INDUSTRIAL PLUG
-
67351 50AMP 125/250V 3-Pole 3-Wire NEMA 10-50P
-
65351 50AMP 125/250V 2-Pole 3-Wire Grounding NEMA 6-50P
-
66351 50AMP 125/250V 3-Pole 4-Wire Grounding NEMA 14-50P
-
67352 30AMP 125/250V 3-Pole 3-Wire NEMA 10-30P
-
65352 30AMP 125/250V 2-Pole 3-Wire Grounding NEMA 6-30P
-
66352 30AMP 125/250V 3-Pole 4-Wire Grounding NEMA 14-30P
Installation
-
WARNING: TO AVOID FIRE, SHOCK, OR DEATH, UNPLUG CORD OR TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
-
The provided interchangeable blade enable the plug to be converted between 30amp type and 50amp type.
-
Prepare Cord: Strip cord jacket according to STRIPPING DIAGRAM (P1)
-
Connect Wires: Twist all strands of each conductor tightly together and insert into proper terminal. Hold each conductor in terminal housing, tighten each terminal screw to 1.6 N.M(≈14.2 in. lbs )of Max torque, firmly over conductor.
-
14-50P as an example: Connect the green wire to the U-shaped blades. Connect the white wire to the straight blade opposite the U-shaped blade, connect the other 2 wires to the remaining 2 blades. Make sure the blade wire clamps face toward to the outside and wiring position is correct (P2). please refer to the Wire Diagram below for wiring details.
-
Install the cord clamp and tighten the screws.
-
Put the cover back to the plug, tighten the surface mounting screws
Wire Strip Length = 5/8”
Cord Range: #10/3 SRD to #4/3 SRD, 8.in.dia.max
Wire Diagram