- Product Name: 961243-C-GFCI and 961243-S-GFCI One Gang Pop-up Floor Box Assembly with 20A GFCI Tamper Resistant Duplex Receptacle
- Description/Features: One gang pop-up floor box with 20 amp GFCI tamper-resistant duplex receptacle
Product Usage Instructions
Installation Instructions
WARNING: Turn the POWER OFF at the circuit breaker before installing the Floor Box.
Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only, or equivalent.
Floor Box Installation
Before Installation: Ensure there is sufficient depth & space below the subfloor.
- Step 1: For carpeted floors: Cut out a section of carpet smaller than the size of the cover.
- Step 2: (Refer to wiring directions below)
Wiring Directions
- Insert the HOT wire to the LINE terminal and tighten the screw.
- Insert the NEUTRAL wire to the NEUTRAL terminal and tighten the screw.
- Insert the GROUND wire to the GREEN terminal and tighten the screw.
Warranty Information
For warranty information, please refer to the documentation provided with your purchase.
FAQ
- Q: Can I install this product without professional help?
- A : It is recommended that a qualified electrician performs the installation to ensure safety and compliance with regulations.
SPECIFICATIONS
Cover Material
961243……………………………………………………………………………Brass(C) or Nickel-Plated Brass(S)
Receptacle Rating…………………………………………………………………………………………..20A 125VAC
Box Material……………………………………………………………………………………………..Galvanized Steel
Knockout size…………………………………………………………………………………………………1/2″ and 3/4″
Adjustable Height………………………………………………………………………………………….up to 1″ depth
DESCRIPTION/ FEATURES
Included is a One Gang pop-up floor box with 20 amp GFCI tamper-resistant duplex receptacle
- Compact and stylish design with adjustable height function metal box with the choice of Brass(C) or Nickel-Plated Brass(S).
- Corrosion-resistant hardware ensures a long life span and reliable performance. Easy access to power when you need it. Snap the cover closed when not in use.
- Used for carpet and wood floors. Also great for countertop applications.
WARNING
- Turn the POWER OFF at the circuit breaker before installing the Floor Box
- Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure power is off before wiring the device. Use copper wire only, or equivalent.
- NOTES:
- 10-12 AWG Stranded or Solid Copper wire is recommended.
FLOOR BOX INSTALLATION
- Before Installation
- Ensure there is sufficient depth & space below the subfloor.
- Step 1
- For carpeted floors:
- Cut out a section of carpet smaller than the size of the cover.
- For wood sub-floors and finished hardwood floors:
- Tape the template on the area you want to place the floor box.
- Use a knife to cut the outline of the box. Start with the ears and move inwards.
- Following the outline, cut the box shape without the ears completely through the subfloor or hardwood floor.
- Following the outline, cut 3/8″ deep into the subfloor or hardwood for the mounting ears.
- Using a router is recommended
Step 2
- Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram.
- Use the proper connector/ clamp at the knockouts to secure the wires and to avoid accidental wire stripping.
- Secure the box to the opening using wood screws.
WIRING DIRECTIONS
- Insert the HOT wire into the LINE terminals and tighten the screw.
- Insert the NEUTRAL wire into the NEUTRAL terminal and tighten the screw.
- Insert the GROUND wire into the GREEN terminal and tighten the screw.
WARRANTY INFORMATION
This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. ALL claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warrantyor any other legal theory.