LUXCOL 14383119 Twin Air Mattress with Built in Pump Instruction Manual

June 17, 2024
LUXCOL

LUXCOL 14383119 Twin Air Mattress with Built in Pump

LUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-fig-
product

Thank you for choosing a LUXCOL Air Mattress We are committed to providing quality, reliable products to bring more convenience to your life. Your satisfaction is our only pursuit. If you have questions or need assistance, please EMAIL our qualified customer services at luxcol@outlook.com. We hope you enjoy your new product!

SAFETY INSTRUCTIONS

READ CAREFULLY!
When installing and using this air mattress with a built-in electric pump, there are basic safety precautions that should always be followed:

  • Always unplug the air mattress when not in use.
  • Close supervision is necessary when the air mattress is being used by or near children or people with limited mobility.
  • Infants have suffocated on inflatable mattresses. Never place an infant of 15 months or younger to sleep on this inflatable air mattress. Infants can suffocate on an underinflated or deflated mattress, on bedding, by co-sleeping with another person, or by being trapped between the mattress and bed frame or between the mattress and a vertical surface.
  • Children can be trapped between the inflatable mattress and an adjacent vertical surface. Provide at least a shoulder-width space between the inflatable mattress and adjacent vertical surfaces such as walls, dressers, or other objects.
  • DO NOT exceed the weight limit for this device: 5501b (Twin Size)/ 6501b (Queen Size).
  • DO NOT use the air mattress outdoors or in damp areas. This product is for household use only.
  • This air mattress is only to be used for its intended purpose as described in this manual.
  • DO NOT block the air openings while the device is in operation. Always keep air openings free of lint, hair, and other small objects. Never drop or insert objects into any of the openings.
  • DO NOT use aerosols or administer oxygen when the air bed is in operation
  • DO NOT use the air mattress to support video equipment such as televisions or computer monitors.
  • DO NOT use the air mattress around people using medical devices.
  • Keep away from sharp objects that may damage the product.
  • Always keep the inflatable mattress fully inflated when in use.
  • DO NOT operate the pump in enclosed spaces that are not well-ventilated. Always ensure there is at least two feet of clearance from any wall or object while the pump is in operation.
  • DO NOT place the air mattress on heated surfaces. Fires may occur if the air bed touches or is covered by, flammable materials, including curtains, draperies, cardboard, or plastics while in operation.
  • DO NOT operate the pump in the presence of explosive and/or flammable fumes.
  • DO NOT place any part of the pump or cord in or under water or other liquid.
  • Keep the power cord away from all heat sources.
  • If the power cord is damaged, stop use immediately.
  • DO NOT disassemble the pump casing for any reason. Contact us for assistance.
  • If inflating the air bed manually, use a low-pressure inflator. Do not overinflate.

WARNING: This device is operated with an electrical air pump that is thermally protected. The pump does not contain parts that can be repaired or serviced. Opening the pump casing may expose you to the risk of electric shock. If you have any issues with the electrical pump upon its arrival, please email luxcol@outlook.com for assistance.

ATTENTION: PVC Material
The air mattress is made from PVC material. PVC will naturally stretch and expand during use. After being inflated and/or having been slept on for several days, the air mattress may lose some of its initial firmness due to the PVC expanding. This is normal and is not the result of air leaking from the air mattress. Add air to the air mattress through the built-in air pump to regain your desired firmness level.

OVERVIEW

LUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-
fig-9

  • Air mattress (A)
  • Power cord (B)
  • Manual inflation/ deflation valve (C)
  • Control dials (D)
  • Air vent (E)
  • Power cord storage compartment (F)
  • Carry bag (G)
  • Repair patches (H)

Specification

PRODUCT SPECIFICATION                         TWIN QUEEN

Inflated Size (approJ<| )| 7SJ<39x18in| 80x60x18in
Max. Weight Capacity (approx.)| SS0lbs| 6S01bs
Product Weight (approx:.)| 14 lbs| 20lbs
Voltage (US)| 110·120V| 110| 120V
Materials| Eco FriendlyPVC• Aodking| Eco-friendly PVC• Flocking

SET-UP

  1. Remove the air mattress from its packaging and unfold it so the felt side is facing up.
  2. Open the power cord storage compartment and connect the power cord to an electrical outlet. Turn the power outlet on.LUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-fig-10
  3. Turn both the control dials clockwise until the marker points towards “INFLATE” to pump air into the air mattress.
  4. Turn both the control dials anti-clockwise to “OFF” when the air bed has reached the desired firmness. Ensure the arrow points to the “OFF” position to prevent air loss.
  5. Lie on the air mattress to test the firmness.
  6. If you wish to make further adjustments, the control dials can be turned clockwise to further inflate or turned anti-clockwise until the marker points towards “DEFLATE” to let air out of the air mattress. Turn the control dials back to “OFF” after achieving the desired firmness level.
  7. Unplug the power cord and store it back into the power cord storage compartment. The air mattress is now ready for use.

