kit-2

PREPARATION OF THE PCR MIX

Take appropriate precautions to prevent contamination, e.g., by using filter tips and wearing gloves. Thaw reagents, mix (do not vortex!) and briefly spin vials before opening.

  1. ADD PCR MIX
    Pipet 20 µL of Master Mix into each strip or plate well (n samples + 2 controls).

  2. ADD SAMPLES AND CONTROLS
    Pipet 5 µL of samples, Negative Control (colorless cap) or Control Template (purple cap) into respective wells.
    OPTIONAL: STANDARD CURVE
    For quantification, prepare the standard curve.
    Please refer to Allergen RM 800 (Product No. KIT230009) product manual.

  3. SEAL
    Seal strips/plate accurately.
    hygiena-Allerge-800-Hazelnu-Detection-Kit-4

  4. CENTRIFUGE
    Briefly spin strips/plate in a suitable centrifuge.

  5. START REAL-TIME PCR RUN
    Cycle samples as described above.

foodproof®
Hazelnut Detection Kit

KIT230059
Kit for 64 reactions Store kit at -15 to -25 °C
For food testing purposes FOR IN VITRO USE ONLY Made in Germany

Hygiena® | Camarillo, CA 93012 USA | diagnostics.support@hygiena.com | www.hygiena.com