  1. Connect the positive supply wire (typically black or the smooth, unmarked side of the two-conductor cord) to the positive
    fixture lead with an appropriately sized twist-on connector.

  2. Connect the negative supply wire (typically white or the ribbed, marked side of the two-conductor cord) to the negative fixture lead.

  3. Refer to the grounding instructions below to complete all electrical connections.

Outdoor Fixtures

  1. Connect the positive supply wire (typically black or the smooth, unmarked side of the two-conductor cord) to the positive fixture lead with an appropriately sized twist-on connector.
  2. Connect the negative supply wire (typically white or the ribbed, marked side of the two-conductor cord) to the negative fixture lead.

Note: For both indoor and outdoor fixtures, it is recommended to consult a qualified electrician or local authorities for code requirements and to ensure proper installation.

Mounting Instructions

start here

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.
  4. To begin installation of your fixture it will first be necessary to remove the mounting plate (A) from the backplate (B). This is accomplished by first removing the four screws(C), Set screws in a safe place for use later.
  5. Next attach mounting plate (A) to junction box (J) with two screws (D), NOT PROVIDED.
  6. Make all necessary electrical connections following instruction sheet IS-18 provided.
  7. After all connections are made, tuck wires into junction box (J) and slip backplate (B) over mounting tabs (T) and align threaded holes in tab (T) with holes (H) in backplate (B).
  8.  Thread in screws (C) removed earlier, and tighten to secure fixture to wall.

DRAWING 1 – MOUNTING

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUC-TIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

DRAWING 2-Shade INSTALL

SHADE INSTALLATION

  1. Place shade (1) over socket (3)
  2. Use socket ring (4) to secure shade (1)
  3. Lamp fixture with appropriate bulb (2)
  4. FIxture can now be powered on

wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions
Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections
    HINKLEY-46450BK-Fenwick-Large-Sconce-01

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Drawing 3 – Post-Mount

grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with an appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing.

H I N K L E Y 33000 Pin Oak Parkway, Avon Lake, OH 44012 8 00.446.5539 / 440.653.5500 hinkley.com