Notes:

  • After inflating the air mattress for the first time, it is recommended to wait for 8-12 hours before using it so the seams can buffer.
  • It is normal for the mattress to lose a small amount of air after being fully inflated.
  • During initial use, the air mattress may soften and require additional inflation to maintain the desired firmness. This is normal.
  • If the air mattress is intended to be used for an extended period, inflate the air bed for 10-15 seconds every day to maintain its firmness

Deflation and storage

  1. Plug the power cord into a power outlet and turn both the control dials anti-clockwise to “DEFLATE”.
  2. After the air mattress is completely deflated, turn both the control dials to “OFF”. Unplug the power cord and place it back into the power cord storage compartment.
  3. Lay the air mattress felt-side up and fold the mattress into thirds, then roll up the mattress to release any remaining air.
  4. Store the mattress in a cool dry place.

Manual inflation

  1. Open the manual in action valve cap and connect an air pump or hose (NOT included) to the valve.
  2. Turn on the air pump or hose and inflate to the desired firmness. Close the valve with the valve cap. The air mattress is ready for use.

Manual deflation

  1. Fully open the manual deflation valve to release all the air from the air mattress.

IMPORTANT TIPS

Before using your bed

  • When using the bed for the first time, please leave the bed for 2 hours after inflation to let the material stretch out and then top up the air.
  • After inflation, make sure the pump is off and the manual valve is fully closed.
  • After long-term use, you may find that the material becomes more stretched and you may need to inflate the bed for addi­tional time before using it.
  • All inflatable beds have some natural leakage. Top up the air once per week to keep the same level of firmness.

First inflation

HOW TO CHECK AIR LEAKAGE AREA

  • Notice
    Check if the valve and pump are closed.

  • Method1
    inflate the bed and check for air ‘8.lks by hand. The air leak is well! you can feel a strong air stream coming out.

  • Method 2
    Inflate the bed and carry it to the yard. Prepare a water faucet or a bucket of water and then slowly pour it over the whole mattress to see where the bubbles come out.

  • Method 3
    Inflate the bed, then dip thick soap foam with a soft brush and evenly smear it on the inflatable bed, one area at a time. If you see big bubbles popping out or hear a squeaking sound, that is where air leaks are formed. Mark the leak with a permanent marker once you locate it.

HOW TO FIX LEAKS

METHOD 1: Repair patch (recommended)
Deflate the air mattress and then clean the area around the puncture. Trim the patch to an oval shape and ensure it is big enough to cover the puncture. Pull off the back paper from the patch and then place it over the puncture. Press the patch down firmly and ensure there is no trapped air under ii.
METHOD 2:PVC repair (You need to buy it from somewhere else)
NOTE: Please cut off the power belo,e deaning and finding/preparing holM.

  1. locate the air leakage point, and dean the area with a diameter of 6cm around it.
  2. Trim the patches into smaller pieces that are about 1-1.SCM larger than the leak pointLUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-fig-1
  3. Apply glue evenly to the ma, ked puncture and 10 tho p;,!DLC<. (Gluo need, lo be purchased by yourself.)
  4. Stick patches on the mattress.LUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-fig-2
  5. Leave the glue to dry for 5-10 minutes. Use a hair dryer for a short time to help the glue to dry.
  6. Use a flat object to press down on the repair patch. Wait 24 hours before inflating the bed.LUXCOL-14383119-Twin-Air-Mattress-with-Built-in-Pump-fig-3

CLEANING & CARE

  • clean the air mattress, use a mild soap solution and water.
  • Do not use chemicals to clean the air mattress.
  • If the air mattress needs to be repaired, use the repair patches provided and common PVC repair glue (NOT included).
  • When not in use, store the mattress in a cool, dry place.

WARRANTY

LUXCOL is devoted to providing only high-quality air mattresses featuring premium materials and advanced technology. However, in exceptional cases, the product may have malfunctioned due to manufac­turing defects. That is why we offer a full one (1) year warranty from the date of original retail purchase. This limited warranty covers any defects under normal use. This warranty does not apply to the following:

  • If the product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, or has not been installed, maintained, or operated following the furnished written instructions.
  • Tears, punctures, or any damage caused by improper installation, moving, or use.
  • Normal wear and tear.
  • Fabric stains, soiling, or burns.
  • The unit is used as a rental or commercial business.

Sign up for Extra 1-VEAR Warranty
To serve our customers better, we sincerely invite you to complete the following information and email it to: luxcol@outlook.com

LUXCOL AIR MATTRESS REGISTRATION AND INFORMATION CARD

  • Order Number:………………………………… Name: ………………………………..
  • Address:……………………………….City/State/Zip:…………………………………
  • Phone:……………………………………………………………………………………………
  • Purchase Date:…………………………….. Purchase From:……………………………
  • Model:………………………………………………………………
  • Twin………………………………………………………………
  • Queen……………………………………………………………

Customer Support

We hope this user manual has given you the assistance needed for a simple set- up. For any additional assistance you may require, please contact us by email at luxcol@outlook.comand we will help you find a solution.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals