Specifications
- Model: JC15G-15
- Product: Automatic Booster Pump
- Power: 120W
- Voltage/Hz: 110/60
- Max. Flow: 25 L/min
- Max. Head: 15m
- Speed: 3500 r/min
Product Usage Instructions
Installation
Before operating the pump, carefully follow the installation guidelines below:
- Ensure the motor is not installed upside down or tilted down to prevent water leakage and potential short circuits.
- Install the pump close to the water source with a short water suction pipeline to prevent air leakage.
- If installing the pump far from the well, consider the maximum length between the pipe and well based on suction head.
- Install a filtration device at the end of the piping when operating near wells or rivers to prevent sand absorption.
Usage Occasions
The water pump is suitable for various applications including water supply and drainage for aquaculture, gardens, hotels, and more. Ensure clean water conditions for pressurized water supply.
Maintenance
Regular maintenance is essential for optimal performance:
- Do not run the pump dry to prevent damage to the seal.
- Clean the filter screen monthly to ensure proper functioning.
FAQ
Why is my pump not discharging water?
Possible reasons and solutions include:
- Fault: Air leakage at the inlet pipe interface
- Solution: Fasten the pipeline-interface
- Fault: Damaged seals
- Solution: Replace the seal
- Fault: Bottom valve and impeller are blocked or damaged
- Solution: Remove sundries or replace the bottom valve and impeller
- Fault: Insufficient water supply
- Solution: Select a place with sufficient water source
- Fault: The power supply voltage is too low
- Solution: Adjust the power supply voltage to the rated value
Technical Support and E-Warranty Certificate www.vevor.com/support
AUTOMATIC BOOSTER PUMP INSTRUCTION MANUAL
We continue to be committed to provide you tools with competitive price. “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.
MODEL: JC15G-15
NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us:
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.
Please read this guide carefully before you use this type of pump.
INSTALLATION SKETCH MAP
It is forbidden to install the motor upside down or tilt down to prevent water leakage from entering the motor and causing a short circuit and burning the motor.
USE OCCASION
- Please don’t install the pumps at the outlet of the water heater
- Please don’t install the taps at the inlet of the water pumps
WORKING CONDITION
- Medium transportation temperature: 2℃~+95℃
- Max circumstance temperature: +40℃
- Medium condition: clean, no solid substance, no mineral & oil substance, no stickiness.
- Chem. condition: near neutral, non-cauterization, non-explosion similar water (glycol max-content: 30%).
- If you want to use other kinds of liquids, please consult the factory.
- Max working pressure: 3 bar
- The pump must be working at a rated voltage range of ±10%. If the voltage is too low, the pump will come out low speed or hardly start up, easily heating, lower head and pressure.
PURPOSE AND INSTALLATION PRECAUTIONS
- The water pump is used for water supply and drainages of rivers, wells, boilers, etc., such as aquaculture, gardens, hotels, and pots. The boiler, canteen, high-rise building, and other pressurized water supply conditions are clean water. The water pump should be close to the water source, the water suction pipeline shall be as short as possible, and no air leakage is allowed. Otherwise, water cannot be absorbed.
- The water pump shall be installed directly above the well as far as possible, but when the water pump can only be installed far away from the well, the maximum length between the pipe and the well depends on the suction head.
- Suction height is subject to dry season
* When the water pump is installed together with the well and river, it is easy to absorb sand, and the end of the piping needs to be installed with a filtration device. Filters are available at the pump sales office.
- It is strictly forbidden to run the water pump dry to avoid damaging the seal and causing the water pump to not work normally.
- The filter screen needs to be cleaned every 1 month.
MAIN FEATURES
JC pipeline pump is a high-pressure vortex pump. The motor and pump are coaxial, vertical, and horizontal dual-purpose integrated models. This series of products has two types of structure, namely ordinary type and automatic type. The common type is composed of a motor, main shaft, mechanical seal, impeller, pump body, fan blade, fan cover, wire box, and other parts. The automatic type consists of a common type equipped with an automatic water flow control device. The automatic control device is organically connected to the water pump so that the start and stop of the water pump are all controlled by the valve of the faucet.
SPECIAL WARNING
Before use, the pump must be reliable earth touch. Don´t change the three-core wiring plug to avoid power leakage. To make sure everything is safe, please u must install some security measures, such as the power leakage broker or electric shock blocker and so on.
- Earth wiring and nil wiring must be separated. If there is no reliable earth wiring, the accident will be no business with us.
This type of water pump´s plug feet, if “L” is Live Wiring, “N” is Nil Wiring, and the longest one is “E” earth touch wiring. Customers must pay attention to the connection to the plug when they install the three-core socket.
Here we absolutely forbid u to unite the Nil Wiring and Earth Wiring together, which can make power leakage dangerous.
- Don´t use a blanket to cover the motor or the pumps. Keep ventilation to avoid fire danger.
- If you install our pump outdoors, please u should do some protection measures. Or it will decrease the using life span because of the sun-baked and raining. Worst, it can cause an electric shock accident. If you install our pump indoors, please avoid water spilling to make an electric shock; don´t install it inside the bathroom to avoid the cream and water going inside.
- After a few years of normal use, if you hear any sound in the motor, please replace the internal shield components timely to prevent the danger of electric shock hazard by water leakage.
PRECAUTION
- When connecting to the power supply, let the pump work for several seconds to inspect whether the start-up is normal or not. But don’t let the pump work with no water for a long time to affect the ceramic bearing span, special the self-auto water pump. In case of no water suddenly, u should pay more attention to avoid unnecessary loss.
- Pls pay attention to the water drop on the wood floor or easily moisture goods when exhausting the air or maintenance.
- Don’t touch to avoid scald when our pump using in the heating system. The wiring materials must be heating-resistant.
- Before installation, make sure the pipeline is welding well and clean. If there have foreign substances, welding clinker, or dirt, they will damage the water pump.
- The place where to install the pump should be convenient for maintenance and change.
- We suggest that you pls separately install the check valve at the inlet or outlet for maintenance. Then it can avoid the leaking water drop to the water pump and the junction box.
- Current flow direction should be the same as the arrow on the pump.
- When the direction of the junction box isn’t right, u can lose the hexangular screw and return the motor to the right position. Pls don’t damage the rubber gasket, then re-tighten the screw and check whether the seal gasket is ok or not.
PERFORMANCE PARAMETER
INSTALLATION DIMENSION
USUAL FAULT & MEASURE
- If you want to mend or maintain, please close the two-end taps and let the pump cool down. Then you can maintain, avoiding scalding or the steam or hot liquid, which come out from the inside pressure system.
- Cut off the power supply.
- Only expert staff can install or perform maintenance.
- If the above measures are not working, pls contact your local dealer or directly contact our factory.
PRODUCT ACCESSORIES
- Electric pump;
- Water pipe sealing tape *1;
- DN20 to DN15 loose copper connector *2;
- DN20 to DN15 water flow switch *1;
- Filter screen.
Address: Baoshanqu Shuangchenglu 803long 11hao 1602A-1609shi Shanghai
Imported to the USA: VEVOR STORE INC, 9448 RINCHMOND PL #E RANCHO CUCAMONGA, California, 91730 United States of America